Search USGSSearch

Geology topics

Kevin A. Oberg

Publications and source records attributed to Kevin A. Oberg.

16 recordsLinked to original sources

Validation of streamflow measurements made with M9 and RiverRay acoustic Doppler current profilers

The U.S. Geological Survey (USGS) Office of Surface Water (OSW) previously validated the use of Teledyne RD Instruments (TRDI) Rio Grande (in 2007), StreamPro (in 2006), and Broadband (in 1996) acoustic Doppler current profilers (ADCPs) for streamflow (discharge) measurements made by the USGS. Two new ADCPs, the SonTek M9 and the TRDI RiverRay, were first used in the USGS Water Mission Area programs in 2009. Since 2009, the OSW and USGS Water Science Centers (WSCs) have been conducting field measurements as part of their stream-gaging program using these ADCPs. The purpose of this paper is to document the results of USGS OSW analyses for validation of M9 and RiverRay ADCP streamflow measurements. The OSW required each participating WSC to make comparison measurements over the range of operating conditions in which the instruments were used until sufficient measurements were available. The performance of these ADCPs was evaluated for validation and to identify any present and potential problems. Statistical analyses of streamflow measurements indicate that measurements made with the SonTek M9 ADCP using firmware 2.00–3.00 or the TRDI RiverRay ADCP using firmware 44.12–44.15 are unbiased, and therefore, can continue to be used to make streamflow measurements in the USGS stream-gaging program. However, for the M9 ADCP, there are some important issues to be considered in making future measurements. Possible future work may include additional validation of streamflow measurements made with these instruments from other locations in the United States and measurement validation using updated firmware and software.

Journal of Hydraulic Engineering

Measuring discharge with acoustic Doppler current profilers from a moving boat

The use of acoustic Doppler current profilers (ADCPs) from a moving boat is now a commonly used method for measuring streamflow. The technology and methods for making ADCP-based discharge measurements are different from the technology and methods used to make traditional discharge measurements with mechanical meters. Although the ADCP is a valuable tool for measuring streamflow, it is only accurate when used with appropriate techniques. This report presents guidance on the use of ADCPs for measuring streamflow; this guidance is based on the experience of U.S. Geological Survey employees and published reports, papers, and memorandums of the U.S. Geological Survey. The guidance is presented in a logical progression, from predeployment planning, to field data collection, and finally to post processing of the collected data. Acoustic Doppler technology and the instruments currently (2013) available also are discussed to highlight the advantages and limitations of the technology. More in-depth, technical explanations of how an ADCP measures streamflow and what to do when measuring in moving-bed conditions are presented in the appendixes. ADCP users need to know the proper procedures for measuring discharge from a moving boat and why those procedures are required, so that when the user encounters unusual field conditions, the procedures can be adapted without sacrificing the accuracy of the streamflow-measurement data.

Techniques and Methods

Computing discharge using the index velocity method

Application of the index velocity method for computing continuous records of discharge has become increasingly common, especially since the introduction of low-cost acoustic Doppler velocity meters (ADVMs) in 1997. Presently (2011), the index velocity method is being used to compute discharge records for approximately 470 gaging stations operated and maintained by the U.S. Geological Survey. The purpose of this report is to document and describe techniques for computing discharge records using the index velocity method. Computing discharge using the index velocity method differs from the traditional stage-discharge method by separating velocity and area into two ratings—the index velocity rating and the stage-area rating. The outputs from each of these ratings, mean channel velocity (V) and cross-sectional area (A), are then multiplied together to compute a discharge. For the index velocity method, V is a function of such parameters as streamwise velocity, stage, cross-stream velocity, and velocity head, and A is a function of stage and cross-section shape. The index velocity method can be used at locations where stage-discharge methods are used, but it is especially appropriate when more than one specific discharge can be measured for a specific stage. After the ADVM is selected, installed, and configured, the stage-area rating and the index velocity rating must be developed. A standard cross section is identified and surveyed in order to develop the stage-area rating. The standard cross section should be surveyed every year for the first 3 years of operation and thereafter at a lesser frequency, depending on the susceptibility of the cross section to change. Periodic measurements of discharge are used to calibrate and validate the index rating for the range of conditions experienced at the gaging station. Data from discharge measurements, ADVMs, and stage sensors are compiled for index-rating analysis. Index ratings are developed by means of regression techniques in which the mean cross-sectional velocity for the standard section is related to the measured index velocity. Most ratings are simple-linear regressions, but more complex ratings may be necessary in some cases. Once the rating is established, validation measurements should be made periodically. Over time, validation measurements may provide additional definition to the rating or result in the creation of a new rating. The computation of discharge is the last step in the index velocity method, and in some ways it is the most straight-forward step. This step differs little from the steps used to compute discharge records for stage-discharge gaging stations. The ratings are entered into database software used for records computation, and continuous records of discharge are computed.

