Search USGS⌕ Search

Geology topics

R.C. Clark

Publications and source records attributed to R.C. Clark.

6 recordsLinked to original sources

Reproductive health of bass in the potomac, USA, drainage: Part 2. Seasonal occurrence of persistent and emerging organic contaminants

The seasonal occurrence of organic contaminants, many of which are potential endocrine disruptors, entering the Potomac River, USA, watershed was investigated using a two-pronged approach during the fall of 2005 and spring of 2006. Passive samplers (semipermeable membrane device and polar organic chemical integrative sampler [POCIS]) were deployed in tandem at sites above and below wastewater treatment plant discharges within the watershed. Analysis of the samplers resulted in detection of 84 of 138 targeted chemicals. The agricultural pesticides atrazine and metolachlor had the greatest seasonal changes in water concentrations, with a 3.1 - to 91 -fold increase in the spring compared with the level in the previous fall. Coinciding with the elevated concentrations of atrazine in the spring were increasing concentrations of the atrazine degradation products desethylatrazine and desisopropylatrazine in the fall following spring and summer application of the parent compound. Other targeted chemicals (organochlorine pesticides, polycyclic aromatic hydrocarbons, and organic wastewater chemicals) did not indicate seasonal changes in occurrence or concentration; however, the overall concentrations and number of chemicals present were greater at the sites downstream of wastewater treatment plant discharges. Several fragrances and flame retardants were identified in these downstream sites, which are characteristic of wastewater effluent and human activities. The bioluminescent yeast estrogen screen in vitro assay of the POCIS extracts indicated the presence of chemicals that were capable of producing an estrogenic response at all sampling sites. ?? 2009 SETA.

Environmental Toxicology and Chemistry↗

Chemical and toxicologic assessment of organic contaminants in surface water using passive samplers

Passive sampling methodologies were used to conduct a chemical and toxicologic assessment of organic contaminants in the surface waters of three geographically distinct agricultural watersheds. A selection of current-use agrochemicals and persistent organic pollutants, including polycyclic aromatic hydrocarbons, polychlorinated biphenyls, and organochlorine pesticides, were targeted using the polar organic chemical integrative sampler (POCIS) and the semipermeable membrane device passive samplers. In addition to the chemical analysis, the Microtox assay for acute toxicity and the yeast estrogen screen (YES) were conducted as potential assessment tools in combination with the passive samplers. During the spring of 2004, the passive samplers were deployed for 29 to 65 d at Leary Weber Ditch, IN; Morgan Creek, MD; and DR2 Drain, WA. Chemical analysis of the sampler extracts identified the agrochemicals predominantly used in those areas, including atrazine, simazine, acetochlor, and metolachlor. Other chemicals identified included deethylatrazine and deisopropylatrazine, trifluralin, fluoranthene, pyrene, cis- and trans-nonachlor, and pentachloroanisole. Screening using Microtox resulted in no acutely toxic samples. POCIS samples screened by the YES assay failed to elicit a positive estrogenic response. Copyright ?? 2008 by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America. All rights reserved.

Journal of Environmental Quality↗

Overview and comparison of lipid-containing semipermeable membrane devices and oysters (Crassostrea gigas) for assessing organic chemical exposure

We performed 20-d, flow-through exposures of lipid-containing semipermeable membrane devices (SPMDs) and Pacific oysters ( Crassostrea gigas ) to three concentrations (nominally 10, 100, and 250 ng/L) of a diverse mixture of polycyclic aromatic hydrocarbons (PAHs). Exposure water was seawater free of particulates larger than 0.1 μm. The results of these controlled laboratory studies demonstrated that SPMDs and oysters concentrate the same chemicals but that the relative amounts accumulated are different. For oysters, the 20-d mean (across treatments) concentration factors (CFs) of test compounds with log K ow ≤ 4.8 were much lower (4.0- to 20-fold lower) than those of the same compounds in SPMDs. In contrast, the 20-d CFs of PAHs with log K ow ≥ 5.6 in oysters from the low-level treatment were higher than the corresponding CFs for SPMDs. The CFs of these compounds in oysters from the low-level treatment ranged from approximately 3.0- to 13-fold higher than those in oysters from the high-level treatment. This physiologically mediated difference in oyster CFs appears to be linked to active feeding in the low-level treatment and to apparent toxicity-induced cessation of feeding (i.e., valve closure) in the high-level treatment. Because CFs for these compounds in oysters were not independent of exposure concentrations, it follows that tissue levels were not proportional to exposure concentration. However, both sampling approaches have advantages and disadvantages, and the appropriateness of their use depends on the goals of a given study.

