Search USGSSearch

Geology topics

M.L. Sorey

Publications and source records attributed to M.L. Sorey.

32 records · Page 2Linked to original sources

Hydrologic and geochemical monitoring in Long Valley Caldera, Mono County, California, 1985

Hydrologic and geochemical monitoring, to detect changes caused by magmatic and tectonic processes in the Long Valley caldera has continued through 1985. The monitoring included the collection of the following types of data: chemical and isotopic composition of water and gases from springs, wells, and steam vents; temperatures in wells, springs, and steam vents; flow rates of springs and streams; water levels in wells; and barometric pressure and precipitation at several sites. In addition, reservoir temperatures for the geothermal system were estimated from computations based on chemical geothermometers applied to fluid samples from wells and springs. Estimates of thermal water discharged from springs were made on the basis of boron and chloride fluxes in surface waters for selected sites in the Casa Diablo area and along the Mammoth-Hot Creek drainage. These data are presented in tables and graphs. The Long Valley area was relatively quiescent throughout 1985 in terms of geodetic changes and seismic activity. As a consequence , the hydrologic system varied mainly in response to seasonal influences of temperature, atmospheric pressure, and precipitation. However, spring flows near Casa Diablo were influenced by pumping at the geothermal production well field nearby. (Author 's abstract)

Water-Resources Investigations Report

CONCEPTUAL MODELS FOR THE LASSEN HYDROTHERMAL SYSTEM.

The Lassen hydrothermal system, like a number of other systems in regions of moderate to great topographic relief, includes steam-heated features at higher elevations and high-chloride springs at lower elevations, connected to and fed by a single circulation system at depth. Two conceptual models for such systems are presented. They are similar in several ways: however, there are basic differences in terms of the nature and extent of vapor-dominated conditions beneath the steam-heated features. For some Lassen-like systems, these differences could have environmental and economic implications. Available data do not make it possible to establish a single preferred model for the Lassen system, and the actual system is complex enough that both models may apply to different parts of the system.

Bulletin. Geothermal Resources Council

Hydrologic and geochemical monitoring in Long Valley caldera, Mono County, California, 1982-1984

The Long Valley caldera is a potentially active volcanic area on the eastern side of the Sierra Nevada in east-central California. Hydrologic and geochemical monitoring of surface and subsurface features began in July 1982 to determine if changes were occurring in response to processes causing earthquakes and crustal deformation. Differences since 1982 in fluid chemistry of springs has been minor except at Casa Diablo, where rapid fluctuations in chemistry result from near surface boiling and mixing. Ratios of 3 He/ 4 He and 13 C/ 12 C in hot springs and fumaroles are consistent with a magnetic source for some of the carbon and helium discharged in thermal areas, and observed changes in 3 He/ 4 He between 1978 and 1984 suggest changes in the magmatic component. Significant fluctuations in hot spring discharge recorded at several sites since 1982 closely followed earthquake activity. Water levels in wells have been used as strain meters to detect rock deformation associated with magmatic and tectonic activity and to construct a water table contour map. Coseismic water level fluctuations of as much as 0.6 ft have been observed but no clear evidence of deformation caused by magmatic intrusions can be seen in the well records through 1984. Temperature profiles in wells, which can be used to delineate regionally continuous zones of lateral flow of hot water across parts of the caldera, have remained constant at all but two sites.

California

Monitoring the hydrothermal system in Long Valley caldera, California

An ongoing program to monitor the hydrothermal system in Long Valley for changes caused by volcanic or tectonic processes has produced considerable data on the water chemistry and discharge of springs and fluid temperatures and pressures in wells. Chemical and isotopic data collected under this program have greatly expanded the knowledge of chemical variability both in space and time. Although no chemical or isotopic changes in hot spring waters can be attributed directly to volcanic or tectonic processes, changes in hot spring chemistry that have been recorded probably relate to interactions between and variations in the quantity of liquid and gas discharged. Stable carbon isotope data are consistent with a carbon source either perform the mantle or from metamorphosed carbonate rocks. Continuous and periodic measurements of hot spring discharge at several sites show significant co seismic and a seismic changes since 1980.

California

Quantitative analysis of the hydrothermal system in Lassen Volcanic National Park and Lassen Known Geothermal Resource Area

The conceptual model of the Lassen system is termed a liquid-dominated hydrothermal system with a parasitic vapor-dominated zone. The essential feature of this model is that steam and steam-heated discharge at relatively high elevations in Lassen Volcanic National Park (LVNP) and liquid discharge with high chloride concentrations at relatively low elevations outside LVNP are both fed by an upflow of high-enthalpy two-phase fluid within the Park. Liquid flows laterally away from the upflow area towards the areas of high-chloride discharge, and steam rises through a vapor-dominated zone to feed the steam and steam-heated features. Numerical simulations show that several conditions are necessary for the development of this type of system, including (1) large-scale topographic relief, (2) an initial period of convective heating within an upflow zone followed by some change in hydrologic or geologic conditions that initiates drainage of liquid from portions of the upflow zone, and (3) low permeability barriers that inhibit the movement of cold water into the vapor zone. Simulations of thermal fluid withdrawal south of LVNP, carried out in order to determine the effects of such withdrawal on portions of the hydrothermal system within the Park, showed decreases in pressure and liquid saturation beneath the vapor zone which result in a temporary increase and subsequent decrease in the rate of upflow of steam.

California

Selected data for low-temperature (less than 90 degrees C) geothermal systems in the United States; reference data for U.S. Geological Survey Circular 892

Supporting data are presented for the 1982 low-temperature geothermal resource assessment of the United States. Data are presented for 2072 geothermal sites which are representative of 1168 low-temperature geothermal systems identified in 26 States. The low-temperature geothermal systems consist of 978 isolated hydrothermal-convection systems, 148 delineated-area hydrothermal-convection systems, and 42 delineated-area conduction-dominated systems. The basic data and estimates of reservoir conditions are presented for each geothermal system, and energy estimates are given for the accessible resource base, resource, and beneficial heat for each isolated system.

