Improved method for the determination of nonpurgeable suspended organic carbon in natural water by silver filter filtration, wet chemical oxidation, and infrared spectrometry

Precision and accuracy are reported for the first time for the analysis of nonpurgeable suspended organic carbon by silver membrane filtration followed by wet chemical oxidation. A water sample is pressure filtered through a 0.45‐μm‐pore‐size, 47‐mm‐diameter silver membrane filter. The silver membrane filter then is cut into ribbons and placed in a flame‐sealable glass ampule. The organic material trapped on the membrane filter strips is acidified, purged with oxygen to remove inorganic carbonates and volatile organic compounds, and oxidized to carbon dioxide (CO 2 ) using phosphoric acid and potassium persulfate in the sealed glass ampule. The resulting CO 2 is measured by a nondispersive infrared CO 2 detector. The amount of CO 2 is proportional to the concentration of chemically oxidizable nonpurgeable organic carbon in the environmental water sample. The quantitation and method detection limit for routine analysis is 0.2 mg/L. The average percent recovery in five representative matrices was 97 ± 11%. The errors associated with sampling and sample preparation of nonpurgeable suspended organic carbon are also described.

Water Resources Research↗

Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory-Determination of nonpurgeable suspended organic carbon by wet-chemical oxidation and infrared spectrometry

Precision and accuracy results are described for the determination of nonpurgeable suspended organic carbon (SOC) by silver-filter filtration, wet-chemical oxidation, and infrared determination of hte resulting carbon dioxide (CO2) used at the U.S. Geological Survey's nationalWater Quality Laboratory. An aliquot of raw water isfiltered through a 0.45-micrometer silver filter. The trapped organic material is oxidized using phosphoric acid and potassium persulfate in a scaled glass ampule,and the rseulting CO2 is measured by an infrared CO2 detector. The amount of CO3 is proportional to the concentration of chemically oxidizable nonpurgeable organic carbon in the sample. The SOC method detection limit for routine analysis is 0.2 milligram per liter. The average percent recovery is 97.1 percent and the average standard deviation is 11 percent.

Open-File Report↗