Search USGSSearch

Geology topics

J.N. Huckins

Publications and source records attributed to J.N. Huckins.

At least 19 recordsLinked to original sources

Evaluation of the use of performance reference compounds in an oasis-HLB adsorbent based passive sampler for improving water concentration estimates of polar herbicides in freshwater

Passive samplers such as the Polar Organic Chemical Integrative Sampler (POCIS) are useful tools for monitoring trace levels of polar organic chemicals in aquatic environments. The use of performance reference compounds (PRC) spiked into the POCIS adsorbent for in situ calibration may improve the semiquantitative nature of water concentration estimates based on this type of sampler. In this work, deuterium labeled atrazine-desisopropyl (DIA-d5) was chosen as PRC because of its relatively high fugacity from Oasis HLB (the POCIS adsorbent used) and our earlier evidence of its isotropic exchange. In situ calibration of POCIS spiked with DIA-d5was performed, and the resulting time-weighted average concentration estimates were compared with similar values from an automatic sampler equipped with Oasis HLB cartridges. Before PRC correction, water concentration estimates based on POCIS data sampling ratesfrom a laboratory calibration exposure were systematically lower than the reference concentrations obtained with the automatic sampler. Use of the DIA-d5 PRC data to correct POCIS sampling rates narrowed differences between corresponding values derived from the two methods. Application of PRCs for in situ calibration seems promising for improving POCIS-derived concentration estimates of polar pesticides. However, careful attention must be paid to the minimization of matrix effects when the quantification is performed by HPLC-ESI-MS/MS. ?? 2010 American Chemical Society.

Environmental Science & Technology

Semivolatile organic compounds in residential air along the Arizona - Mexico border

Concerns about indoor air quality and the potential effects on people living in these environments are increasing as more reports about the toxicities and the potential indoor air exposure levels of household-use chemicals and chemicals fromhousingandfurnishingmanufactureinairarebeingassessed. Gas chromatography/mass spectrometry was used to confirm numerous airborne contaminants obtained from the analysis of semipermeable membrane devices deployed inside of 52 homes situated along the border between Arizona and Mexico. We also describe nontarget analytes in the organochlorine pesticide fractions of 12 of these homes; this fraction is also the most likelytocontainthebroadestscopeofbioconcentratablechemicals accumulated from the indoor air. Approximately 400 individual components were identified, ranging from pesticides to a wide array of hydrocarbons, fragrances such as the musk xylenes, flavors relating to spices, aldehydes, alcohols, esters and phthalate esters, and other miscellaneous types of chemicals. The results presented in this study demonstrate unequivocally that the mixture of airborne chemicals present indoors is far more complex than previously demonstrated. ?? 2009 American Chemical Society.

Environmental Science & Technology

Uptake rate constants and partition coefficients for vapor phase organic chemicals using semipermeable membrane devices (SPMDs)

To fully utilize semipermeable membrane devices (SPMDs) as passive samplers in air monitoring, data are required to accurately estimate airborne concentrations of environmental contaminants. Limited uptake rate constants (k ua ) and no SPMD air partitioning coefficient (K sa ) existed for vapor-phase contaminants. This research was conducted to expand the existing body of kinetic data for SPMD air sampling by determining k ua and K sa for a number of airborne contaminants including the chemical classes: polycyclic aromatic hydrocarbons, organochlorine pesticides, brominated diphenyl ethers, phthalate esters, synthetic pyrethroids, and organophosphate/organosulfur pesticides. The k ua s were obtained for 48 of 50 chemicals investigated and ranged from 0.03 to 3.07??m 3 ??g -1 ??d -1 . In cases where uptake was approaching equilibrium, K sa s were approximated. K sa values (no units) were determined or estimated for 48 of the chemicals investigated and ranging from 3.84E+5 to 7.34E+7. This research utilized a test system (United States Patent 6,877,724 B1) which afforded the capability to generate and maintain constant concentrations of vapor-phase chemical mixtures. The test system and experimental design employed gave reproducible results during experimental runs spanning more than two years. This reproducibility was shown by obtaining mean k ua values (n??=??3) of anthracene and p,p???-DDE at 0.96 and 1.57??m 3 ??g -1 ??d -1 with relative standard deviations of 8.4% and 8.6% respectively.

