Search USGSSearch

Geology topics

J.F. Blakey

Publications and source records attributed to J.F. Blakey.

9 recordsLinked to original sources

Chemical and bacteriological quality of water at selected sites in the San Antonio area, Texas, August 1968-January 1975

Urban development on or adjacent to the recharge zone of the Edwards aquifer is causing concern about the possible pollution of ground water in the aquifer, which is the principal source of water supply for the San Antonio area. Water-quality data for many wells and springs and for selected sites on streams that cross the recharge zone of the aquifer are being collected to provide background information and to detect any current pollution of ground water in the area. Water from the Edwards aquifer is very hard and of the calcium bicarbonate type. The concentrations of dissolved solids in samples from wells and springs ranged from about 200 to 470 mg/1 (milligrams per liter); the chloride and sulfate concentrations ranged from 6.5 to 62 mg/1 and from 0.0 to 65 mg/1, respectively. The nitrate and phosphate contents of the ground water ranged from 0.0 to 15 mg/1 and from 0.00 to 0. 37 mg/1. The concentrations of these and other constituents show that the chemical quality of water in the Edwards aquifer has not been degraded significantly by domestic, industrial, or agricultural effluents. However, variations in the number of coliforms, the concentrations of nitrate and phosphate, and the presence of fecal coliforms and fecal streptococci in samples from some wells show that fecal pollution is reaching the aquifer. Most of these wells, which are located in or just downdip from the recharge zone, are poorly sealed or inadequately cased. The areal variation in the locations of these wells indicates that pollution of ground water in the aquifer is very localized. Prllution results principally from runoff from the land surface and from effluent from septic tanks which enters the aquifer through fractures in the recharge zone or which infiltrates through the thin soil into poorly sealed or inadequately cased wells in or adjacent to the recharge zone. Trace amounts of several pesticides have been detected in samples from two wells in the San Antonio area. Field investigations showed the source of pesticides in these wells to be. surface drainage that entered the wellbores. Water-quality data collected at sites on streams that cross the recharge zone of the Edwards aquifer show the chemical composition of surface water to be very similar to that of ground water in the area. Water in most streams is very hard and of the calcium bicarbonate type. Limited data on the bacteriological quality show that coliforms were present at each of the site sampled and that fecal coliforms and fecal streptococci were present at most sites. Although the number of these bacteria varied greatly in both time and place, their density in samples from most sites were low for untreated surface water.

Texas

A network for continuous monitoring of water quality in the Sabine River basin, Texas and Louisiana

The proposed water-quality network for the Sabine River Basin of Texas and Louisiana consists of nine monitoring stations, a central control station, a slave-central station, and a leased-line telecommunications system. This monitoring network would provide continuous transmission of water-quality data to the office of the water manager. Level I operations at a proposed site would monitor current and potential problems, water-quality changes in subreaches of streams, and water-quality trends in time and place. Level II operations would monitor current or potential problems only. An optimum system would require Level I operations at all nine stations. A minimum system would require Level II operations at most of the stations.

Lousianna, Texas

An evaluation of water-quality records for Texas streams

Chemical data for 12 streamflow-sampling stations in Texas, each having from 8 to 24 years of available historical records, were analyzed to determine functional relationships between concentrations of the major inorganic constituents and specific conductance or stream discharge. Regression equations for each station were derived by using data for an identical 5-year period; the remaining record served as independent test data for checking the adequacy of the functions on the basis of continued specific-conductance determinations as an index variable. Daily solute concentrations and loads at a sampling site were simulated, and monthly and annual averages were computed by using daily records of specific conductance in conjunction with the regression equations. Simulated annual mean concentrations of most individual solutes and dissolved solids averaged within 10-20 percent of comparable concentrations determined from the composited chemical analyses, although systematic biases were detected in results for some of the relationships used in the simulation. Results of the evaluation of the 12 stations indicated that regression equations, using specific conductance as the independent variable, can be used as an alternative to composite analyses for calculation of solute concentrations and loads in Texas streams and is a flexible system that can be applied with sufficient accuracy to satisfy most anticipated needs for data.

Texas

Geology and water quality at selected locations in the San Antonio area, Texas, Progress Report, 1969

The Edwards aquifer is the principal source of water supply for the San Antonio area. Increasing urban development on or adjacent to the recharge area of the aquifer is causing great concern because of possible pollution of the ground water. A detailed map of the surface geology has been prepared for areas where the greatest threat of pollution exists. Water-quality data are being collected throughout the San Antonio area to provide background reference information and to detect any current pollution of the ground water in the Edwards and associated limestones. Mapping of the surface geology will continue in areas where waste waters may be recharging the aquifer. Water-quality data will be collected at additional sites, and some sites will be resampled where pollution may be occurring or where more background data are needed.

Open-File Report

Base-flow studies Nueces River, Texas quantity and quality, November 23-25, 1964

An investigation was made by the U.S. Geological Survey, under a cooperative agreement with the Texas Water Development Board, to determine the changes in quantity and chemical quality of the base flow of the Nueces River in a 52.2-mile reach beginning at U.S. Highway 90 and extending to the crossing of Farm Road 1025 north of Crystal City. Knowledge of the changes in quantity and chemical quality of base flow is necessary for any evaluation of the effectiveness of the river channel in conveying water released from potential upstream reservoirs. The investigation was made November 23-25, 1964, during a period when evaporation and transpiration were small and the discharge past the stream-gaging station, Nueces River below Uvalde, was constant. Floods of September 1964 contributed considerably to the recharge of the alluvium in the reach investigated, resulting in a higher than average base flow.

Texas