Search USGS⌕ Search

Geology topics

Paul M. Bradley

Publications and source records attributed to Paul M. Bradley.

151 records · Page 9Linked to original sources

Microbial degradation of chloroethenes in groundwater systems

The chloroethenes, tetrachloroethene (PCE) and trichloroethene (TCE) are among the most common contaminants detected in groundwater systems. As recently as 1980, the consensus was that chloroethene compounds were not significantly biodegradable in groundwater. Consequently, efforts to remediate chloroethene-contaminated groundwater were limited to largely unsuccessful pump-and-treat attempts. Subsequent investigation revealed that under reducing conditions, aquifer microorganisms can reductively dechlorinate PCE and TCE to the less chlorinated daughter products dichloroethene (DCE) and vinyl chloride (VC). Although recent laboratory studies conducted with halorespiring microorganisms suggest that complete reduction to ethene is possible, in the majority of groundwater systems reductive dechlorination apparently stops at DCE or VC. However, recent investigations conducted with aquifer and stream-bed sediments have demonstrated that microbial oxidation of these reduced daughter products can be significant under anaerobic redox conditions. The combination of reductive dechlorination of PCE and TCE under anaerobic conditions followed by anaerobic microbial oxidation of DCE and VC provides a possible microbial pathway for complete degradation of chloroethene contaminants in groundwater systems.

Hydrogeology Journal↗

Natural attenuation of chlorinated volatile organic compounds in ground water at Area 6, Naval Air Station Whidbey Island, Washington

Natural attenuation is a viable alternative to pump and treat for meeting remediation objectives in the vicinity of the southern contaminant plume. The combination of historically low contaminant concentrations in ground water, a landfill cap that limits source area contributions, favorable conditions for degradation of VC, and a relatively long downgradient distance to potential receptors are all favorable for natural attenuation as a remediation alternative. Natural attenuation could effectively meet all but one remediation goal that extraction wells PW- 2, PW-4, PW-6, PW-7, PW-8 and PW-9 are currently being employed to meet. The goal of preventing migration of all VC across the site boundary could not be met by natural attenuation. Some VC would migrate south of the Navy boundary, but the potential for subsequent VC mineralization downgradient of the base and the existing institutional controls would result in minimal additional risk from using natural attenuation. In the western contaminant plume natural attenuation is not currently a viable alternative to pump and treat for meeting remediation objectives. There is a possibility that rates for reductive dechlorination of TCE and TCA could increase substantially if the plume was allowed to migrate beneath the Oak Harbor landfill, but there are not enough data to be certain of such an increase. TCA and TCE concentrations at the leading edge of the western plume need to be reduced to at least 25 and 40 µg/L, respectively, to be protective of potential downgradient receptors. Source area TCA and TCE concentrations have decreased substantially over the past ten years, and the extraction wells PW-3 and PW-5 in particular are removing a significant mass of contaminants from ground water, so natural attenuation may be a viable alternative for the western plume in the future. There would be some possible side benefits of using natural attenuation as an alternative to pump and treat in the southern contaminant plume. The first would be that the resulting decrease in the amount of treated water that would need to be recharged in the swale north of the landfill would result in less off-base migration of contamination across the western site boundary. The second benefit would be a substantial reduction in the amount of dissolved iron and manganese being extracted from the shallow aquifer and run through the treatment system. Removing that source of operation and maintenance problems would result in more effective containment and removal of contamination in the western contaminant plume. The most critical data gap identified in this evaluation is the paucity of contaminant chemistry information downgradient of the Navy boundary in the vicinity of the southern contaminant plume. Without such data, the behavior of the plume and the protectiveness of natural attenuation to downgradient receptors cannot be verified, and field attenuation rates for VC cannot be determined directly. The existing long-term monitoring plan would need to be reviewed and revised if natural attenuation is selected as a remedy for the contamination in the southern plume. In particular, additional performance monitoring wells may be required downgradient of the property.