Atmospheric Environment

Comparison of the uptake of polycyclic aromatic hydrocarbons and organochlorine pesticides by semipermeable membrane devices and caged fish (Carassius carassius) in Taihu Lake, China

Uptake of polycyclic aromatic hydrocarbons (PAHs) and organochlorine pesticides (OCPs) by triolein-containing semipermeable membrane devices (SPMDs) and by crucian carp (Carassius carassius) was studied in Taihu Lake, a shallow, freshwater lake in China. Crucian carp and SPMDs were deployed side by side for 32 d. The first-order uptake rate constants of individual PAHs and OCPs for the two matrices were calculated and compared to relate the amounts of chemicals accumulated by the matrices to dissolved water concentrations. On a wet-weight basis, total concentrations of PAHs and OCPs in crucian carp fillets averaged 49.5 and 13.6 ng/g, respectively, after the 32-d exposure, whereas concentrations in whole SPMDs averaged 716.9 and 62.3 ng/g, respectively. The uptake rate constants of PAHs and OCPs by SPMDs averaged seven- and fivefold higher, respectively, than those for crucian carp; however, the patterns of uptake rate constants derived from test chemical concentrations in the crucian carp and SPMDs were similar. Although equilibrium was not reached for some PAHs and OCPs during the 32-d exposure period, a reasonably good correlation between the concentration factors (CFs) and octanol/water partition coefficient (K ow) values of PAHs and OCPs in SPMDs (r = 0.86, p < 0.001) was observed when potential sorption to dissolved organic carbon was taken into account. Similar efforts to correlate the CFs and Kow values of PAHs and OCPs in crucian carp (r = 0.75, p < 0.001) were less successful, likely because of PAH metabolism by finfish. Overall, the present results suggest that SPMDs may serve as a surrogate for contaminant monitoring with fish in freshwater lake environments. ?? 2007 SETAC.

Environmental Toxicology and Chemistry

Comparison of a novel passive sampler to standard water-column sampling for organic contaminants associated with wastewater effluents entering a New Jersey stream

Four water samples collected using standard depth and width water-column sampling methodology were compared to an innovative passive, in situ, sampler (the polar organic chemical integrative sampler or POCIS) for the detection of 96 organic wastewater-related contaminants (OWCs) in a stream that receives agricultural, municipal, and industrial wastewaters. Thirty-two OWCs were identified in POCIS extracts whereas 9-24 were identified in individual water-column samples demonstrating the utility of POCIS for identifying contaminants whose occurrence are transient or whose concentrations are below routine analytical detection limits. Overall, 10 OWCs were identified exclusively in the POCIS extracts and only six solely identified in the water-column samples, however, repetitive water samples taken using the standard method during the POCIS deployment period required multiple trips to the sampling site and an increased number of samples to store, process, and analyze. Due to the greater number of OWCs detected in the POCIS extracts as compared to individual water-column samples, the ease of performing a single deployment as compared to collecting and processing multiple water samples, the greater mass of chemical residues sequestered, and the ability to detect chemicals which dissipate quickly, the passive sampling technique offers an efficient and effective alternative for detecting OWCs in our waterways for wastewater contaminants.

New Jersey

Hazard assessment of a simulated oil spill on intertidal areas of the St. Lawrence River with SPMD-TOX

