Search USGSSearch

Geology topics

Guillaume Dramais

Publications and source records attributed to Guillaume Dramais.

5 recordsLinked to original sources

Improving hydroacoustic methods for monitoring suspended-sand flux and grain size in sediment-laden rivers

Suspended-sand concentration and grain-size data in rivers provide valuable information on the catchment's dynamics for scientists and river managers. Producing continuous measurements of suspended-sand concentrations remains a scientific challenge due to their high spatial and temporal variability. Traditional methods such as sediment-rating curves may be highly uncertain, and optical turbidity is insensitive to coarse particles when there are many fine particles. Surrogate hydroacoustic methods aim to improve sand concentration measurements. These single- or dual-frequency acoustic methods use acoustic attenuation and/or backscatter to estimate fine-sediment (i.e., silt and clay) and/or sand concentration and possibly grain size. New methods have recently been developed and applied in rivers exhibiting a wide range of sediment conditions in North America but not independently tested elsewhere by other researchers. In this article, we apply, adapt and evaluate hydroacoustic methods to continuously estimate suspended-sand concentration and grain size in an Alpine river with high suspended-sediment concentrations. From the example of the River Isère at Grenoble Campus, France, we show that the hydroacoustic methods adapted to local conditions may yield valuable sand concentration estimates consistent with traditional measurements. Compared with prior knowledge, limited additional information on the grain size can be obtained due to high uncertainties. Hydroacoustic concentration estimates are more sensitive to real changes in concentration at the event scale than traditional rating-curve methods that relate concentration to discharge only. These findings open the perspective for facilitated sand concentration monitoring at a higher temporal resolution with decreased field work.

Grenoble Campus

River suspended-sand flux computation with uncertainty estimation using water samples and high-resolution ADCP measurements

Measuring suspended-sand fluxes in rivers remains a scientific challenge due to their high spatial and temporal variability. To capture the vertical and lateral gradients of concentration in the cross-section, measurements with point samples are performed. However, the uncertainty related to these measurements is rarely evaluated, as few studies of the major sources of error exist. Therefore, the aim of this study is to develop a method to determine the cross-sectional sand flux and estimate its uncertainty. This SDC (for sand discharge computing) method combines suspended-sand concentrations from point samples with ADCP (acoustic Doppler current profiler) high-resolution depth and velocity measurements. The MAP (for multitransect averaged profile) method allows obtaining an average of several ADCP transects on a regular grid, including the unmeasured areas. The suspended-sand concentrations are integrated vertically by fitting a theoretical exponential suspended-sand profile to the data using Bayesian modeling. The lateral integration is based on the water depth as a proxy for the local bed shear stress to evaluate the bed concentration and sediment diffusion along the river cross-section. The estimation of uncertainty combines ISO standards and semi-empirical methods with a Bayesian approach to estimate the uncertainty due to the vertical integration. The new method is applied to data collected in four rivers under various hydro-sedimentary conditions: the Colorado, Rhône, Isère, and Amazon rivers, with computed flux uncertainties ranging between 18 % and 32 %. The relative difference between the suspended-sand flux in 21 cases calculated with the proposed SDC method compared to the International Organization for Standardization (ISO) 4363 standard method ranges between − 40 % and + 23 %. This method that comes with a flexible, open-source code is the first to propose an applicable uncertainty estimation that could be adapted to other flux computation methods.

Earth Surface Dynamics

Mapping 2-D bedload rates throughout a sand-bed river reach from high-resolution acoustical surveys of migrating bedforms