Open-File Report

Changes in the discharge characteristics of thermal springs and fumaroles in the Long Valley Caldera, California, resulting from earthquakes on May 25-27, 1980

Changes in flow rate and turbidity have been observed and measured in hot springs in the Long Valley caldera, California, following earthquakes with magnitudes up to 6.3 in May 1980. Increases in flow rate of some hot springs occurred within minutes of the earthquakes, followed by more gradual decreases in flow rate to pre-earthquake levels. Spring temperatures and chemistries also show no long-term variations following earthquakes. Transient changes in discharge characteristics of the hot springs appear to result from increases in the permeability of fault conduits transmitting the hot water to the surface. (USGS)

Open-File Report

The hydrothermal system in southern Grass Valley, Pershing County, Nevada

Southern Grass Valley is typical extensional basin in the Basin and Range province. Leach Hot Springs, in the southern part of the valley, represents the discharge end of an active hydrothermal flow system with an estimated deep aquifer temperature of 163-173C. This report discusses results of geologic, hydrologic, geophysical and geochemical investigations used in an attempt to construct an internally consistent model of the system. (USGS)

Open-File Report

The hydrothermal system of Long Valley Caldera, California

Long Valley caldera, an elliptical depression covering 450 km 2 on the eastern front of the Sierra Nevada in east-central California, contains a hot-water convection system with numerous hot springs and measured and estimated aquifer temperatures at depths of 180?C to 280?C. In this study we have synthesized the results of previous geologic, geophysical, geochemical, and hydrologic investigations of the Long Valley area to develop a generalized conceptual and mathematical model which describes the gross features of heat and fluid flow in the hydrothermal system. Cenozoic volcanism in the Long Valley region began about 3.2 m.y. (million years) ago and has continued intermittently until the present time. The major event that resulted in the formation of the Long Valley caldera took place about 0.7 m.y. ago with the eruption of 600 km 3 or more of Bishop Tuff of Pleistocene age, a rhyolitic ash flow, and subsequent collapse of the roof of the magma chamber along one or more steeply inclined ring fractures. Subsequent intracaldera volcanism and uplift of the west-central part of the caldera floor formed a subcircular resurgent dome about 10 km in diameter surrounded by a moat containing rhyolitic, rhyodacitic, and basaltic rocks ranging in age from 0.5 to 0.05 m.y. On the basis of gravity and seismic studies, we estimate an aver- age thickness of fill of 2.4 km above the precaldera granitic and metamorphic basement rocks. A continuous layer of densely welded Bishop Tuff overlies the basement rocks, with an average thickness of 1.4 km; the fill above the welded Bishop Tuff consists of intercalated volcanic flows and tuffs and fluvial and lacustrine deposits. Assuming the average grain density of the fill is between 2.45 and 2.65 g/cm 3 , we calculate the average bulk porosity of the total fill as from 0.11 to 0.21. Comparison of published values of porosity of the welded Bishop Tuff exposed southeast of the caldera with calculated values indicates average bulk porosity for the welded tuff (including fracture porosity) from 0.05 to 0.10. Because of its continuity and depth and the likelihood of significant fracture permeability in the more competent rocks such as the welded tuff, our model of the hydrothermal system assumes that the Bishop Tuff provides the principal hot-water reservoir. However, because very little direct information exists from drill holes below 300 m, this assumption must be considered tentative. Long Valley caldera is drained by the Owens River and several tributaries which flow into Lake Crowley in the southeast end of the caldera. Streamflow and springflow measurements for water years 1964-74 indicate a total inflow to Lake Crowley of about 10,900 L/s. In contrast, the total discharge of hot water from the hydrothermal reservoir is about 300 L/s. For modeling purposes, the ground-water system is considered as comprising a shallow subsystem in the fill above the densely welded Bishop Tuff containing relatively cold ground water, and a deep subsystem or hydrothermal reservoir in the welded tuff containing relatively hot ground water. Hydrologic, isotopic, and thermal data indicate that recharge to the hydrothermal reservoir occurs in the upper Owens River drainage basin along the western periphery of the caldera. Temperature profiles in a 2.11- km-deep test well drilled by private industry in the southeastern part of the caldera suggest that an additional flux of relatively cool ground water recharges the deep subsystem around the northeast rim. Flow in the shallow ground-water subsystem is neglected in the model except in recharge areas and along Hot Creek gorge, where approximately 80 percent of the hot-water discharge from the hydrothermal reservoir moves upward along faults toward springs in the gorge. Heat-flow data from the Long Valley region indicate that the resurgent dome overlies a residual magma chamber more circular in plan than the original magma chamber that supplied the Bishop Tuff

California

Use of finite-difference arrays of observation wells to estimate evapotranspiration from ground water in the Arkansas River Valley, Colorado

A method to determine evapotranspiration from ground water was tested at four sites in the flood plain of the Arkansas River in Colorado. Approximate ground-water budgets were obtained by analyzing water-level data from observation wells installed in five-point arrays. The analyses were based on finite difference approximations of the differential equation describing ground-water flow. Data from the sites were divided into two groups by season. It was assumed that water levels during the dormant season were unaffected by evapotranspiration of ground water or by recharge, collectively termed 'accretion.' Regression analyses of these data were made to provide an equation for separating the effects of changes in aquifer storage and of aquifer heterogeneity from those due to accretion during the growing season. The data collected during the growing season were thus analyzed to determine accretion.

Water Supply Paper