Techniques and Methods

Acoustic Doppler current profiler applications used in rivers and estuaries by the U.S. Geological Survey

The U.S. Geological Survey (USGS) has collected streamflow information for the Nation's streams since 1889. Streamflow information is used to predict floods, manage and allocate water resources, design engineering structures, compute water-quality loads, and operate water-control structures. The current (2007) size of the USGS streamgaging network is over 7,400 streamgages nationwide. The USGS has progressively improved the streamgaging program by incorporating new technologies and techniques that streamline data collection while increasing the quality of the streamflow data that are collected. The single greatest change in streamflow measurement technology during the last 100 years has been the development and application of high frequency acoustic instruments for measuring streamflow. One such instrument, the acoustic Doppler current profiler (ADCP), is rapidly replacing traditional mechanical current meters for streamflow measurement (Muste and others, 2007). For more information on how an ADCP works see Simpson (2001) or visit http://hydroacoustics.usgs.gov/. The USGS has used ADCPs attached to manned or tethered boats since the mid-1990s to measure streamflow in a wide variety of conditions (fig. 1). Recent analyses have shown that ADCP streamflow measurements can be made with similar or greater accuracy, efficiency, and resolution than measurements made using conventional current-meter methods (Oberg and Mueller, 2007). ADCPs also have the ability to measure streamflow in streams where traditional current-meter measurements previously were very difficult or costly to obtain, such as streams affected by backwater or tides. In addition to streamflow measurements, the USGS also uses ADCPs for other hydrologic measurements and applications, such as computing continuous records of streamflow for tidally or backwater affected streams, measuring velocity fields with high spatial and temporal resolution, and estimating suspended-sediment concentrations. An overview of these applications is provided in the fact sheet.

Fact Sheet

Laboratory evaluation of an OTT acoustic digital current meter and a SonTek Laboratory acoustic Doppler velocimeter

Recently, an acoustic current meter known as the OTT * acoustic digital current meter (ADC) was introduced as an alternative instrument for stream gaging measurements. The Bureau of Reclamation and the U.S. Geological Survey collaborated on a side- by-side evaluation of the ADC and a SonTek/YSI acoustic Doppler velocimeter (ADV). Measurements were carried out in a laboratory flume to evaluate the performance characteristics of the ADC under a range of flow and boundary conditions. The flume contained a physical model of a mountain river with a diversion dam and variety of bed materials ranging from smooth mortar to a cobble bed. The instruments were installed on a trolley system that allowed them to be easily moved within the flume while maintaining a consistent probe orientation. More than 50 comparison measurements were made in an effort to verify the manufacturer’s performance specifications and to evaluate potential boundary disturbance for near-bed and vertical boundary measurements. Data and results from this evaluation are presented and discussed.

Conference Paper

Temporal characteristics of coherent flow structures generated over alluvial sand dunes, Mississippi River, revealed by acoustic doppler current profiling and multibeam echo sounding

This paper investigates the flow in the lee of a large sand dune located at the confluence of the Mississippi and Missouri Rivers, USA. Stationary profiles collected from an anchored boat using an acoustic Doppler current profiler (ADCP) were georeferenced with data from a real-time kinematic differential global positioning system. A multibeam echo sounder was used to map the bathymetry of the confluence and provided a morphological context for the ADCP measurements. The flow in the lee of a low-angle dune shows good correspondence with current conceptual models of flow over dunes. As expected, quadrant 2 events (upwellings of low-momentum fluid) are associated with high backscatter intensity. Turbulent events generated in the lower lee of a dune near the bed are associated with periods of vortex shedding and wake flapping. Remnant coherent structures that advect over the lower lee of the dune in the upper portion of the water column, have mostly dissipated and contribute little to turbulence intensities. The turbulent events that occupy most of the water column in the upper lee of the dune are associated with periods of wake flapping.

