Search USGS⌕ Search

Geology topics

Susan A. Koehnlein

Publications and source records attributed to Susan A. Koehnlein.

2 recordsLinked to original sources

Effects of small-scale vertical variations in well-screen inflow rates and concentrations of organic compounds on the collection of representative ground-water-quality samples

Because a water sample collected from a well is an integration of water from different depths along the well screen, measured concentrations can be biased if analyte concentrations are not uniform along the length of the well screen. The resulting concentration in the sample, therefore, is a function of variations in well-screen inflow rate and analyte concentration with depth. A multiport sampler with seven short screened intervals was designed and used to investigate small-scale vertical variations in water chemistry and aquifer hydraulic conductivity in ground water contaminated by leaded gasoline at Galloway Township, Atlantic County, New Jersey. The multiport samplers were used to collect independent samples from seven intervals within the screened zone that were flow-rate weighted and integrated to simulate a 5-foot-long, 2.375-inch- outside-diameter conventional wire-wound screen. The integration of the results of analyses of samples collected from two multiport samplers showed that a conventional 5-foot-long well screen would integrate contaminant concentrations over its length and resulted in an apparent contaminant concentration that was a little as 28 percent of the maximum concentration observed in the multiport sampler.

Ground Water↗

Sampling vadose-zone water for a volatile organic compound at Picatinny Arsenal, New Jersey

A new method of collecting samples of unsaturated-zone water for quantitative analysis for a volatile organic compound, trichloroethene (TCE), was compared to three other, previously described sampling methodologies in the laboratory and in the field. In the laboratory, prepared water samples containing TCE in a known concentration (20 µg/L) were sampled repeatedly by using each of the four methods to quantify method precision and accuracy. To compare the four methods in the field, unsaturated-zone water above a TCE-contaminated water-table aquifer was transferred from a depth of 2 m to land surface with 0.15-m-long suction lysimeters attached to 1.85-m lengths of stainless-steel tubing. Statistical analyses of the laboratory and field data indicate that the new method, which involves collecting the water samples in gas-tight glass syringes, is superior to the other three methods for the quantitative sampling and analysis of TCE on the basis of its high precision and accuracy and ease of use. This method was used to collect additional samples from the field site to quantify the spatial variability of TCE concentrations in the unsaturated-zone water. Results of analysis of variance of the data indicate that the spatial concentration variability is important, and that differences in TCE concentration are statistically significant for horizontal distances less than 3.6 m.

New Jersey↗