Phytoremediation in a simulated crude oil spill was studied with a “minimalistic” approach. The SPMD-TOX paradigm—a miniature passive sorptive device to collect and concentrate chemicals and microscale tests to detect toxicity—was used to monitor over time the bioavailability and potential toxicity of an oil spill. A simulated crude oil spill was initiated on an intertidal freshwater grass-wetland along the St. Lawrence River southwest of Quebec City, Quebec, Canada. Several phytoremediation treatments were investigated; to dissipate and ameliorate the spill, treatments included nutrient amendments with inorganic nitrogen sources (ammonium nitrate and sodium nitrate) and phosphate (super triple phosphate) with and without cut plants, with natural attenuation (no phytoremedial treatment) as a control. Sequestered oil residues were bioavailable in all oil-treated plots in Weeks 1 and 2. Interestingly, the samples were colored and fluoresced under ultraviolet light. In addition, microscale tests showed that sequestered residues were acutely toxic and genotoxic, as well as that they induced hepatic P 450 enzymes. Analysis of these data suggested that polycyclic aromatic hydrocarbons were among the bioavailable residues sequestered. In addition, these findings suggested that the toxic bioavailable fractions of the oil spill and degradation products dissipated rapidly over time because after the second week the water column contained no oil or detectable degradation products in this riverine intertidal wetland. SPMD-TOX revealed no evidence of bioavailable oil products in Weeks 4, 6, 8, and 12. All phytoremediation efforts appeared to be ineffective in changing either the dissipation rate or the ability to ameliorate the oil toxicity. SPMD-TOX analysis of the water columns from these riverine experimental plots profiled the occurrence, dissipation, and influence of phytoremediation on the bioavailability and toxicity of oil products (parent or degradation products).

Environmental Toxicology

Polar organic chemical integrative sampling and liquid chromatography- electrospray/ion-trap mass spectrometry for assessing selected prescription and illicit drugs in treated sewage effluents

The purpose of the research presented in this paper was twofold: (1) to demonstrate the coupling of two state-of-the-art techniques: a time-weighted polar organic chemical integrative sampler (POCIS) and microliquid chromatography–electrospray/ion-trap mass spectrometry and (2) to assess the ability of these methodologies to detect six drugs (azithromycin, fluoxetine, omeprazole, levothyroxine, methamphetamine, methylenedioxymethamphetamine [MDMA]) in a real-world environment, e.g., waste water effluent. In the effluent from three wastewater treatment plants (WWTPs), azithromycin was detected at concentrations ranging from 15 to 66 ng/L, which is equivalent to a total annual release of 1 to 4 kg into receiving waters. Detected and confirmed in the effluent from two WWTPs were two illicit drugs, methamphetamine and MDMA, at 2 and 0.5 ng/L, respectively. Although the ecotoxicologic significance of drugs in environmental matrices, particularly water, has not been closely examined, it can only be surmised that these substances have the potential to adversely affect biota that are continuously exposed to them even at very low levels. The potential for chronic effects on human health is also unknown but of increasing concern because of the multiuse character of water, particularly in densely populated, arid areas.

Archives of Environmental Contamination and Toxico

Comparisons of coarse and fine versions of two carbons for reducing the bioavailabilities of sediment-bound hydrophobic organic contaminants

Coarse (whole) and finely ground Ambersorb 1500 and coarse and fine coconut charcoal were compared as to their efficiencies in scavenging organic contaminants desorbed from sediment. Aqueous slurries of a test sediment spiked (1 ppm) with p,p???-DDE (DDE), 2,2???,5,5???-tetrachlorobiphenyl (TCB), naphthalene (NAP), or phenanthrene (PHEN), and containing 1% levels of the test carbons were treated by shaking at 35 ??C while exposed to clusters of low-density polyethylene membrane (detox spiders). Controls consisted of spiked sediments and detox spiders but no added carbon of any kind and thus represented unimpeded bioavailabilities (to the spiders). After the treatments - agitation periods from 2.5 to 60 h, depending on contaminant hydrophobicity - the exposed detox spiders were analyzed. The fine carbon of either type was more effective than its coarser variant in obstructing contaminant bioavailabilities. The finer variants of both carbons obstructed the bioavailabilities of NAP and PHEN equally well as did the coarser variants of both. Whole Ambersorb 1500 and coarse coconut charcoal were similarly ineffective in intercepting TCB and DDE. Ground Ambersorb 1500 obstructed virtually all bioavailability of all four contaminants and was far more effective than fine coconut charcoal in intercepting DDE and TCB. An additional experiment compared the effectiveness of ground Ambersorb 1500 and fine coconut charcoal in obstructing the bioavailabilities from sediment of a broad array of spiked organochlorine pesticides. The performance of ground Ambersorb 1500 was again found to be superior; the bioavailable levels of each of the 27 pesticides were markedly lower in the presence of ground Ambersorb 1500 than in the presence of fine coconut charcoal.