This paper introduces a method for determining spatially-distributed, 2-D bedload rates using repeat, high-resolution surveys of the bed topography. As opposed to existing methods, bedform parameters and bedload rates are computed from bed elevation profiles interpolated along the local bedform velocities. The bedform velocity fields are computed applying Large-Scale Particle Image Velocimetry, initially developed for surface velocity measurements, to pairs of successive Digital Elevation Models (DEMs). The bathymetry data are interpolated along the direction of each bedform velocity and the mean height of the closest bedform is computed. The dune shape factor is also evaluated along each bedform direction of travel. The local bedload fluxes can be computed by multiplying the bedform velocity by its mean height averaged over the successive two DEMs, and they can be time-averaged over a series of DEM pairs. This method is applied to a high-resolution acoustical survey of an approximately 300 m long by 40 m wide reach of the Colorado River in Grand Canyon upstream from Diamond Creek, USA. The repeat period was about 6–10 min and bed elevation was interpolated every 0.25 m. The obtained results provide insight to the spatial and temporal variability of bedload rates, bedform parameters and bedload fluxes through cross-sections. The method can be applied to other repeated acoustical surveys of river reaches provided that the space and time resolutions are high enough to capture the local movement of bedforms.

Arizona

Field investigation of sub-isokinetic sampling by the US D-96-type suspended-sediment sampler and its effect on suspended-sediment measurements

Collection of accurate suspended-sediment data using depth-integrating samplers requires that they operate isokinetically, that is, that they sample at the local stream velocity unaffected by the presence of the suspended-sediment sampler. Sub-isokinetic suspended-sediment sampling causes grain-size dependent positive biases in the suspended-sediment concentration measured by the suspended-sediment sampler. Collapsible bag suspended-sediment samplers like the US D-96 and the lighter US D-96-A1 depth-integrating samplers have shown a tendency to sample sub-isokinetically under low stream velocities (below ~3.5 feet per second), colder water temperatures, and longer sampling durations. Previous work concluded that the time-dependent decrease in the intake efficiency of the US D-96-type sampler could be partially overcome by increasing the venting of water from the sampler cavity by shortening the sampler tray. The standard-length sampler tray partially blocks the rear vent hole; shortening the sampler tray effectively increases the area of the sampler-cavity rear vent hole. This previous work showed that removing the partial blockage of the rear vent hole caused by the sampler tray resulted in both an increase in intake efficiency and a decrease in the positive bias in measured suspended-sand concentration. Herein, a series of tests were conducted on the Colorado River in Arizona using different modifications to a US D-96-A1 sampler to see if physical enlargement of the rear vent hole would produce further improvements in intake efficiency. Results from these tests show that physical enlargement of the rear vent hole, beyond that already effectively achieved by shortening the sampler tray, did not result in any further improvement in intake efficiency. However, these tests also indicated that physically increasing the area of the rear vent hole did not affect the suspended-sediment data collected by the US D-96-A1 sampler. Furthermore, comparisons of suspended-sediment data collected using the US D-96-A1 sampler and the isokinetic US P-61-A1 point-integrating sampler show that the suspended-sediment data collected by the US D-96-type sampler can be accurate in certain circumstances despite the tendency of this sampler to sample sub-isokinetically over the entire depth of a sampling vertical. We surmise that this result could arise from the US D-96-A1 sampler collecting sample isokinetically when the water-sediment mixture enters the nozzle, but that the water-sediment mixture only enters the nozzle intermittently while the sampler transits a sampling vertical.

Arizona

A physically based method of combining ADCP velocity data with point samples to compute suspended-sand discharge -- Application to the Rhone River, France

Measuring suspended-sand flux in rivers is a challenge since sand concentrations are highly variable in time and space throughout a river cross section. Most of the present methodologies rely on point or depth-integrated sampling (Nolan et al., 2005, Topping et al., 2016). The standard method estimates mean concentration and multiply it by discharge to compute the suspended-sand discharge. Here, we demonstrate methods of combining point suspended-sediment samples with ADCP (Acoustic Doppler Current Profiler) high-resolution depth and velocity measurements to improve vertical and lateral integration of concentration and flux. A preliminary version of this method is applied to data collected in the Rhône River in Lyon, France, during a 10-year flood in January 2018. Two options for vertically integrating the measured suspended-sediment concentrations were tested whereas lateral integration was based on nearest-neighbor interpolation only, as a baseline option. Sand flux results are similar, thus suggesting that vertical integration options may be less critical than lateral integration options that will be implemented and tested in future work.

Rhone River