Search USGSSearch

Geology topics

M.F. Schwartz

Publications and source records attributed to M.F. Schwartz.

3 recordsLinked to original sources

Acid neutralization within limestone sand reactors receiving coal mine drainage

Pulsed bed treatment of acid mine drainage (AMD) uses CO2 to accelerate limestone dissolution and intermittent fluidization to abrade and carry away metal hydrolysis products. Tests conducted with a prototype of 60 L/min capacity showed effective removal of H+ acidity over the range 196-584 mg/L (CaCO3) while concurrently generating surplus acid neutralization capacity. Effluent alkalinity (mg/L CaCO3) rose with increases in CO2 (DC, mg/L) according to the model Alkalinity = 31.22 + 2.97(DC)0.5, where DC was varied from 11-726 mg/L. Altering fluidization and contraction periods from 30 s/30 s to 10 s/50 s did not influence alkalinity but did increase energy dissipation and bed expansion ratios. Field trials with three AMD sources demonstrated the process is capable of raising AMD pH above that required for hydrolysis and precipitation of Fe3+ and Al3+ but not Fe2+ and Mn2+. Numerical modeling showed CO2 requirements are reduced as AMD acidity increases and when DC is recycled from system effluent. ?? 2005 Elsevier Ltd. All rights reserved.

Environmental Pollution

Feasibility of measuring dissolved carbon dioxide based on head space partial pressures

We describe an instrument prototype that measures dissolved carbon dioxide (DC) without need for standard wetted probe membranes or titration. DC is calculated using Henry's Law, water temperature, and the steady-state partial pressure of carbon dioxide that develops within the instrument's vertical gas-liquid contacting chamber. Gas-phase partial pressures were determined with either an infrared detector (ID) or by measuring voltage developed by a pH electrode immersed in an isolated sodium carbonate solution (SC) sparged with recirculated head space gas. Calculated DC concentrations were compared with those obtained by titration over a range of DC (2, 4, 8, 12, 16, 20, 24, and 28mg/l), total alkalinity (35, 120, and 250mg/l as CaCO3), total dissolved gas pressure (-178 to 120 mmHg), and dissolved oxygen concentrations (7, 14, and 18 mg/l). Statistically significant (P < 0.001) correlations were established between head space (ID) and titrimetrically determined DC concentrations (R2 = 0.987-0.999, N = 96). Millivolt and titrimetric values from the SC solution tests were also correlated (P < 0.001, R 2 = 0.997, N = 16). The absolute and relative error associated with the use of the ID and SC solution averaged 0.9mg/l DC and 7.0% and 0.6 mg/l DC and 9.6%, respectively. The precision of DC estimates established in a second test series was good; coefficients of variation (100(SD/mean)) for the head space (ID) and titration analyses were 0.99% and 1.7%. Precision of the SC solution method was 1.3%. In a third test series, a single ID was coupled with four replicate head space units so as to permit sequential monitoring (15 min intervals) of a common water source. Here, appropriate gas samples were secured using a series of solenoid valves (1.6 mm bore) activated by a time-based controller. This system configuration reduced the capital cost per sample site from US$ 2695 to 876. Absolute error averaged 2.9, 3.1, 3.7, and 2.7 mg/ l for replicates 1-4 (N = 36) during a 21-day test period (DC range, 36-40 mg/l). The ID meter was then modified so as to provide for DO as well as DC measurements across components of an intensive fish production system. ?? 2003 Elsevier B.V. All rights reserved.

Aquacultural Engineering

Hydraulic characteristics of a rectangular mixed-cell rearing unit

We describe a fish rearing unit modification that establishes mixed flow reactor (MFR) behavior in a rectangular vessel so as to eliminate metabolite concentration gradients, increase current velocities and improve solids scour at low water exchange rates. A standard raceway section 14.5 m long was modified to create six counter-rotating mixed cells, each 2.4 m wide by 2.4 m long. Cells receive water from vertical pipe sections extending to the tank floor and positioned in the corners of the cells. Vertical pipe sections were fabricated with jet ports that direct water into the cells tangentially to establish rotary circulation. Water exits each cell through a centrally located floor drain. Hydraulic characteristics of the tank are described based on an analysis of residence time distribution, current velocities and cell-to-cell water exchange rates. The latter was calculated based on a proposed hydraulics model and tracer concentrations established at a steady state. Vessel dispersion numbers measured with water exchange rates of 1.0 and 1.3 per hour, indicate tank performance approximates that of a MFR with the active tank volume representing 77.9–100% of total tank volume. Water velocities measured at 216 stations averaged 0.14, 0.12 and 0.12 m/s for the tank surface, mid-depth and near bottom regions. The benthic shear stress calculated given surface velocity was 0.04 N/m 2 . This was sufficient to scour and purge fecal solids produced by 2010 kg of lake trout that averaged 44.3 cm in total length. Cell interaction was significant with cell-to-cell exchange rates averaging 3.9 times the tank inflow rate. Energy requirements of the rearing unit were kept low (1.32 m water gauge pressure; 6.7 W/m 3 ) through use of a large number of low velocity jets.

Aquacultural Engineering