Chemosphere

Sequestration of priority pollutant PAHs from sediment pore water employing semipermeable membrane devices

Semipermeable membrane devices (SPMDs) were employed to sample sediment pore water in static exposure studies under controlled laboratory conditions using (control pond and formulated) sediments fortified with 15 priority pollutant polycyclic aromatic hydrocarbons (PPPAHs). The sediment fortification level of 750 ng/g was selected on the basis of what might be detected in a sediment sample from a contaminated area. The sampling interval consisted of 0, 4, 7, 14, and 28 days for each study. The analytical methodologies, as well as the extraction and sample cleanup procedures used in the isolation, characterization, and quantitation of 15 PPPAHs at different fortification levels in SPMDs, water, and sediment were reported previously (Williamson, M.S. Thesis, University of Missouri - Columbia, USA; Williamson et al., Chemosphere (This issue - PII: S0045-6535(02)00394-6)) and used for this project. Average (mean) extraction recoveries for each PPPAH congener in each matrix are reported and discussed. No procedural blank extracts (controls) were found to contain any PPPAH residues above the method quantitation limit, therefore, no matrix interferences were detected. The focus of this publication is to demonstrate the ability to sequester environmental contaminants, specifically PPPAHs, from sediment pore water using SPMDs and two different types of fortified sediment.

Chemosphere

Stabilized liquid membrane device (SLMD) for the passive, integrative sampling of labile metals in water

A stabilized liquid membrane device (SLMD) is described for potential use as an in situ, passive, integrative sampler for cadmium (Cd), cobalt (Co), copper (Cu), nickel (Ni), lead (Pb), and zinc (Zn) in natural waters. The SLMD (patent pending) consists of a 2.5-cm-wide by 15-cm-long strip of low-density polyethylene (LDPE) layflat tubing containing 1 mL of an equal mixture (v/v) of oleic acid (cis-9-octadecenoic acid) and EMO-8Q (7-[4-ethyl-1-methyloctyl]-8-quinolinol). The reagent mixture continuously diffuses to the exterior surface of the LDPE membrane, and provides for sequestration of several divalent metals for up to several weeks. Depending on sampler configuration, concentration factors of several thousand can be realized for these metal ions after just a few days. In addition to in situ deployment, the SLMD may be useful for laboratory determination of labile metal species in grab samples. Methods for minimizing the effects of water flow on the sampling rate are currently under investigation.

Water, Air, & Soil Pollution

Development of the permeability/performance reference compound approach for in situ calibration of semipermeable membrane devices

Permeability/performance reference compounds (PRCs) are analytically noninterfering organic compounds with moderate to high fugacity from semipermeable membrane devices (SPMDs) that are added to the lipid prior to membrane enclosure. Assuming that isotropic exchange kinetics (IEK) apply and that SPMD-water partition coefficients are known, measurement of PRC dissipation rate constants during SPMD field exposures and laboratory calibration studies permits the calculation of an exposure adjustment factor (EAF). In theory, PRC-derived EAF ratios reflect changes in SPMD sampling rates (relative to laboratory data) due to differences in exposure temperature, membrane biofouling, and flow velocity-turbulence at the membrane surface. Thus, the PRC approach should allow for more accurate estimates of target solute/vapor concentrations in an exposure medium. Under some exposure conditions, the impact of environmental variables on SPMD sampling rates may approach an order of magnitude. The results of this study suggest that most of the effects of temperature, facial velocity-turbulence, and biofouling on the uptake rates of analytes with a wide range of hydrophobicities can be deduced from PRCs with a much narrower range of hydrophobicities. Finally, our findings indicate that the use of PRCs permits prediction of in situ SPMD sampling rates within 2-fold of directly measured values.

