Search USGSSearch

Geology topics

Paul M. Gates

Publications and source records attributed to Paul M. Gates.

7 recordsLinked to original sources

Use of field-applied quality control samples to monitor performance of a Goulden large-sample extractor/GC-MS method for pesticides in water

Since 1985, the Goulden large-sample extractor (GLSE) has been used to isolate a broad array of trace-organic contaminants from large volumes of water. In this study, field-applied quality control measures, including matrix and surrogate spikes and blanks, were used to monitor method performance from GLSE extraction through GC-MS analysis. The method was applied to the determination of multiple classes of pesticides isolated from 4- to 112-L filtered surface-water samples. Average recoveries of six surrogate compounds ranged from 84 ?? 18% for [2H10]diazinon to 15 ?? 13% for 4,4'-[2H8]DDT, the low recoveries for which were largely a result of unmonitored breakdown of this surrogate by the GC injection system. Field-matrix-spike samples were prepared by fortifying 10-L, 35-L, and 110-L filtered surface-water samples with 68 pesticides to amended concentrations of 11- to 50-ng/L each. Recoveries ranged from not detected to greater than 100%. Variability in pesticide recoveries from triplicate 10-L water samples collected at one site averaged 5.7% relative standard deviation and did not exceed 19%.Since 1985, the Goulden large-sample extractor (GLSE) has been used to isolate a broad array of trace-organic contaminants from large volumes of water. In this study, field-applied quality control measures, including matrix and surrogate spikes and blanks, were used to monitor method performance from GLSE extraction through GC-MS analysis. The method was applied to the determination of multiple classes of pesticides isolated from 4- to 112-L filtered surface-water samples. Average recoveries of six surrogate compounds ranged from 84 ?? 18% for [2H10]diazinon to 15 ?? 13% for 4,4???-[2H8]DDT, the low recoveries for which were largely a result of unmonitored breakdown of this surrogate by the GC injection system. Field-matrix-spike samples were prepared by fortifying 10-L, 35-L, and 110-L filtered surface-water samples with 68 pesticides to amended concentrations of 11- to 50-ng/L each. Recoveries ranged from not detected to greater than 100%. Variability in pesticide recoveries from triplicate 10-L water samples collected at one site averaged 5.7% relative standard deviation and did not exceed 19%.

International Journal of Environmental Analytical

Determination of dissolved-phase pesticides in surface water from the Yakima River basin, Washington, using the Goulden large-sample extractor and gas chromatography/mass spectrometer

Concentrations of pesticides in the dissolved phase of surface water samples from the Yakima River basin, WA, were determined using preconcentration in the Goulden large-sample extractor (GLSE) and gas chromatography/mass spectrometry (GC/MS) analysis. Sample volumes ranging from 10 to 120 L were processed with the GLSE, and the results from the large-sample analyses were compared to those derived from 1-L continuous liquid-liquid extractions Few of the 40 target pesticides were detected in 1-L samples, whereas large-sample preconcentration in the GLSE provided detectable levels for many of the target pesticides. The number of pesticides detected in GLSE processed samples was usually directly proportional to sample volume, although the measured concentrations of the pesticides were generally lower at the larger sample volumes for the same water source. The GLSE can be used to provide lower detection levels relative to conventional liquid-liquid extraction in GC/MS analysis of pesticides in samples of surface water.

Washington

Performance of the goulden large-sample extractor in multiclass pesticide isolation and preconcentration from stream water

The reliability of the Goulden large-sample extractor in preconcentrating pesticides from water was evaluated from the recoveries of 35 pesticides amended to filtered stream waters. Recoveries greater than 90% were observed for many of the pesticides in each major chemical class, but recoveries for some of the individual pesticides varied in seemingly unpredictable ways. Corrections cannot yet be factored into liquid-liquid extraction theory to account for matrix effects, which were apparent between the two stream waters tested. The Goulden large-sample extractor appears to be well suited for rapid chemical screening applications, with quantitative analysis requiring special quality control considerations. ?? 1991 American Chemical Society.

Journal of Agricultural and Food Chemistry

Routine determination of sulfonylurea, imidazolinone, and sulfonamide herbicides at nanogram-per-liter concentrations by solid-phase extraction and liquid chromatography/mass spectrometry

