Geology topics
M. J. Fishman
Publications and source records attributed to M. J. Fishman.
Indirect spectrophotometric determination of traces of bromide in water
A rapid, accurate, and sensitive indirect spectrophotometric method for the determination of bromide in natural waters is based on the catalytic effect of bromide on the oxidation of iodine to iodate by potassium permanganate in sulfuric acid solution. The method is applicable to concentrations ranging from 1 to 100 μ g. of bromide per liter, but may be modified to extend the concentration range. Most ions commonly occurring in water do not interfere. The standard deviation is 2.9 at bromide concentrations of 100 μ g. per liter and less at lower concentrations. The determination of bromide in samples containing known added amounts gave values ranging from 99 to 105% of the concentration calculated to be present.
Validation of an automated fluorescein method for determining bromide in water
Surface, atmospheric precipitation and deionized water samples were spiked with ??g l-1 concentrations of bromide, and the solutions stored in polyethylene and polytetrafluoroethylene bottles. Bromide was determined periodically for 30 days. Automated fluorescein and ion chromatography methods were used to determine bromide in these prepared samples. Analysis of the data by the paired t-test indicates that the two methods are not significantly different at a probability of 95% for samples containing from 0.015 to 0.5 mg l-1 of bromide. The correlation coefficient for the same sets of paired data is 0.9987. Recovery data, except for the surface water samples to which 0.005 mg l-1 of bromide was added, range from 89 to 112%. There appears to be no loss of bromide from solution in either type of container.Surface, atmospheric precipitation and deionized water samples were spiked with mu g l** minus **1 concentrations of bromide, and the solutions stored in polyethylene and polytetrafluoroethylene bottles. Bromide was determined periodically for 30 days. Automated fluorescein and ion chromatography methods were used to determine bromide in these prepared samples. Analysis of the data by the paired t-test indicates that the two methods are not significantly different at a probability of 95% for samples containing from 0. 015 to 0. 5 mg l** minus **1 of bromide. The correlation coefficient for the same sets of paired data is 0. 9987. Recovery data, except for the surface water samples to which 0. 005 mg l** minus **1 of bromide was added, range from 89 to 112%. Refs.
Pilot study for U.S. Geological Survey Standard Reference Water Samples for pesticides
The U.S. Geological Survey has been preparing and maintaining a library of standard reference water samples for inorganic constituents for 19 years. Recently, a pilot study was conducted to see if the reference-sample program could be expanded to include pesticides and other organic materials. Two samples containing organochlorine and organophosphorus insecticides, and chlorophenoxy acid herbicides were distributed to a number of laboratories in the United States. One of the samples also contained polychlorinated biphenyls. Interlaboratory data obtained from these round robin studies are presented with intralaboratory information on long-term stability.
A Supplement to methods for the determination of inorganic substances in water and fluvial sediments, TWRI, Book 5, Chapter A1
No abstract available.
The use of standard reference water samples by the U.S. Geological Survey
Explore the source record for details and available documents.
Methods for analysis of inorganic substances in water and fluvial sediments
Explore the source record for details and available documents.
Land use and land cover and associated maps for Santa Maria, California
No abstract available.
Catalytic determination of vanadium in water
A kinetic determination of V(V) as a catalyst was spectrophotometrically performed by using the indicator reaction of Gallamine blue (GB + ) and bromate at pH 2.0. The reaction was followed by measuring absorbance change for a fixed-time of 3 min at 537 nm. The variables such as reagent concentration, pH, buffer concentration, ionic strength and temperature were optimized to improve the selectivity and sensitivity. Under the optimized conditions, the determination of V(V) was performed in the range 1–100 μg L −1 with limits of detection and quantification of 0.31 and 0.94 μg L −1 . The developed kinetic method is sufficiently sensitive, selective and simple. It was successfully applied to the speciative determination of total V and inorganic dissolved vanadium species, V(V) and V(IV) in environmental water samples. The oxidizing property of permanganate is used to differentiate between V(IV) and V(V) species. The V(IV) content was found by subtracting the V(V) content from those of total V. The recovery is above 95% for V(V) spiked samples. Additionally, the accuracy was validated by analysis of a certified water sample, CRM TMDA-53.3, and the results were in good agreement with the certified value.