Missouri

Velocity mapping in the Lower Congo River: A first look at the unique bathymetry and hydrodynamics of Bulu Reach

The lower Congo River is one of the deepest, most powerful, and most biologically diverse stretches of river on Earth. The river’s 270 m decent from Malebo Pool though the gorges of the Crystal Mountains to the Atlantic Ocean (498 km downstream) is riddled with rapids, cataracts, and deep pools. Much of the lower Congo is a mystery from a hydraulics perspective. However, this stretch of the river is a hotbed for biologists who are documenting evolution in action within the diverse, but isolated, fish populations. Biologists theorize that isolation of fish populations within the lower Congo is due to barriers presented by flow structure and bathymetry. To investigate this theory, scientists from the U.S. Geological Survey and American Museum of Natural History teamed up with an expedition crew from National Geographic in 2008 to map flow velocity and bathymetry within target reaches in the lower Congo River using acoustic Doppler current profilers (ADCPs) and echo sounders. Simultaneous biological and water quality sampling was also completed. This paper presents some preliminary results from this expedition, specifically with regard to the velocity structure andbathymetry. Results show that the flow in the bedrock controlled Bulu reach of the lower Congo is highly energetic. Turbulent and secondary flow structures can span the full depth of flow (up to 165 m), while coherent bank-to-bank cross-channel flow structures are absent. Regions of flow separation near the banks are isolated from one another and from the opposite bank by high shear, high velocity zones with depth-averaged flow velocities that can exceed 4 m/s.

Lower Congo River

Density currents in the Chicago River: Characterization, effects on water quality, and potential sources

Bidirectional flows in a river system can occur under stratified flow conditions and in addition to creating significant errors in discharge estimates, the upstream propagating currents are capable of transporting contaminants and affecting water quality. Detailed field observations of bidirectional flows were made in the Chicago River in Chicago, Illinois in the winter of 2005-06. Using multiple acoustic Doppler current profilers simultaneously with a water-quality profiler, the formation of upstream propagating density currents within the Chicago River both as an underflow and an overflow was observed on three occasions. Density differences driving the flow primarily arise from salinity differences between intersecting branches of the Chicago River, whereas water temperature is secondary in the creation of these currents. Deicing salts appear to be the primary source of salinity in the North Branch of the Chicago River, entering the waterway through direct runoff and effluent from a wastewater-treatment plant in a large metropolitan area primarily served by combined sewers. Water-quality assessments of the Chicago River may underestimate (or overestimate) the impairment of the river because standard water-quality monitoring practices do not account for density-driven underflows (or overflows). Chloride concentrations near the riverbed can significantly exceed concentrations at the river surface during underflows indicating that full-depth parameter profiles are necessary for accurate water-quality assessments in urban environments where application of deicing salt is common.

Illinois

Measurement of velocities with an acoustic velocity meter, one side-looking and two upward-looking acoustic Doppler current profilers in the Chicago Sanitary and Ship Canal, Romeoville, Illinois

In 1998, a prototype 300 kHz, side-looking Acoustic Doppler Current Profiler (ADCP) was deployed in the Chicago Sanitary and Ship Canal (CSSC) at Romeoville, Illinois. Additionally, two upward-looking ADCP's were deployed in the same acoustic path as the side-looking ADCP and in the reach defined by the upstream and downstream acoustic velocity meter (AVM) paths. All three ADCP's were synchronized to the AVM clock at the gaging station so that data were sampled simultaneously. The three ADCP's were deployed for six weeks measuring flow velocities from 0.0 to 2.5 ft/s. Velocities measured by each ADCP were compared to AVM path velocities and to velocities measured by the other ADCP's.

Proceedings of the IEEE Working Conference on Curr

Geomorphic changes on the Mississippi River flood plain at Miller City, Illinois, as a result of the flood of 1993

During the 1993 floods on the upper Mississippi and Missouri rivers, the most dramatic changes to floodplains occurred at levee-break complexes where large discharges were concentrated through narrow breaks in levees. Scour and deposition associated with levee breaks adversely affected large areas of formerly productive bottomland. This case study of the levee-break complex at Miller City, Illinois, documents the geomorphic effects of a typical levee-break complex.