Sulfonylurea (SU), imidazolinone (IMI), and sulfonamide (SA) herbicides are new classes of low-application-rate herbicides increasingly used by farmers. Some of these herbicides affect both weed and crop species at low dosages and must be carefully used. Less is known about the effect of these compounds on non-crop plant species, but a concentration of 100 ng/l in water has been proposed as the threshold for possible plant toxicity for most of these herbicides. Hence, analytical methods must be capable of detecting SUs, IMIs, and SAs at concentrations less than 100 ng/l in ambient water samples. The authors developed a two-cartridge, solid-phase extraction method for isolating 12 SU, 3 IMI, and 1 SA herbicides by using high-performance liquid chromatography/electrospray ionization-mass spectrometry (HPLC/ESI-MS) to identify and quantify these herbicides to 10 ng/l. This method was used to analyze 196 surface- and ground-water samples collected from May to August 1998 throughout the Midwestern United States, and more than 100 quality-assurance and quality-control samples. During the 16 weeks of the study, the HPLC/ESI-MS maintained excellent calibration linearity across the calibration range from 5 to 500 ng/l, with correlation coefficients of 0.9975 or greater. Continuing calibration verification standards at 100-ng/l concentration were analyzed throughout the study, and the average measured concentrations for individual herbicides ranged from 93 to 100 ng/l. Recovery of herbicides from 27 reagent-water samples spiked at 50 and 100 ng/l ranged from 39 to 92%, and averaged 73%. The standard deviation of recoveries ranged from 14 to 26%, and averaged 20%. This variability reflects multiple instruments, operators, and the use of automated and manual sample preparation. Spiked environmental water samples had similar recoveries, although for some herbicides, the sample matrix enhanced recoveries by as much as 200% greater than the spiked concentration. This matrix enhancement was sample- and compound-dependent. Concentrations of herbicides in unspiked duplicate environmental samples were typically within 25% of each other. The results demonstrate the usefulness of HPLC/ESI-MS for determining low-application-rate herbicides at ambient concentrations.

Science of Total Environment

Matrix-enhanced degradation of p,p'-DDT during gas chromatographic analysis: A consideration

Analysis of p,p &lsquo;-DDT in environmental samples requires monitoring the GC-derived breakdown of this insecticide, which produces p,p &lsquo;-DDD and/or p,p &lsquo;-DDE, both also primary environmental degradation products. A performance evaluation standard (PES) containing p,p &lsquo;-DDT but not p,p &lsquo;-DDD or p,p &lsquo;-DDE can be injected at regular intervals throughout an analytical sequence to monitor GC degradation. Some U.S. EPA methods limit GC breakdown of DDT in the PES to &le;20%. GC/MS analysis of large-volume natural water samples fortified with deuterium- and 13 C-labeled p,p &lsquo;-DDT exhibited up to 65% DDT breakdown by the GC inlet. These matrix-enhanced GC degradation amounts substantially exceeded the <20% breakdown levels indicated by bracketing injections of the PES containing unlabeled and labeled DDT. Substantial matrix-enhanced GC degradation was not observed during analysis of a limited number of fractionated bed-sediment extracts containing labeled DDT. Use of isotopically labeled DDT seems to provide an effective tool for monitoring sample-specific DDT breakdown during GC/MS analysis. However, analyte co-elutions render impractical their use in GC/ECD analysis. The oc currence of matrix-enhanced GC degradation might have important implications on data quality and the resultant interpretations of the environmental degradation of DDT and other thermolabile contaminants.

Environmental Science & Technology

Determination of nitroaromatic explosives and their degradation products in unsaturated-zone water samples by high-performance liquid chromatography with photodiode-array, mass spectrometric, and tandem mass spectrometric detection

Mass spectrometry and tandem mass spectrometry, coupled by a thermospray interface to a high-performance liguid chromatography system and equipped with a photodiode array detector, were used to determine the presence of nitroaromatic explosives and their degradation products in USA unsaturated-zone water samples. Using this approach, the lower limits of quantitation for explosives determined by mass spectrometry in this study typically ranged from 10 to 100 ng/l.

TrAC - Trends in Analytical Chemistry

Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory-Determination of semivolatile organic compounds in bottom sediment by solvent extraction, gel permeation chromatographic fractionation, and capillary-column gas chromatography/mass spectrometry

A method for the determination of 79 semivolatile organic compounds (SOCs) and 4 surrogate compounds in soils and bottom sediment is described. The SOCs are extracted from bottom sediment by solvent extraction, followed by partial isolation using high-performance gel permeation chromatography (GPC). The SOCs then are qualitatively identified and quantitative concentrations determined by capillary-column gas chromatography/mass spectrometry (GC/MS). This method also is designed for an optional simultaneous isolation of polychlorinated biphenyls (PCBs) and organochlorine (OC) insecticides, including toxaphene. When OCs and PCBs are determined, an additional alumina- over-silica column chromatography step follows GPC cleanup, and quantitation is by dual capillary- column gas chromatography with electron-capture detection (GC/ECD). Bottom-sediment samples are centrifuged to remove excess water and extracted overnight with dichloromethane. The extract is concentrated, centrifuged, and then filtered through a 0.2-micrometer polytetrafluoro-ethylene syringe filter. Two aliquots of the sample extract then are quantitatively injected onto two polystyrene- divinylbenzene GPC columns connected in series. The SOCs are eluted with dichloromethane, a fraction containing the SOCs is collected, and some coextracted interferences, including elemental sulfur, are separated and discarded. The SOC-containing GPC fraction then is analyzed by GC/MS. When desired, a second aliquot from GPC is further processed for OCs and PCBs by combined alumina-over-silica column chromatography. The two fractions produced in this cleanup then are analyzed by GC/ECD. This report fully describes and is limited to the determination of SOCs by GC/MS.

Open-File Report