Search USGSSearch

Geology topics

John D. Gordon

Publications and source records attributed to John D. Gordon.

10 recordsLinked to original sources

Regional regression equations for estimation of four hydraulic properties of streams at approximate bankfull conditions for different ecoregions in Texas

The U.S. Geological Survey, in cooperation with the U.S. Army Corps of Engineers, assessed statistical relations between hydraulic properties of streams at approximate bankfull conditions for different ecological regions (ecoregions) in Texas. Data from more than 103,000 records of measured discharge and ancillary hydraulic properties were assembled from summaries of discharge measurements for 424 U.S. Geological Survey streamgages in Texas. The data were subsequently subsetted at each streamgage for a streamgage-specific discharge interval centered on the estimated median annual peak discharge (0.5 annual exceedance probability) obtained from previously published regional regression equations in Texas in conjunction with the streamgage-specific sample median annual peak discharge for the period of record for each streamgage. Discharge measurements at gaged locations representing bankfull conditions (approximated from a discharge interval centered on the estimated median annual peak discharge at a given site) and associated watershed properties were subjected to rigorous statistical analysis. For most discharge measurements (where discharge is symbolically represented as Q ), the following hydraulic properties are available: cross-section area ( A ), water-surface top width ( B ), and reported mean velocity ( V ). Statewide summary statistics were computed by using these four hydraulic properties ( Q , A , B , and V ) and the following five watershed properties: (1) watershed area (contributing drainage area), (2) a multiple of main-channel slope (1,000 times main-channel slope), (3) mean annual precipitation, (4) drainage density, and (5) sinuosity ratio. From the initial set of 424 streamgages, summary statistics were computed for 372 selected streamgages in Texas and constitute the subsetted measurements dataset described in this report. Eight of the 10 ecoregions in Texas are represented in the statewide summary statistics. The resulting statistical relations, expressed as regression equations, can be used to estimate cross-section area, water-surface top width, discharge, and mean velocity of streams in different Texas ecoregions, at approximate bankfull conditions. In the regression equations, watershed properties were the independent variables for applicable watersheds, and predictions from the equations might be useful for estimating the four hydraulic properties at ungaged or unmonitored locations from selected characteristics measured at both the ungaged locations and gaged locations. Four regression equations to estimate the four hydraulic properties were identified as the preferred equations from this study. The four preferred equations use watershed area, mean annual precipitation, and aggregated ecoregion (treated as a categorical variable) to estimate the hydraulic properties, and justification is provided for this preference. For the four equations, the proportions of variance explained by the regression equations as measured by Nash-Sutcliffe efficiency are about 71 percent for cross-section area, 36 percent for top width, 76 percent for discharge, and 25 percent for mean velocity. Residual standard error (RSEs) of the regression equations are 0.252 log10 square feet for cross-section area, 0.319 log10 feet for top width, 0.247 log10 cubic feet per second for discharge, and 0.190 log10 feet per second for mean velocity, and the corresponding standard deviations of response are 0.465 log10 square feet, 0.397 log10 feet, 0.507 log10 cubic feet per second, and 0.220 log10 feet per second, respectively. The residual standard errors are less than the standard deviations as anticipated but show that the uncertainty reduction (percent change) for cross-section area is about −46 percent, about −20 percent for top width, about −51 percent for discharge, and about −14 percent for mean velocity.

Texas

Refining previous estimates of groundwater outflows from the Medina/Diversion Lake system, San Antonio area, Texas