Environmental Science & Technology

Comparing polychlorinated biphenyl concentrations and patterns in the Saginaw River using sediment, caged fish, and semipermeable membrane devices

Three techniques of assessing bioavailable polychlorinated biphenyls (PCBs) in the Saginaw River, MI, were compared: sediments, caged fish, and semipermeable membrane devices (SPMDs). SPMDs and caged fish were placed in the river for 28 days at five sites where sediments were also sampled. The samples were analyzed for PCB congeners to determine concentrations and patterns. Total PCB concentrations ranged from 33 to 280 ng/g (dry weight) in sediments, 46 to 290 ng/g (wet weight) in caged fish, and 77 to 790 ng/g in SPMDs. Previously reported rates of PCB accumulation by SPMDs were used to estimate aqueous concentrations from the PCB concentrations detected in the SPMDs. Sediment-water partition coefficients were used to estimate aqueous PCB concentrations from sediment. Steady-state bioconcentration factors and depuration rate constants were used to estimate dissolved PCB concentrations from caged channel catfish. Relative PCB patterns from the SPMDs, caged fish, and sediment were compared using principal components analysis. SPMD and sediment samples provide complementary information. Sediments reflect long-term accumulation and weathering, while SPMDs integrate water concentrations only during the sampling period. Because of higher water solubilities of lower-chlorinated PCBs these predominate in the SPMDs as compared to in the fish and sediments. Contaminant profile differences between caged fish and SPMDs are likely due to metabolism and depuration of certain PCB congeners by fish.Three techniques of assessing bioavailable polychlorinated biphenyls (PCBs) in the Saginaw River, Ml, were compared: sediments, caged fish, and semipermeable membrane devices (SPMDs). SPMDs and caged fish were placed in the river for 28 days at five sites where sediments were also sampled. The samples were analyzed for PCB congeners to determine concentrations and patterns. Total PCB concentrations ranged from 33 to 280 ng/g (dry weight) in sediments, 46 to 290 ng/g (wet weight) in caged fish, and 77 to 790 ng/g in SPMDs. Previously reported rates of PCB accumulation by SPMDs were used to estimate aqueous concentrations from the PCB concentrations detected in the SPMDs. Sediment-water partition coefficients were used to estimate aqueous PCB concentrations from sediment. Steady-state bioconcentration factors and depuration rate constants were used to estimate dissolved PCB concentrations from caged channel catfish. Relative PCB patterns from the SPMDs, caged fish, and sediment were compared using principal components analysis. SPMD and sediment samples provide complementary information. Sediments reflect long-term accumulation and weathering, while SPMDs integrate water concentrations only during the sampling period. Because of higher water solubilities of lower-chlorinated PCBs these predominate in the SPMDs as compared to in the fish and sediments. Contaminant profile differences between caged fish and SPMDs are likely due to metabolism and depuration of certain PCB congeners by fish.At five sites in the Saginaw River, MI, PCB concentrations were determined in the summer of 1993 using three methods: sediment analysis, concentrations in caged fish, and concentrations in semipermeable membrane devices (SPMDs). On average, total PCB concentrations in the SPMDs were twice those found in caged fish, and the SPMD-to-fish concentration ratios of di-, tri-, tetra-, and pentaCB homologues were 10.0, 3.0, 2.5, and 1.4, respectively. Average concentrations in the sediments were approximately half those in the SPMDs, and the caged fish showed a greater preponderance of higher log octanol-water partition coefficient PCBs similar to the sediment pattern. On average, the water PCB concentrations estimated from sediment concentrations were five times higher than those calculated from SPMDs and three times higher than those estimated from caged fish. The total PCB concentrations in sediment, caged fish, and SPMDs ranged 33-280, 46-290, and 77-790 ng/g, respectiv

Environmental Science & Technology

Considerations involved with the use of semipermeable membrane devices for monitoring environmental contaminants

Semipermeable membrane devices (SPMDs) are used with increasing frequency, and throughout the world as samplers of organic contaminants. The devices can be used to detect a variety of lipophilic chemicals in water, sediment/soil, and air. SPMDs are designed to sample nonpolar, hydrophobic chemicals. The maximum concentration factor achievable for a particular chemical is proportional to its octanol–water partition coefficient. Techniques used for cleanup of SPMD extracts for targeted analytes and for general screening by full-scan mass spectrometry do not differ greatly from techniques used for extracts of other matrices. However, SPMD extracts contain potential interferences that are specific to the membrane–lipid matrix. Procedures have been developed or modified to alleviate these potential interferences. The SPMD approach has been demonstrated to be applicable to sequestering and analyzing a wide array of environmental contaminants including organochlorine pesticides, polychlorinated biphenyls, polycyclic aromatic hydrocarbons, polychlorinated dioxins and dibenzofurans, selected organophosphate pesticides and pyrethroid insecticides, and other nonpolar organic chemicals. We present herein an overview of effective procedural steps for analyzing exposed SPMDs for trace to ultra-trace levels of contaminants sequestered from environmental matrices.