Illinois

Comparison, analysis, and estimation of discharge data from two acoustic velocity meters on the Chicago Sanitary and Ship Canal at Romeoville, Illinois

The acoustic velocity meter (AVM) on the Chicago Sanitary and Ship Canal (the Canal) at Romeoville, Ill., provides vital information for the accounting of the diversion of water from Lake Michigan. A detailed analysis of the discharge record on the Canal at Romeoville was done by the U.S. Geological Survey to establish the most accurate estimates of discharge for water years 1986-91. The analysis involved (1) checking the consistency of the discharges estimated by two different AVM's installed at Romeoville for consecutive time periods by statistical and regression analyses, (2) adjusting the discharge record to account for corrections to the width and depth of the Canal determined by field measurements, and (3) development of equations for estimating discharge on days when the AVM was inoperative using discharge estimates made by the Metropolitan Water Reclamation District of Greater Chicago at the lock, powerhouse, and controlling works at Lockport, Ill. No signi- ficant difference in the discharge estimates made by the two AVM's could be documented. The estimation equations combined regression analysis with physical principles of the outlet-works operation. The estimation equations simulated the verification period of October 1, 1991, to May 31, 1992, within 0.22, 5.15, and 0.66 percent for the mean, standard deviation, and skewness coefficient, respectively. Discharges were recalculated for the corrected width and depth, estimated for the periods of AVM inoperation, and entered into the discharge record for the station.

Water-Resources Investigations Report

GEOGRAPHIC ESTIMATION OF RUNOFF-MODEL PARAMETERS.

The U. S. Geological Survey is developing techniques to estimate and evaluate unit-hydrograph and loss-rate parameter values for rainfall-runoff models using Geographic Information System (GIS) procedures. The data base includes basin, soil, and climatological characteristics that will be stored in a GIS, and unit-hydrograph and loss-rate parameters obtained from calibration of a commonly used flood-hydrograph rainfall-runoff model for 616 storms in 98 gaged drainage basins. Development of unit-hydrograph and loss-rate parameter-estimation techniques includes statistical methods (exploratory data analysis, regression analysis, and categorical data analysis) to relate the model parameters to hydrologic characteristics. The estimation techniques are evaluated by use of error analysis of simulated hydrograph characteristics (peak discharge, flood volume, and time to peak discharge). The hydrographs will be simulated with parameters estimated by the techniques for (1) 102 storms occurring at 36 gaged basins; and (2) a large storm system (one which produced floods with a 50-to 100-year recurrence interval).

Conference Paper

Time of concentration and storage coefficient values for Illinois streams

Values of time of concentration and storage coefficient, two unit hydrograph parameters, are presented for 194 and 120 basins in Illinois. Tabulated values consist of those computed by previous investigators as well as those computed for 98 basins as part of this investigation. These additional values were computed by calibration of the U.S. Army Corps of Engineers Flood Hydrograph Package (HEC-1). The significance of differences in method used by each investigator to compute these unit hydrography parameters was evaluated by statistical comparison of four sets of time of concentration values and three sets of storage coefficient values. Because no difference due to method was identified, it is concluded that all of the values tabulated in this report can be used in any application for which time of concentration and storage coefficient are required.

Illinois

A technique for estimating time of concentration and storage coefficient values for Illinois streams

Values of the unit hydrograph parameters time of concentration ( TC ) and storage coefficient ( R ) can be estimated for streams in Illinois by a two-step technique developed from data for 98 gaged basins in the State. The sum of TC and R is related to stream length ( L ) and main channel slope ( S ) by the relation ( TC + R ) e = 35.2 L 0.39 S -0.78 . The variable R /( TC + R ) is not significantly correlated with drainage area, slope, or length, but does exhibit a regional trend. Regional values of R /( TC + R ) are used with the computed values of ( TC + R ) e to solve for estimated values of time of concentration ( TC e ) and storage coefficient ( R e ). The use of the variable R /( TC + R ) is thought to account for variations in unit hydrograph parameters caused by physiographic variables such as basin topography, flood-plain development, and basin storage characteristics.

Illinois