Search USGS⌕ Search

Geology topics

J. S. Kane

Publications and source records attributed to J. S. Kane.

6 recordsLinked to original sources

Analytical performance of a low-gas-flow torch optimized for inductively coupled plasma atomic emission spectrometry

An inductively coupled Ar plasma (ICP), generated in a lowflow torch, was investigated by the simplex optimization technique for simultaneous, multielement, atomic emission spectrometry (AES). The variables studied included forward power, observation height, gas flow (outer, intermediate, and nebulizer carrier) and sample uptake rate. When the ICP was operated at 720-W forward power with a total gas flow of 5 L/min, the signal-to-background ratios (S/B) of spectral lines from 20 elements were either comparable or inferior, by a factor ranging from 1.5 to 2, to the results obtained from a conventional Ar ICP. Matrix effect studies on the Ca-PO4 system revealed that the plasma generated in the low-flow torch was as free of vaporizatton-atomizatton interferences as the conventional ICP, but easily ionizable elements produced a greater level of suppression or enhancement effects which could be reduced at higher forward powers. Electron number densities, as determined via the series until line merging technique, were tower ht the plasma sustained in the low-flow torch as compared with the conventional ICP. ?? 1984 American Chemical Society.

Analytical Chemistry↗

Reference samples for use in analytical geochemistry: their availability, preparation, and appropriate use

A large number of certified and other reference samples are available for use in analytical geochemistry. Certified materials are preferred, but of much more limited availability than other reference samples for most geochemical applications. The availability of rock, sediment, soil, water, and plant reference samples is outlined; ore and mineral separate reference samples are not included in the discussion. The preparation of these materials, including the establishment of certified or recommended concentrations, is then reviewed. It is shown that comparable quality can be achieved for both certified and recommended concentrations, though it has not always been achieved in the past. Finally, the most appropriate ways to use reference samples in quality control and instrumental calibration are discussed.

Journal of Geochemical Exploration↗

Comparison of several analytical methods for the determination of tin in geochemical samples as a function of tin speciation

Accurate and precise determinations of tin in geological materials are needed for fundamental studies of tin geochemistry, and for tin prospecting purposes. Achieving the required accuracy is difficult because of the different matrices in which Sn can occur (i.e. sulfides, silicates and cassiterite), and because of the variability of literature values for Sn concentrations in geochemical reference materials. We have evaluated three methods for the analysis of samples for Sn concentration: graphite furnace atomic absorption spectrometry (HGA-AAS) following iodide extraction, inductively coupled plasma atomic emission spectrometry (ICP-OES), and energy-dispersive X-ray fluorescence (EDXRF) spectrometry. Two of these methods (HGA-AAS and ICP-OES) required sample decomposition either by acid digestion or fusion, while the third (EDXRF) was performed directly on the powdered sample. Analytical details of all three methods, their potential errors, and the steps necessary to correct these errors were investigated. Results showed that similar accuracy was achieved from all methods for unmineralized samples, which contain no known Sn-bearing phase. For mineralized samples, which contain Sn-bearing minerals, either cassiterite or stannous sulfides, only EDXRF and fusion ICP-OES methods provided acceptable accuracy. This summary of our study provides information which helps to assure correct interpretation of data bases for underlying geochemical processes, regardless of method of data collection and its inherent limitations. ?? 1989.

Chemical Geology↗

Optimisation of flame parameters for simultaneous multi-element atomic absorption spectrometric determination of trace elements in rocks

A study is described that identifies the optimum operating conditions for the accurate determination of Co, Cu, Mn, Ni, Pb, Zn, Ag, Bi and Cd using simultaneous multi-element atomic absorption spectrometry. Accuracy was measured in terms of the percentage recoveries of the analytes based on certified values in nine standard reference materials. In addition to identifying optimum operating conditions for accurate analysis, conditions resulting in serious matrix interferences and the magnitude of the interferences were determined. The listed elements can be measured with acceptable accuracy in a lean to stoicheiometric flame at measurement heights ???5-10 mm above the burner.

Journal of Analytical Atomic Spectrometry↗