Journal of Chromatography A

Selective removal of organic contaminants from sediments: A methodology for toxicity identification evaluations (TIEs)

Aqueous slurries of a test sediment spiked with dibenz[a,h]anthracene, 2,4,5,2′,4′,5′-hexachlorobiphenyl, p,p′-DDE, or phenanthrene were subjected to decontamination experimentation. The spiked sediments were agitated at elevated temperatures for at least 96 h in the presence of either of the two contaminant-absorbing media: clusters of polyethylene membrane or lipid-containing semipermeable membrane devices (SPMDs). The effects of treatment temperature and surface area of media on the removal of contaminants were explored. This work is part of a larger methodology for whole-sediment toxicity identification evaluation (TIE). A method is being sought that is capable of detoxifying sediments with respect to organic contaminants while leaving toxicity attributable to inorganic contaminants unaffected.

Chemosphere

An approach for assessment of water quality using semipermeable membrane devices (SPMDs) and bioindicator tests

As an integral part of our continued development of water quality assessment approaches, we combined integrative sampling, instrumental analysis of widely occurring anthropogenic contaminants, and the application of a suite of bioindicator tests as a specific part of a broader survey of ecological conditions, species diversity, and habitat quality in the Santa Cruz River in Arizona, USA. Lipid-containing semipermeable membrane devices (SPMDs) were employed to sequester waterborne hydrophobic chemicals. Instrumental analysis and a suite of bioindicator tests were used to determine the presence and potential toxicological relevance of mixtures of bioavailable chemicals in two major water sources of the Santa Cruz River. The SPMDs were deployed at two sites; the effluent weir of the International Wastewater Treatment Plant (IWWTP) and the Nogales Wash. Both of these systems empty into the Santa Cruz River and the IWWTP effluent is a potential source of water for a constructed wetland complex. Analysis of the SPMD sample extracts revealed the presence of organochlorine pesticides (OCs), polychlorinated biphenyls (PCBs), and polycyclic aromatic hydrocarbons (PAHs). The bioindicator tests demonstrated increased liver enzyme activity, perturbation of neurotransmitter systems and potential endocrine disrupting effects (vitellogenin induction) in fish exposed to the extracts. With increasing global demands on limited water resources, the approach described herein provides an assessment paradigm applicable to determining the quality of water in a broad range of aquatic systems.

Chemosphere

A passive integrative sampler for mercury vapor in air and neutral mercury species in water

A passive integrative mercury sampler (PIMS) based on a sealed polymeric membrane was effective for the collection and preconcentration of Hg0. Because the Hg is both oxidized and stabilized in the PIMS, sampling intervals of weeks to months are possible. The effective air sampling rate for a 15 x 2.5 cm device was about 21-equivalents/day (0.002 m3/day) and the detection limit for 4-week sampling was about 2 ng/m3 for conventional ICP-MS determination without clean-room preparation. Sampling precision was ??? 5% RSD for laboratory exposures, and 5-10% RSD for field exposures. These results suggest that the PIMS could be useful for screening assessments of Hg contamination and exposure in the environment, the laboratory, and the workplace. The PIMS approach may be particularly useful for applications requiring unattended sampling for extended periods at remote locations. Preliminary results indicate that sampling for dissolved gaseous mercury (DGM) and potentially other neutral mercury species from water is also feasible. Rigorous validation of the sampler performance is currently in progress. (C) 1999 Elsevier Science Ltd.A passive integrative mercury sampler (PIMS) based on a sealed polymeric membrane was effective for the collection and preconcentration of Hg0. Because the Hg is both oxidized and stabilized in the PIMS, sampling intervals of weeks to months are possible. The effective air sampling rate for a 15??2.5 cm device was about 21-equivalents/day (0.002 m3/day) and the detection limit for 4-week sampling was about 2 ng/m3 for conventional ICP-MS determination without clean-room preparation. Sampling precision was ???5% RSD for laboratory exposures, and 5-10% RSD for field exposures. These results suggest that the PIMS could be useful for screening assessments of Hg contamination and exposure in the environment, the laboratory, and the workplace. The PIMS approach may be particularly useful for applications requiring unattended sampling for extended periods at remote locations. Preliminary results indicate that sampling for dissolved gaseous mercury (DGM) and potentially other neutral mercury species from water is also feasible. Rigorous validation of the sampler performance is currently in progress.

