Toward a near-lossless image compression strategy for the NASA/USGS Landsat Next mission

As orbiting Earth imaging platforms carry more complex and capable instruments, efficient methods are needed to reduce the time and cost associated with storing and downlinking greater volumes of image data. The upcoming NASA/USGS Landsat Next mission, with an increase in spatial and spectral resolution over previous Landsat missions, is no exception. Landsat Next will produce nearly six times the amount of image data per day over either of the current Landsat 8 or Landsat 9 observatories. Near-lossless compression, where the image after compression is not identical to the original image, allows for the efficient storage and transmission of all image data while meeting the mission’s global coverage, temporal revisit frequency, and science measurement and performance requirements. Although the Landsat user community is understandably cautious about lossy compression, it is possible to constrain the maximum loss, or error, introduced during compression, ensuring that any added error remains within the intrinsic noise level of the instrument. The Consultative Committee for Space Data Systems image compression standard, CCSDS 123.0-B-2, was chosen for the Landsat Next mission because it is an internationally supported standard suited for integration with space hardware, and it allows control over the magnitude and distribution of compression error. Using several proxy datasets as a surrogate for Landsat Next image data, an investigation was performed to determine a preliminary set of parameter values that would keep the added compression error within acceptable limits. The results of these studies demonstrate that near-lossless image compression can be utilized by the Landsat Next instruments to store and downlink all science data without compromising image quality or mission requirements.

Remote Sensing of Environment

Landsat 9 mission update and status

Landsat 9 is currently undergoing testing at the integrated observatory level in preparation for launch from Vandenberg Air Force Base in 2021. Landsat 9 will replace Landsat 7 in orbit, 8 days out of phase with Landsat 8. Landsat 9 is largely a copy of Landsat 8 in terms of instrumentation, with an Operational Land Imager (OLI), model #2 and a Thermal Infrared Sensor (TIRS), model #2. The TIRS-2 is more significantly changed from TIRS with increased redundancy, as well as changes to the telescope baffling to improve stray light control and a revised scene select mirror encoder mechanism. Data quality of the Landsat 9 instruments is comparable to, or better than the Landsat 8 ones, with an increase to 14 bits of data transmitted and more detailed pre-launch characterization for OLI-2, and with more detailed characterization of the TIRS-2 pre-launch, in addition to the improved stray light control. The performance of the two instruments is summarized and compared to that of the Landsat 8 instruments.

Conference Paper

Landsat-8 on-orbit and Landsat-9 pre-launch sensor radiometric characterization

Landsat-8 has been operating on-orbit for 5+ years. Its two sensors, the Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS), are continuing to produce high quality data. The OLI has been radiometrically stable at the better than 0.3% level on a band average basis for all but the shortest wavelength (443 nm) band, which has degraded about 1.3% since launch. All on-board calibration devices continue to perform well and consistently. No gaps in across track coverage exist as 100% operability of the detectors is maintained. The variability over time of detector responsivity within a band relative to the average is better than 0.05% (1 sigma), though there are occasional detectors that jump up to 1.5% in response in the Short-Wave InfraRed (SWIR) bands. Signal-to-Noise performance continues at 2-3x better than requirements, with a small degradation in the 443 nm band commensurate with the loss in sensitivity. Pre-launch error analysis, combined with the stability of the OLI indicates that the absolute reflectance calibration uncertainty is better than 3%; comparisons to ground measurements and comparisons to other sensors are consistent with this. The Landsat-8 TIRS is similarly radiometrically stable, showing changes of at most 0.3% over the mission. The uncertainty in the absolute calibration as well as the detector to detector variability are largely driven by the stray light response of TIRS. The current processing corrects most of the stray light effects, resulting in absolute uncertainties of ~1% and reduced striping. Efforts continue to further reduce the striping. Noise equivalent delta temperature is about 50 mK at typical temperatures and 100% detector operability is maintained. Landsat-9 is currently under development with a launch no earlier than December 2020. The nearly identical OLI-2 and upgraded TIRS-2 sensors have completed integration and are in the process of instrument level performance characterization including spectral, spatial, radiometric and geometric testing. Component and assembly level measurements of the OLI-2, which include spectral response, radiometric response and stray light indicate comparable performance to OLI. The first functional tests occurred in July 2018 and spatial performance testing in vacuum is scheduled for August 2018. Similarly, for TIRS-2, partially integrated instrument level testing indicated spectral and spatial responses comparable to TIRS, with stray light reduced by approximately an order of magnitude from TIRS.

Conference Paper

Landsat-8 TIRS thermal radiometric calibration status

The Thermal Infrared Sensor (TIRS) instrument is the thermal-band imager on the Landsat-8 platform. The initial onorbit calibration estimates of the two TIRS spectral bands indicated large average radiometric calibration errors, -0.29 and -0.51 W/m 2 sr μm or -2.1K and -4.4K at 300K in Bands 10 and 11, respectively, as well as high variability in the errors, 0.87K and 1.67K (1-σ), respectively. The average error was corrected in operational processing in January 2014, though, this adjustment did not improve the variability. The source of the variability was determined to be stray light from far outside the field of view of the telescope. An algorithm for modeling the stray light effect was developed and implemented in the Landsat-8 processing system in February 2017. The new process has improved the overall calibration of the two TIRS bands, reducing the residual variability in the calibration from 0.87K to 0.51K at 300K for Band 10 and from 1.67K to 0.84K at 300K for Band 11. There are residual average lifetime bias errors in each band: 0.04 W/m 2 sr μm (0.30K) and -0.04 W/m 2 sr μm (-0.29K), for Bands 10 and 11, respectively.

Conference Paper

Dark and background response stability for the Landsat 8 Thermal Infrared Sensor

The Thermal Infrared Sensor (TIRS) is a pushbroom sensor that will be a part of the Landsat Data Continuity Mission (LDCM), which is a joint mission between NASA and the USGS. The TIRS instrument will continue to collect the thermal infrared data that are currently being collected by the Thematic Mapper and the Enhanced Thematic Mapper Plus on Landsats 5 and 7, respectively. One of the key requirements of the new sensor is that the dark and background response be stable to ensure proper data continuity from the legacy Landsat instruments. Pre launch testing of the instrument has recently been completed at the NASA Goddard Space Flight Center (GSFC), which included calibration collects that mimic those that will be performed on orbit. These collects include images of a cold plate meant to simulate the deep space calibration source as viewed by the instrument in flight. The data from these collects give insight into the stability of the instrument’s dark and background response, as well as factors that may cause these responses to vary. This paper quantifies the measured background and dark response of TIRS as well as its stability.

Conference Paper