Search USGS⌕ Search

Geology topics

S. Hook

Publications and source records attributed to S. Hook.

2 recordsLinked to original sources

Effects of arctic temperatures on distribution and retention of the nuclear waste radionuclides 241Am, 57Co, and 137Cs in the bioindicator bivalve Macoma balthica

The disposal of radioactive wastes in Arctic seas has made it important to understand the processes affecting the accumulation of radionuclides in food webs in coldwater ecosystems. We examined the effects of temperature on radionuclide assimilation and retention by the bioindicator bivalve Macoma balthica using three representative nuclear waste components, 241 Am, 57 Co, and 137 Cs. Experiments were designed to determine the kinetics of processes that control uptake from food and water, as well as kinetic constants of loss. 137 Cs was not accumulated in soft tissue from water during short exposures, and was rapidly lost from shell with no thermal dependence. No effects of temperature on 57 Co assimilation or retention from food were observed. The only substantial effect of polar temperatures was that on the assimilation efficiency of 241 Am from food, where 10% was assimilated at 2 °C and 26% at 12 °C. For all three radionuclides, body distributions were correlated with source, with most radioactivity obtained from water found in the shell and food in the soft tissues. These results suggest that in general Arctic conditions had relatively small effects on the biological processes which influence the bioaccumulation of radioactive wastes, and bivalve concentration factors may not be appreciably different between polar and temperate waters.

Marine Environmental Research↗

ASTER preflight and inflight calibration and the validation of level 2 products

Describes the preflight and inflight calibration approaches used for the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER). The system is a multispectral, high-spatial resolution sensor on the Earth Observing System's EOS-AM1 platform. Preflight calibration of ASTER uses well-characterized sources to provide calibration and preflight round-robin exercises to understand biases between the calibration sources of ASTER and other EOS sensors. These round-robins rely on well-characterized, ultra-stable radiometers. An experiment field in Yokohama, Japan, showed that the output from the source used for the visible and near-infrared (VNIR) subsystem of ASTER may be underestimated by 1.5%, but this is still within the 4% specification for the absolute, radiometric calibration of these bands. Inflight calibration will rely on vicarious techniques and onboard blackbodies and lamps. Vicarious techniques include ground-reference methods using desert and water sites. A recent joint field campaign gives confidence that these methods currently provide absolute calibration to better than 5%, and indications are that uncertainties less than the required 4% should be achievable at launch. The EOS-AM1 platform will also provide a spacecraft maneuver that will allow ASTER to see the Moon, allowing further characterization of the sensor. A method for combining the results of these independent calibration results is presented. The paper also describes the plans for validating the Level 2 data products from ASTER. These plans rely heavily upon field campaigns using methods similar to those used for the ground-reference, vicarious calibration methods.

IEEE Transactions on Geoscience and Remote Sensing↗