Environmental Toxicology and Chemistry↗

Development of the permeability/performance reference compound approach for in situ calibration of semipermeable membrane devices

Permeability/performance reference compounds (PRCs) are analytically noninterfering organic compounds with moderate to high fugacity from semipermeable membrane devices (SPMDs) that are added to the lipid prior to membrane enclosure. Assuming that isotropic exchange kinetics (IEK) apply and that SPMD-water partition coefficients are known, measurement of PRC dissipation rate constants during SPMD field exposures and laboratory calibration studies permits the calculation of an exposure adjustment factor (EAF). In theory, PRC-derived EAF ratios reflect changes in SPMD sampling rates (relative to laboratory data) due to differences in exposure temperature, membrane biofouling, and flow velocity-turbulence at the membrane surface. Thus, the PRC approach should allow for more accurate estimates of target solute/vapor concentrations in an exposure medium. Under some exposure conditions, the impact of environmental variables on SPMD sampling rates may approach an order of magnitude. The results of this study suggest that most of the effects of temperature, facial velocity-turbulence, and biofouling on the uptake rates of analytes with a wide range of hydrophobicities can be deduced from PRCs with a much narrower range of hydrophobicities. Finally, our findings indicate that the use of PRCs permits prediction of in situ SPMD sampling rates within 2-fold of directly measured values.

Environmental Science & Technology↗

TES observations of the martian surface and atmosphere

The TES instrument is a Fourier transform Michelson interferometer operating with 10 or 5 cm -1 sampling int he thermal infared spectral region from 1700 to 200 cm -1 (~6 to 50 μm) where virtually all minerals have characteristic fundamental vibrational absorption bands (1, 2, 3, 4, 5, 6, 7, 8). The TES data used in this paper are among the 6x10 7 spectra collected during the early mapping phase of the MGS mission from southern hemisphere winter to early summer (aerocentric longitude, L s , 107° to 297°. The methodology for separating the surface and atmospheric components of the radiance from Mars, which allows detailed analysis and interpretation of surface mineralogy (9, 10), is described in previous papers (10, 11).

Book↗

Determination of uptake kinetics (sampling rates) by lipid-containing semipermeable membrane devices (SPMDs) for polycyclic aromatic hydrocarbons (PAHs) in water

The use of lipid-containing semipermeable membrane devices (SPMDs) is becoming commonplace, but very little sampling rate data are available for the estimation of ambient contaminant concentrations from analyte levels in exposed SPMDs. We determined the aqueous sampling rates (R(s)s; expressed as effective volumes of water extracted daily) of the standard (commercially available design) 1-g triolein SPMD for 15 of the priority pollutant (PP) polycyclic aromatic hydrocarbons (PAHs) at multiple temperatures and concentrations. Under the experimental conditions of this study, recovery- corrected R(s) values for PP PAHs ranged from ???1.0 to 8.0 L/d. These values would be expected to be influenced by significant changes (relative to this study) in water temperature, degree of biofouling, and current velocity- turbulence. Included in this paper is a discussion of the effects of temperature and octanol-water partition coefficient (K(ow)); the impacts of biofouling and hydrodynamics are reported separately. Overall, SPMDs responded proportionally to aqueous PAH concentrations; i.e., SPMD R(s) values and SPMD-water concentration factors were independent of aqueous concentrations. Temperature effects (10, 18, and 26 ??C) on Rs values appeared to be complex but were relatively small.The use of lipid-containing semipermeable membrane devices (SPMDs) is becoming commonplace, but very little sampling rate data are available for the estimation of ambient contaminant concentrations from analyte levels in exposed SPMDs. We determined the aqueous sampling rates (Rss; expressed as effective volumes of water extracted daily) of the standard (commercially available design) 1-g triolein SPMD for 15 of the priority pollutant (PP) polycyclic aromatic hydrocarbons (PAHs) at multiple temperatures and concentrations. Under the experimental conditions of this study, recovery-corrected Rs values for PP PAHs ranged from ???1.0 to 8.0 L/d. These values would be expected to be influenced by significant changes (relative to this study) in water temperature, degree of biofouling, and current velocity-turbulence. Included in this paper is a discussion of the effects of temperature and octanol-water partition coefficient (KOW); the impacts of biofouling and hydrodynamics are reported separately. Overall, SPMDs responded proportionally to aqueous PAH concentrations; i.e., SPMD RS values and SPMD-water concentration factors were independent of aqueous concentrations. Temperature effects (10, 18, and 26??C) on RS values appeared to be complex but were relatively small.

Environmental Science & Technology↗