Search USGS⌕ Search

Geology topics

Harald Edens

Publications and source records attributed to Harald Edens.

3 recordsLinked to original sources

Impulsive volcanic plumes generate volcanic lightning and vent discharges: A statistical analysis of Sakurajima volcano in 2015

The origin of electrical activity accompanying volcanic ash plumes is an area of heightened interest in volcanology. However, it is unclear how intense an eruption needs to be to produce lightning flashes as opposed to “vent discharges,” which represent the smallest scale of electrical activity. This study targets 97 carefully monitored plumes <3 km high from Sakurajima volcano in Japan, from June 1 to 7, 2015. We use multiparametric measurements from sensors including a nine-station lightning mapping array and an infrared camera to characterize plume ascent. Findings demonstrate that the impulsive, high velocity plumes (>55 m/s) were most likely to create vent discharges, whereas lightning flashes occurred in plumes with high volume flux. We identified conditions where volcanic lightning occurred without detectable vent discharges, highlighting their independent source mechanisms. Our results imply that plume dynamics govern the charging for volcanic lightning, while the characteristics of the source explosion control vent discharges.

Sakurajima volcano↗

Investigating the origin of continual radio frequency impulses during explosive volcanic eruptions

Volcanic lightning studies have revealed that there is a relatively long‐lasting source of very high frequency radiation associated with the onset of explosive volcanic eruptions that is distinct from radiation produced by lightning. This very high frequency signal is referred to as “continual radio frequency (CRF)” due to its long‐lasting nature. The discharge mechanism producing this signal was previously hypothesized to be caused by numerous, small (10–100 m) leader‐forming discharges near the vent of the volcano. To test this hypothesis, a multiparametric data set of electrical and volcanic activity occurring during explosive eruptions of Sakurajima Volcano in Japan was collected from May to June 2015. Our observations show that a single CRF impulse has a duration on the order of 160 ns (giving an upper limit on discharge length of 10 m) and is distinct from near‐vent lightning discharges that were on the order of 30 m in length. CRF impulses did not produce discernible electric field changes and occurred in the absence of a net static electric field. Lightning mapping data and infrared video observations of the eruption column showed that CRF impulses originated from the gas thrust region of the column. These observations indicate that CRF impulses are not produced by small, leader‐forming discharges but rather are more similar to a streamer discharge, likely on the order of a few meters in length.

Sakurajima Volcano↗

Lightning and electrical activity during the 2006 eruption of Augustine Volcano

Lightning and other electrical activity were measured during the 2006 eruption of Augustine Volcano. We found two phases of the activity, the explosive phase corresponding to the explosive eruptions and the plume phase. We classified the lightning into three types, vent discharges, near-vent lightning, and plume lightning. Vent discharges are small, 10 to 100 m sparks, that occur at rate as great as 10,000 s-1 at the mouth of the volcano during the energetic explosive eruptions. The vent discharges were observed six different times. Near-vent lightning appears to develop upward from the volcanic cone into the developing column during explosions. This lightning is small, in the range of 1 to 7 km, and short, 0.01 to 0.1 s. The behavior of the near-vent lightning indicates an overall positive charge in the ejecta. The plume lightning resembled intracloud thunderstorm lightning. Often it was branched, spanned more than 10 km, and lasted more than 0.5 s.

Alaska↗