Washington↗

Methodology for applying monitored natural attenuation to petroleum hydrocarbon-contaminated ground-water systems with examples from South Carolina

Natural attenuation processes such as dispersion, advection, and biogradation serve to decrease concentrations of disssolved contaminants as they are transported in all ground-water systems. However, the efficiency of these natural attenuation processes and the degree to which they help attain remediation goals, varies considerably from site to site. This report provides a methodology for quantifying various natural attenuation mechanisms. This methodology incorporates information on (1) concentrations of contaminants in space and/or time; (2) ambient reduction/oxidation (redox) conditions; (3) rates and directions of ground-water flow; (4) rates of contaminant biodegradation; and (5) demographic considerations, such as the presence of nearby receptor exposure points or property boundaries. This document outlines the hydrologic, geochemical, and biologic data needed to assess the efficiency of natural attenuation, provides a screening tool for making preliminary assessments, and provides examples of how to determine when natural attenuation can be a useful component of site remediation at leaking underground storage tank sites. At a site in the Piedmont Physiographic Province (Laurens, South Carolina), hydrologic and water-chemistry data indicate that the natural attenuation capacity for benzene is approximately 5 percent per foot of flowpath. As a result, benzene concentrations would decrease from about 28,000 micrograms per liter in ground water at the source area to less than 5 micrograms per liter 200 feet downgradient and prior to discharging to a stream. Because of this rapid attenuation, contaminants do not presently impact the stream downgradient of the site. In contrast, at a site in the coastal Plain Physiographic Province (Charleston, South Carolina), hydrologic and water-chemistry data indicate that, even thought the site has a substantial natural attenuation capacity, it may not be sufficient to fully protect a nearby point of ground-water discharge. These two sites illustrate how the efficiency of natural attenuation processes acting on petroleum hydrocarbons can be systematically evaluated using hydrologic, geochemical, and microbiologic methods. These methods, in turn, can be used to assess the role that the natural attenuation of petroleum hydrocarbons can play in achieving overall site remediation.

South Carolina↗

Role for acetotrophic methanogens in methanogenic biodegradation of vinyl chloride

Under methanogenic conditions, stream-bed sediment microorganisms rapidly degraded [1,2-14C]vinyl chloride to 14CH4 and 14CO2. Amendment with 2-bromoethanesulfonic acid eliminated 14CH4 production and decreased 14CO2 recovery by an equal molar amount. Results obtained with [14C]ethene, [14C]acetate, or 14CO2 as substrates indicated that acetotrophic methanogens were responsible for the production of 14CH4 during biodegradation of [1,2-14C]VC.Under methanogenic conditions, stream-bed sediment microorganisms rapidly degraded [1,2-14C]vinyl chloride to 14CH4 and 14CO2. Amendment with 2-bromoethanesulfonic acid eliminated 14CH4 production and decreased 14CO2 recovery by an equal molar amount. Results obtained with [14C]-ethene, [14C]acetate, or 14CO2 as substrates indicated that acetotrophic methanogens were responsible for the production of 14CH4, during biodegradation of [1,2-14C]VC.

Environmental Science & Technology↗

Anaerobic oxidation of [1,2-14C]dichloroethene under Mn(IV)-reducing conditions

Anaerobic oxidation of [1,2- 14 C]dichloroethene to 14 CO 2 under Mn(IV)-reducing conditions was demonstrated. The results indicate that oxidative degradation of partially chlorinated solvents like dichloroethene can be significant even under anoxic conditions and demonstrate the potential importance of Mn(IV) reduction for remediation of chlorinated groundwater contaminants.

Applied and Environmental Microbiology↗

Comparison of Eh and H2 measurements for delineating redox processes in a contaminated aquifer

Measurements of oxidation-reduction potential ( E h ) and concentrations of dissolved hydrogen (H 2 ) were made in a shallow groundwater system contaminated with solvents and jet fuel to delineate the zonation of redox processes. E h measurements ranged from +69 to -158 mV in a cross section of the contaminated plume and accurately delineated oxic from anoxic groundwater. Plotting measured E h and pH values on an equilibrium stability diagram indicated that Fe(III) reduction was the predominant redox process in the anoxic zone and did not indicate the presence of methanogenesis and sulfate reduction. In contrast, measurements of H 2 concentrations indicated that methanogenesis predominated in heavily contaminated sediments near the water table surface (H 2 ∼ 7.0 nM) and that the methanogenic zone was surrounded by distinct sulfate-reducing (H 2 ∼ 1-4 nM) and Fe(III)-reducing (H 2 ∼ 0.1-0.8 nM) zones. The presence of methanogenesis, sulfate reduction, and Fe(III) reduction was confirmed by the distribution of dissolved oxygen, sulfate, Fe(II), and methane in groundwater. These results show that H 2 concentrations were more useful for identifying anoxic redox processes than E h measurements in this groundwater system. However, H 2 -based redox zone delineations are more reliable when H 2 concentrations are interpreted in the context of electron-acceptor (oxygen, nitrate, sulfate) availability and the presence of final products [Fe(II), sulfide, methane] of microbial metabolism.

Environmental Science & Technology↗