Search USGSSearch

Geology topics

Travis Kropuenske

Publications and source records attributed to Travis Kropuenske.

3 recordsLinked to original sources

Absolute radiometric calibration evaluation of Uncrewed Aerial System (UAS) Headwall and MicaSense sensors and improving data quality using the Empirical Line Method

The use of Uncrewed Aerial Systems (UASs) for remote sensing applications has increased significantly in recent years due to their low cost, operational flexibility, and rapid advancements in sensor technologies. In many cases, UAS platforms are considered viable alternatives to conventional satellite and crewed airborne platforms, offering very high spatial, spectral, and temporal resolution data. However, the radiometric quality of UAS-acquired data has not received equivalent attention, particularly with respect to absolute calibration. In this study, we (1) evaluate the absolute radiometric performance of two commonly used UAS sensors: the Headwall Nano-Hyperspec hyperspectral sensor and the MicaSense RedEdge-MX Dual Camera multispectral system; (2) assess the effectiveness of the Empirical Line Method (ELM) in improving the radiometric accuracy of reflectance products generated by these sensors; and (3) investigate the influence of calibration target characteristics—including size, material type, reflectance intensity, and quantity—on the performance of ELM for UAS data. A field campaign was conducted jointly by the U.S. Geological Survey (USGS) Earth Resources Observation and Science (EROS) Center and the USGS National Uncrewed Systems Office (NUSO) from 15 to 18 July 2023, at the USGS EROS Ground Validation Radiometer (GVR) site in Sioux Falls, South Dakota, USA, over a 160 m × 160 m vegetated area. Absolute calibration accuracy was evaluated by comparing UAS sensor-derived reflectance to in situ measurements of the site. Results indicate that the Headwall Nano-Hyperspec and MicaSense sensors underestimated reflectance by approximately 0.05 and 0.015 reflectance units, respectively. While the MicaSense sensor demonstrated better inherent radiometric accuracy, it exhibited saturation over bright targets due to limitations in its automatic gain and exposure settings. Application of the ELM using just two calibration targets reduced discrepancies to within 0.005 reflectance units. Reflectance products generated using various target materials—such as felt, melamine, or commercially available validation targets—showed comparable agreement with in situ measurements when used with the Nano-Hyperspec sensor. Furthermore, increasing the number of calibration targets beyond two did not yield measurable improvements in calibration accuracy. At a flight altitude of 200 ft above ground level (AGL), a target size of 0.6 m × 0.6 m or larger was sufficient to provide pure pixels for ELM implementation, whereas smaller targets (e.g., 0.3 m × 0.3 m) posed challenges in isolating pure pixels. Overall, the standard manufacturer-recommended calibration procedures were insufficient for achieving high radiometric accuracy with the tested sensors, which may restrict their applicability in scenarios requiring greater accuracy and precision. The use of the ELM significantly improved data quality, enhancing the reliability and applicability of UAS-based remote sensing in contexts requiring high precision and accuracy.

Remote Sensing

Validation of the geometric accuracy of airborne light detection and ranging data for eastern Iowa, 2019

A geometric accuracy assessment of lidar data collected in eastern Iowa in 2019 as part of the 3D Elevation Program (3DEP) was conducted. The assessment involved evaluating interswath accuracy, same surface precision, point density, absolute accuracy, and consistency with adjacent 3DEP datasets. The results demonstrate that the data meet or exceed the quality level 2 specifications outlined in the Lidar Base Specifications (LBS). Interswath and same surface precision values were within specified tolerances, with a root mean square difference of 0.03 meters for interswath vertical accuracy and 0.03 meters for same surface precision. Vertical accuracy in flat areas was excellent, with root mean square error values consistently below 0.10 meters. Horizontal accuracy assessments also showed good agreement between lidar and reference data. Point density generally exceeded the minimum requirement of 2 points per square meter, and the inter-project consistency assessment indicated good agreement between the Iowa lidar data and adjacent datasets.

Iowa

Implementing a dual-spectrometer approach for improved surface reflectance estimation

Surface reflectance measurement is an integral part of the vicarious calibration of satellite sensors and the validation of satellite-derived top-of-atmosphere (TOA) and surface reflectance products. A well-known practice for estimating surface reflectance is to conduct a field campaign with a spectrometer and a calibration panel, which is labor-intensive and expensive. To address this issue, the Radiometric Calibration Network, RadCalNet, has been developed, which automatically collects surface reflectance over several selected sites. Neither of these approaches can continuously track the atmosphere, which limits their ability to compensate for atmospheric transmittance change during target measurement. This paper presents the dual-spectrometer approach that uses a stationary spectrometer dedicated to continuously tracking changes in atmospheric transmittance by staring at a calibrated reference panel while the mobile spectrometer measures the target. Simultaneous measurement of the reflectance panel and target help to transfer calibration from the stationary spectrometer to the mobile spectrometer and synchronize the measurements. In this manner, atmospheric transmittance changes during target measurement can be tracked and used to reduce the variability of the target surface reflectance. This paper uses field measurement data from combined field campaigns between different calibration groups at Brookings, South Dakota, and Landsat 8 and Landsat 9 underfly efforts over Coconino National Forest, Arizona, and Guymon, Oklahoma. Preliminary results show that even in a clear sky condition, where atmospheric transmittance changes are minimal, the precision of target surface reflectance estimated using the dual-spectrometer approach is 2–6% better than the single-spectrometer approach. The dual-spectrometer approach shows the potential for a substantial improvement in the precision of the target spectral profile when the atmospheric transmittance is changing rapidly during field measurement. Results show that during non-optimal atmospheric conditions, the dual-spectrometer approach improved the precision of the surface reflectance by 50–60% compared to the single-spectrometer approach across most spectral regions. The ability to estimate surface reflectance more precisely using the dual-spectrometer approach in different atmospheric conditions improves the vicarious calibration of optical satellite sensors and the validation of both TOA and surface reflectance products.

Remote Sensing