Introduction In 2016, the U.S. Geological Survey (USGS), in cooperation with the San Antonio Water System, began a study to refine previously derived estimates of groundwater outflows from Medina and Diversion Lakes in south-central Texas near San Antonio. When full, Medina and Diversion Lakes (hereinafter referred to as the Medina/Diversion Lake system) (fig. 1) impound approximately 255,000 acre-feet and 2,555 acre-feet of water, respectively. Most recharge to the Edwards aquifer occurs as seepage from streams as they cross the outcrop (recharge zone) of the aquifer (Slattery and Miller, 2017). Groundwater outflows from the Medina/Diversion Lake system have also long been recognized as a potentially important additional source of recharge. Puente (1978) published methods for estimating monthly and annual estimates of the potential recharge to the Edwards aquifer from the Medina/Diversion Lake system. During October 1995–September 1996, the USGS conducted a study to better define short-term rates of recharge and to reduce the error and uncertainty associated with estimates of monthly recharge from the Medina/Diversion Lake system (Lambert and others, 2000). As a followup to that study, Slattery and Miller (2017) published estimates of groundwater outflows from detailed water budgets for the Medina/Diversion Lake system during 1955–1964, 1995–1996, and 2001–2002. The water budgets were compiled for selected periods during which time the water-budget components were inferred to be relatively stable and the influence of precipitation, stormwater runoff, and changes in storage were presumably minimal. Linear regression analysis techniques were used by Slattery and Miller (2017) to assess the relation between the stage in Medina Lake and groundwater outflows from the Medina/Diversion Lake system.

Texas

Surface water-quality and water-quantity data from selected urban runoff-monitoring sites at the Rocky Mountain Arsenal, Commerce City, Colorado, water years 1988-2004

The U.S. Geological Survey has monitored the quality and quantity of streamflow at the Rocky Mountain Arsenal (RMA) northeast of Denver, Colorado, since the early 1990s in cooperation with the U.S. Army. This report, prepared in cooperation with the U.S. Fish and Wildlife Service, documents existing surface-water-quality conditions on the RMA. All RMA water-quality data for the Irondale Gulch and First Creek Basins adjacent to and on the RMA were reviewed. Where applicable, water-quality data were compared to State standards established by the Colorado Department of Public Health and Environment. At both the Havana Interceptor below 56th Avenue gaging station and the Uvalda Interceptor below 56th Avenue gaging station, all of the dissolved-oxygen concentrations met the State standard requiring at least 5.0 milligrams per liter (mg/L) of dissolved oxygen for the protection of aquatic life. In contrast, the dissolved-oxygen concentrations at the Peoria Interceptor below 56th Avenue gage commonly were less than 5.0 mg/L. Excluding one suspect concentration of 1.6 mg/L, the dissolved-oxygen concentrations for the First Creek Basin ranged from 4.2 to 12.6 mg/L. Excluding the one suspect value, three dissolved-oxygen concentrations failed to meet the State standard of 5.0 mg/L at the First Creek below Buckley Road site. At the Peoria Interceptor below 56th Avenue site, all pH values were within the range specified by the State standard (6.50-8.99). Results of seven sampling events at the Havana Interceptor below 56th Avenue gaging station indicated a pH greater than or equal to 9 (pH values of 9 or greater exceed the upper limit of the standard). No sampling events indicated a pH less than 6.50. Results from one sampling event at the Uvalda Interceptor below 56th Avenue indicated pH values outside the range specified by the State standard. The concentrations obtained for chloride, magnesium, and sodium generally were below 200 mg/L at all three Irondale Gulch monitoring stations for the entire period of record, but there were a few sampling events at each of these sites where much higher concentrations for these analytes were obtained. The median concentrations for calcium, magnesium, and sodium generally were higher at the First Creek below Buckley Road site than in the three Irondale Gulch sites, while the 90th percentile and maximum concentrations for magnesium and sodium generally were higher at the three Irondale Gulch sites than at the First Creek below Buckley Road site. The urban runoff flowing onto the RMA had low concentrations and few, if any, detections for most organic contaminants. Part of the reason for low detections of organic contaminants may be in how the samples are collected. The existing surface-water sampling program was not designed specifically to target storm runoff and therefore does not characterize water quality for all hydrologic regimes, most notably storm runoff. As a result, the existing data may not adequately represent potential contaminant transport onto the RMA. In addition, during stormwater-runoff events, the sites examined for this report frequently are subject to sharp increases in discharge, and just as quickly the discharge rapidly recedes. These types of transient flow events make water-quality sampling difficult, and none of the sites have a safe place to sample the higher flows that occur in any given year. As a result, most of the surface-water-quality samples were collected after the flow had decreased substantially from the peak flow, which may have transported much of the chemical contaminant load through the system. Thus, little is known about the water quality during the critical initial stormwater-runoff period when contaminants are most likely to be mobilized and transported through the stormwater conveyances past the locations where gaging stations are located.