Chemosphere - Global Change Science

Determination of uptake kinetics (sampling rates) by lipid-containing semipermeable membrane devices (SPMDs) for polycyclic aromatic hydrocarbons (PAHs) in water

The use of lipid-containing semipermeable membrane devices (SPMDs) is becoming commonplace, but very little sampling rate data are available for the estimation of ambient contaminant concentrations from analyte levels in exposed SPMDs. We determined the aqueous sampling rates (R(s)s; expressed as effective volumes of water extracted daily) of the standard (commercially available design) 1-g triolein SPMD for 15 of the priority pollutant (PP) polycyclic aromatic hydrocarbons (PAHs) at multiple temperatures and concentrations. Under the experimental conditions of this study, recovery- corrected R(s) values for PP PAHs ranged from ???1.0 to 8.0 L/d. These values would be expected to be influenced by significant changes (relative to this study) in water temperature, degree of biofouling, and current velocity- turbulence. Included in this paper is a discussion of the effects of temperature and octanol-water partition coefficient (K(ow)); the impacts of biofouling and hydrodynamics are reported separately. Overall, SPMDs responded proportionally to aqueous PAH concentrations; i.e., SPMD R(s) values and SPMD-water concentration factors were independent of aqueous concentrations. Temperature effects (10, 18, and 26 ??C) on Rs values appeared to be complex but were relatively small.The use of lipid-containing semipermeable membrane devices (SPMDs) is becoming commonplace, but very little sampling rate data are available for the estimation of ambient contaminant concentrations from analyte levels in exposed SPMDs. We determined the aqueous sampling rates (Rss; expressed as effective volumes of water extracted daily) of the standard (commercially available design) 1-g triolein SPMD for 15 of the priority pollutant (PP) polycyclic aromatic hydrocarbons (PAHs) at multiple temperatures and concentrations. Under the experimental conditions of this study, recovery-corrected Rs values for PP PAHs ranged from ???1.0 to 8.0 L/d. These values would be expected to be influenced by significant changes (relative to this study) in water temperature, degree of biofouling, and current velocity-turbulence. Included in this paper is a discussion of the effects of temperature and octanol-water partition coefficient (KOW); the impacts of biofouling and hydrodynamics are reported separately. Overall, SPMDs responded proportionally to aqueous PAH concentrations; i.e., SPMD RS values and SPMD-water concentration factors were independent of aqueous concentrations. Temperature effects (10, 18, and 26??C) on RS values appeared to be complex but were relatively small.

Environmental Science & Technology

Removal of organic contaminant toxicity from sediments - Early work toward development of a toxicity identification evaluation (TIE) method

Work was performed to determine the feasibility of selectively detoxifying organic contaminants in sediments. The results of this research will be used to aid in the development of a scheme for whole-sediment toxicity identification evaluations (TIEs). The context in which the method will be used inherently restricts the treatments to which the sediments can be subjected: Sediments cannot be significantly altered physically or chemically and the presence and bioavailabilities of other toxicants must not be changed. The methodological problem is daunting because of the requirement that the detoxification method be relatively fast and convenient together with the stipulation that only innocuous and minimally invasive treatments be used. Some of the experiments described here dealt with degrees of decontamination (i.e., detoxification as predicted from instrumental measurements) of spiked sediments rather than with degrees of detoxification as gauged by toxicity tests (e.g., 48-h toxicity tests with amphipods). Although the larger TIE scheme itself is mostly outside the scope of this paper, theoretical aspects of bioavailability and of the desorption of organic contaminants from sediments are discussed.

Chemosphere