Search USGS⌕ Search

Geology topics

W.R. Gala

Publications and source records attributed to W.R. Gala.

2 recordsLinked to original sources

Overview and comparison of lipid-containing semipermeable membrane devices and oysters (Crassostrea gigas) for assessing organic chemical exposure

We performed 20-d, flow-through exposures of lipid-containing semipermeable membrane devices (SPMDs) and Pacific oysters ( Crassostrea gigas ) to three concentrations (nominally 10, 100, and 250 ng/L) of a diverse mixture of polycyclic aromatic hydrocarbons (PAHs). Exposure water was seawater free of particulates larger than 0.1 μm. The results of these controlled laboratory studies demonstrated that SPMDs and oysters concentrate the same chemicals but that the relative amounts accumulated are different. For oysters, the 20-d mean (across treatments) concentration factors (CFs) of test compounds with log K ow ≤ 4.8 were much lower (4.0- to 20-fold lower) than those of the same compounds in SPMDs. In contrast, the 20-d CFs of PAHs with log K ow ≥ 5.6 in oysters from the low-level treatment were higher than the corresponding CFs for SPMDs. The CFs of these compounds in oysters from the low-level treatment ranged from approximately 3.0- to 13-fold higher than those in oysters from the high-level treatment. This physiologically mediated difference in oyster CFs appears to be linked to active feeding in the low-level treatment and to apparent toxicity-induced cessation of feeding (i.e., valve closure) in the high-level treatment. Because CFs for these compounds in oysters were not independent of exposure concentrations, it follows that tissue levels were not proportional to exposure concentration. However, both sampling approaches have advantages and disadvantages, and the appropriateness of their use depends on the goals of a given study.

Environmental Toxicology and Chemistry↗

Determination of uptake kinetics (sampling rates) by lipid-containing semipermeable membrane devices (SPMDs) for polycyclic aromatic hydrocarbons (PAHs) in water

The use of lipid-containing semipermeable membrane devices (SPMDs) is becoming commonplace, but very little sampling rate data are available for the estimation of ambient contaminant concentrations from analyte levels in exposed SPMDs. We determined the aqueous sampling rates (R(s)s; expressed as effective volumes of water extracted daily) of the standard (commercially available design) 1-g triolein SPMD for 15 of the priority pollutant (PP) polycyclic aromatic hydrocarbons (PAHs) at multiple temperatures and concentrations. Under the experimental conditions of this study, recovery- corrected R(s) values for PP PAHs ranged from ???1.0 to 8.0 L/d. These values would be expected to be influenced by significant changes (relative to this study) in water temperature, degree of biofouling, and current velocity- turbulence. Included in this paper is a discussion of the effects of temperature and octanol-water partition coefficient (K(ow)); the impacts of biofouling and hydrodynamics are reported separately. Overall, SPMDs responded proportionally to aqueous PAH concentrations; i.e., SPMD R(s) values and SPMD-water concentration factors were independent of aqueous concentrations. Temperature effects (10, 18, and 26 ??C) on Rs values appeared to be complex but were relatively small.The use of lipid-containing semipermeable membrane devices (SPMDs) is becoming commonplace, but very little sampling rate data are available for the estimation of ambient contaminant concentrations from analyte levels in exposed SPMDs. We determined the aqueous sampling rates (Rss; expressed as effective volumes of water extracted daily) of the standard (commercially available design) 1-g triolein SPMD for 15 of the priority pollutant (PP) polycyclic aromatic hydrocarbons (PAHs) at multiple temperatures and concentrations. Under the experimental conditions of this study, recovery-corrected Rs values for PP PAHs ranged from ???1.0 to 8.0 L/d. These values would be expected to be influenced by significant changes (relative to this study) in water temperature, degree of biofouling, and current velocity-turbulence. Included in this paper is a discussion of the effects of temperature and octanol-water partition coefficient (KOW); the impacts of biofouling and hydrodynamics are reported separately. Overall, SPMDs responded proportionally to aqueous PAH concentrations; i.e., SPMD RS values and SPMD-water concentration factors were independent of aqueous concentrations. Temperature effects (10, 18, and 26??C) on RS values appeared to be complex but were relatively small.

Environmental Science & Technology↗