Colorado

External quality-assurance results for the national atmospheric deposition program/national trends network, 2000-2001

Five external quality-assurance programs were operated by the U.S. Geological Survey for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN) from 2000 through 2001 (study period): the intersite-comparison program, the blind-audit program, the field-audit program, the interlaboratory-comparison program, and the collocated-sampler program. Each program is designed to measure specific components of the total error inherent in NADP/NTN wet-deposition measurements. The intersite-comparison program assesses the variability and bias of pH and specific-conductance determinations made by NADP/NTN site operators with respect to accuracy goals. The accuracy goals are statistically based using the median of all of the measurements obtained for each of four intersite-comparison studies. The percentage of site operators responding on time that met the pH accuracy goals ranged from 84.2 to 90.5 percent. In these same four intersite-comparison studies, 88.9 to 99.0 percent of the site operators met the accuracy goals for specific conductance. The blind-audit program evaluates the effects of routine sample handling, processing, and shipping on the chemistry of weekly precipitation samples. The blind-audit data for the study period indicate that sample handling introduced a small amount of sulfate contamination and slight changes to hydrogen-ion content of the precipitation samples. The magnitudes of the paired differences are not environmentally significant to NADP/NTN data users. The field-audit program (also known as the 'field-blank program') was designed to measure the effects of field exposure, handling, and processing on the chemistry of NADP/NTN precipitation samples. The results indicate potential low-level contamination of NADP/NTN samples with calcium, ammonium, chloride, and nitrate. Less sodium contamination was detected by the field-audit data than in previous years. Statistical analysis of the paired differences shows that contaminant ions are entrained into the solutions from the field-exposed buckets, but the positive bias that results from the minor amount of contamination appears to affect the analytical results by less than 6 percent. An interlaboratory-comparison program is used to estimate the analytical variability and bias of participating laboratories, especially the NADP Central Analytical Laboratory (CAL). Statistical comparison of the analytical results of participating laboratories implies that analytical data from the various monitoring networks can be compared. Bias was identified in the CAL data for ammonium, chloride, nitrate, sulfate, hydrogen-ion, and specific-conductance measurements, but the absolute value of the bias was less than analytical minimum reporting limits for all constituents except ammonium and sulfate. Control charts show brief time periods when the CAL's analytical precision for sodium, ammonium, and chloride was not within the control limits. Data for the analysis of ultrapure deionized-water samples indicated that the laboratories are maintaining good control of laboratory contamination. Estimated analytical precision among the laboratories indicates that the magnitudes of chemical-analysis errors are not environmentally significant to NADP data users. Overall precision of the precipitation-monitoring system used by the NADP/NTN was estimated by evaluation of samples from collocated monitoring sites at CA99, CO08, and NH02. Precision defined by the median of the absolute percent difference (MAE) was estimated to be approximately 10 percent or less for calcium, magnesium, sodium, chloride, nitrate, sulfate, specific conductance, and sample volume. The MAE values for ammonium and hydrogen-ion concentrations were estimated to be less than 10 percent for CA99 and NH02 but nearly 20 percent for ammonium concentration and about 17 percent for hydrogen-ion concentration for CO08. As in past years, the variability in the collocated-site data for sam

Scientific Investigations Report

Evaluation of candidate rain gages for upgrading precipitation measurement tools for the National Atmospheric Deposition Program

The National Atmospheric Deposition Program (NADP) was established in 1977 to investigate atmospheric deposition and its effects on the environment. Since its establishment, precipitation records have been obtained at all NADP sites using a gage developed approximately 50 years ago-the Belfort 5-780 mechanical rain gage. In 1998 and 1999, a study was done by the U.S. Geological Survey to evaluate four recently developed, technologically advanced rain gages as possible replacement candidates for the mechanical gage currently (2002) in use by the NADP. The gage types evaluated were the Belfort 3200, Geonor T-200, ETI Noah II, and the OTT PLUVIO. The Belfort 5-780 was included in the study to compare the performance of the rain gage currently (2002) used by NADP to the performance of the more recently developed gages. As a reference gage, the NovaLynx Model 260-2510 National Weather Service type stick gage also was included in the study. Two individual gages of each type were included in the study to evaluate precision between gages of the same type. A two-phase evaluation was completed. Phase I consisted of indoor bench tests with known amounts of simulated rainfall applied in 20 individual tests. Phase II consisted of outdoor testing by collecting precipitation during a 26-week period near Bay St. Louis, Mississippi. The ETI Noah II, OTT PLUVIO, and NovaLynx stick gages consistently recorded depths more commensurate with the amounts of applied simulated rainfall in Phase I testing than the Geonor T-200, Belfort 5-780, and Belfort 3200 gages. Gages where both the median difference between the measured and applied simulated rainfall and the interquartile range of all of their measured minus applied simulated rainfall differences were small (less than or equal to 0.01 inch) were judged to have performed very well in Phase I testing. The median and interquartile-range values were 0.01 inch or less for each of the ETI Noah II gages, OTT PLUVIO gages, and NovaLynx stick gages. The performance of the Geonor T-200 and Belfort 3200 gages was affected by technical problems during Phase I testing. As part of the evaluation of Phase II results, the average weekly precipitation totals obtained from the Belfort 5-780 gages and from each of the gages under consideration as possible replacements for the Belfort 5-780 gage were all compared with the average precipitation weekly totals obtained from two NovaLynx stick gages. The median absolute differences between a particular gage model and the NovaLynx stick reference gage for the 26 weeks of outdoor testing ranged from 0.04 inch for the ETI Noah II and OTT PLUVIO gages to 0.06 inch for the Geonor T-200. The total absolute difference between a particular gage type and the reference gage ranged from 1.23 inches for the Belfort 5-780 to 1.83 inches for the Geonor T-200 gages. Because the Belfort 3200 gages were inoperable for most of the Phase II testing, it is not meaningful to include the results from that gage type in a calculation of median or total absolute differences. The OTT PLUVIO proved to be the most reliable gage in Phase I and II testing, operating trouble free over the duration of the study.

Water-Resources Investigations Report

External quality-assurance results for the National Atmospheric Deposition Program/National Trends Network, 1997-99

Five external quality-assurance programs were operated by the U.S. Geological Survey for the National Atmospheric Deposition Program/ National Trends Network (NADP/NTN) during 1997 through 1999: the intersite-comparison program, the blind-audit program, the field- audit program, the interlaboratory-comparison program, and the collocated-sampler program. The intersite-comparison program assesses the accuracy of pH and specific-conductance determinations made by NADP/NTN site operators. In two 1997 intersite-comparison studies, 83.7 and 85.8 percent of the pH determinations met the NADP/NTN accuracy goals, whereas 97.3 and 92.4 percent of the specific-conductance determinations met the NADP/NTN accuracy goals. The percentage of pH and specific-conductance determinations that met the accuracy goals in 1998 were, for the most part, higher than in 1997. In two 1998 studies, 90.9 and 90.3 percent of the pH determinations met the accuracy goals compared to 94.7 and 96.0 percent of the specific- conductance measurements meeting the accuracy goals. In one 1999 intersite-comparison study, 89.5 percent and 99.4 percent of pH and specific- conductance determinations, respectively, met the NADP/NTN accuracy goals. The blind-audit program evaluates the effects of routine sample handling, processing, and shipping on the analytical bias and precision of weekly precipitation samples. A portion of the blind-audit sample subject to the normal onsite handling and processing of a weekly precipitation sample is referred to as the bucket portion, whereas the portion receiving only minimal handling is referred to as the bottle portion. Positive bias in regard to blind-audit results indicates that the bucket portion has a higher concentration than the bottle portion. The paired t-test for the 1997 through 1999 blind- audit data indicates that routine sample handling, processing, and shipping introduced a positive bias (a=0.05) for calcium and chloride and a negative bias (cz=0.05) for hydrogen ion. During 1997 through 1999, the median paired differences between the bucket and bottle portions ranged from 0.00 milligram per liter for nitrate and ammonium to +0.010 milligram per liter for both chloride and sulfate. The median paired difference between the bucket and bottle portions for hydrogen ion was -1.086 microequivalents per liter, whereas for specific conductance, the median paired difference between the bucket and bottle portions was -0.200 microsiemen per centimeter during 1997 through 1999. Surface-chemistry effects due to variable amounts of precipitation contacting prewashed sample-collection and shipping-container surfaces were studied in the blind-audit program by using three different sample volumes. The sample- collection and shipping containers used for the blind-audit study were obtained from the site operator's supply and could have been used for precipitation samples. Results of a Kruskal-Wallis analysis of variance test of the relation between paired blind-audit sample differences in units of concentration and sample volume were statistically significant for magnesium, chloride, sulfate, and hydrogen ion during 1997 through 1999. Before 1994, at least 5 of the 10 analytes displayed a statistically significant difference between paired blind-audit differences in units of concentration and sample volume, supporting the premise that chemical reactions between the 13-liter bucket shipping container (primarily the butadiene o-ring lid of the shipping container) and the sample, which resulted in an increasing loss of hydrogen ion with increasing volume, have been eliminated by the new l-liter bottle sample- shipping protocol. The field-audit program measures the effects of field exposure, handling, and processing on the chemistry of NADP/NTN precipitation samples. In the field-audit program, the site operator is instructed to process and submit a quality- control sample following a standard 7-day, Tuesday-to-Tuesday sampling period with no

Water-Resources Investigations Report

Laboratory performance in the Sediment Laboratory Quality-Assurance Project, 1996-98

This report describes the results of the first 3 years of an ongoing study of sediment laboratories used by the U.S. Geological Survey (USGS). The sediment laboratories currently in operation constitute the entire USGS national laboratory system for sediment analyses. As with all environmental data, physical sediment data can be expected to contain a certain amount of difference, whether the difference resulted from the collecting, transporting, or analyzing of the sample. Because it is important to know how each laboratory is performing, the USGS initiated the Sediment Laboratory Quality-Assurance (SLQA) project in August 1996. From August 1996 through June 1998, five studies were made, the results of which are the basis of this report. The focus of the project is on quantitative analyses done on water-sediment mixtures to derive suspended-sediment concentrations, sediment-mass determinations, and sand/fine separations. For the purpose of this report, all mass determinations are net values—the tare weight of the container is excluded. The fine-size material is defined as particles sieved to a size of less than 62 micrometers (µm) and sand-size material is defined as particles sieved to a size of between 63 and 125 µm. Also, in this report, class 1 samples are defined as samples containing 50 to 100 milligrams (mg) of fine-size material, class 2 samples are defined as samples containing 101 to 300 mg of fine-size material, and class 3 samples are defined as samples containing 2,200 to 3,200 mg of fine-size material. In studies 96-1 through 98-1, the amount of sand added to each sample ranged from 9 to 28 percent of the mass of fine-size material in each sample class. Analytical results from all sediment quality-control samples are compiled and statistically summarized by the USGS, Branch of Quality Systems, both on an intra- and interlaboratory basis. When evaluating these data, the reader needs to keep in mind that every measurement has an error component associated with it. It is premature to use the data from the first five SLQA studies to judge any of the laboratories as performing in an unacceptable manner. There were, however, some notable differences in the results for the 12 laboratories that participated in the five SLQA studies. For example, the overall median percent difference for suspended-sediment concentration on an individual laboratory basis ranged from –18.04 to –0.33 percent. Five of the 12 laboratories had an overall median percent difference for suspended-sediment concentration of –2.02 to –0.33 percent. There was less variability in the median difference for the measured fine-size material mass. The overall median percent difference for fine-size material mass ranged from –10.11 to –4.27 percent. Except for one laboratory, the median difference for fine-size material mass was within a fairly narrow range of –6.76 to –4.27 percent. The median percent difference for sand-size material mass differed among laboratories more than any other physical sediment property measured in the study. The overall median percent difference for the sand-size material mass ranged from –1.49 percent to 26.39 percent. Five of the nine laboratories that do sand/fine separations had overall median percent differences that ranged from –1.49 to 2.98 percent for sand-size material mass. Careful review of the data reveals that certain laboratories consistently produced data within statistical control limits for some or all of the physical sediment properties measured in this study, whereas other laboratories occasionally produced data that exceeded the control limits.

Water-Resources Investigations Report

External quality-assurance results for the National Atmospheric Deposition Program/National Trends Network, 1995-96

The U.S. Geological Survey operated four external quality-assurance programs for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN) in 1995 and 1996: the intersite-comparison program, the blind-audit program, the interlaboratory- comparison program, and the collocated-sampler program. The intersite-comparison program assessed the precision and bias of pH and specific-conductance determinations made by NADP/NTN site operators. The analytical bias introduced during routine handling, processing, and shipping of wet-deposition samples and precision of analyte values was estimated using a blind-audit program. An interlaboratory-comparison program was used to evaluate differences between analytical results and to estimate the analytical precision of five North American laboratories that routinely analyzed wet deposition. A collocated-sampler program estimated the precision of the overall precipitation collection and analysis system from initial sample collection through final storage of the data. Results of two intersite-comparison studies completed in 1995 indicated 94.6 and 94.4 percent of the onsite pH determinations met the NADP/NTN accuracy goals, whereas 97.2 and 98.3 percent of the specific-conductance determinations were within the established limits. The percentages of onsite determinations that met the accuracy goals in 1996 were slightly less for both pH and specific-conductance than in 1995. In 1996, 93.2 and 87.5 percent of onsite pH determinations met the accuracy goals, whereas the percentage of onsite specific-conductance measurements that met the goals was 93.9 and 94.9 percent.The blind audit program utilizes a paired sample design to evaluate the effects of routine sample handling, processing and shipping on the chemistry of weekly precipitation samples. The portion of the blind audit sample subject to all of the normal onsite handling and processing steps of a regular weekly precipitation sample is referred to as the bucket portion, whereas the portion receiving only minimal handling is referred to as the bottle portion. Throughout the report, the term positive bias in regard to blind-audit results indicates that the bucket portion had a higher concentration than the bottle portion. The paired t-test of 1995 blind-audit data indicated that routine sample handling, processing, and shipping introduced a very small positive bias (a=0.05) for hydrogen ion and specific conductance and a slight negative bias (a =0.05) for ammonium and sodium. In 1995, the median paired differences between the bucket and bottle portions ranged from -0.02 milligram per liter for both ammonium and nitrate to +0.002 milligram per liter for calcium. Although the paired t-test indicated a very small positive bias for hydrogen ion, the median paired difference between the bucket and bottle portions was 0.00 microequivalents per liter, whereas for specific conductance, the median paired difference between the bucket and bottle portions was 0.200 microsiemens per centimeter in 1995. The paired t-test of blind-audit results in 1996 indicated statistically significant bias for 6 of the 10 analytes. Only chloride, nitrate, hydrogen ion, and specific conductance were not biased in 1996. However, the magnitude of the bias in 1996 was very small and only of limited importance from the viewpoint of an analytical chemist or data user. The median paired differences between the bucket and bottle portions ranged from -0.02 milligram per liter for both ammonium and chloride to +0.006 milligram per liter for calcium. For hydrogen ion, the median paired difference between the bucket and bottle portions was -0.357 microequivalent per liter; for specific conductance, the median paired difference between the bucket and bottle portions was 0.00 microsiemens per centimeter in 1996. Surface-chemistry effects due to different amounts of precipitation contacting the sample collection and shipping container surfac

Water-Resources Investigations Report