Search USGSSearch

Geology topics

G.S. Bodvarsson

Publications and source records attributed to G.S. Bodvarsson.

5 recordsLinked to original sources

Field investigation into unsaturated flow and transport in a fault: Model analyses

Results of a fault test performed in the unsaturated zone of Yucca Mountain, Nevada, were analyzed using a three-dimensional numerical model. The fault was explicitly represented as a discrete feature and the surrounding rock was treated as a dual-continuum (fracture-matrix) system. Model calibration against seepage and water-travel-velocity data suggests that lithophysal cavities connected to fractures can considerably enhance the effective fracture porosity and therefore retard water flow in fractures. Comparisons between simulation results and tracer concentration data also indicate that matrix diffusion is an important mechanism for solute transport in unsaturated fractured rock. We found that an increased fault-matrix and fracture-matrix interface areas were needed to match the observed tracer data, which is consistent with previous studies. The study results suggest that the current site-scale model for the unsaturated zone of Yucca Mountain may underestimate radionuclide transport time within the unsaturated zone, because an increased fracture-matrix interface area and the increased effective fracture porosity arising from lithophysal cavities are not considered in the current site-scale model. ?? 2004 Published by Elsevier B.V.

Journal of Contaminant Hydrology

Estimating recharge at Yucca Mountain, Nevada, USA: Comparison of methods

Obtaining values of net infiltration, groundwater travel time, and recharge is necessary at the Yucca Mountain site, Nevada, USA, in order to evaluate the expected performance of a potential repository as a containment system for high-level radioactive waste. However, the geologic complexities of this site, its low precipitation and net infiltration, with numerous mechanisms operating simultaneously to move water through the system, provide many challenges for the estimation of the spatial distribution of recharge. A variety of methods appropriate for arid environments has been applied, including water-balance techniques, calculations using Darcy's law in the unsaturated zone, a soil-physics method applied to neutron-hole water-content data, inverse modeling of thermal profiles in boreholes extending through the thick unsaturated zone, chloride mass balance, atmospheric radionuclides, and empirical approaches. These methods indicate that near-surface infiltration rates at Yucca Mountain are highly variable in time and space, with local (point) values ranging from zero to several hundred millimeters per year. Spatially distributed net-infiltration values average 5 mm/year, with the highest values approaching 20 mm/year near Yucca Crest. Site-scale recharge estimates range from less than 1 to about 12 mm/year. These results have been incorporated into a site-scale model that has been calibrated using these data sets that reflect infiltration processes acting on highly variable temporal and spatial scales. The modeling study predicts highly non-uniform recharge at the water table, distributed significantly differently from the non-uniform infiltration pattern at the surface.

Hydrogeology Journal

Hydrology of Yucca Mountain, Nevada

Yucca Mountain, located in southern Nevada in the Mojave Desert, is being considered as a geologic repository for high-level radioactive waste. Although the site is arid, previous studies indicate net infiltration rates of 5-10 mm yr-1 under current climate conditions. Unsaturated flow of water through the mountain generally is vertical and rapid through the fractures of the welded tuffs and slow through the matrix of the nonwelded tuffs. The vitric-zeolitic boundary of the nonwelded tuffs below the potential repository, where it exists, causes perching and substantial lateral flow that eventually flows through faults near the eastern edge of the potential repository and recharges the underlying groundwater system. Fast pathways are located where water flows relatively quickly through the unsaturated zone to the water table. For the bulk of the water a large part of the travel time from land surface to the potential repository horizon (~300 m below land surface) is through the interlayered, low fracture density, nonwelded tuff where flow is predominately through the matrix. The unsaturated zone at Yucca Mountain is being modeled using a three-dimensional, dual-continuum numerical model to predict the results of measurements and observations in new boreholes and excavations. The interaction between experimentalists and modelers is providing confidence in the conceptual model and the numerical model and is providing researchers with the ability to plan further testing and to evaluate the usefulness or necessity of further data collection.

Reviews of Geophysics

Pre-exploitation state of the Ahuachapán geothermal field, El Salvador

The lithology and structural features of the Ahuachapán geothermal area and their impact on the movement of cold and hot fluids within the system are described, as well as the development and evaluation of the natural state model of the field. Four major lithologic units are present in Ahuachapán and three major aquifers have been identified; flow patterns and zones of fluid mixing were located on the basis of temperature and geochemical data from wells and surface manifestations. Geologic structures control the heat and fluid recharge and the flow within the reservoir. Modeling studies suggest, in agreement with field data, an overall average transmissivity of 25–35 darcy-meters, and indicate that the system is recharged by waters with temperatures greater than 250°C. The total thermal throughflow for the Ahuachapán reservoir in the unexploited state is estimated to be about 250 MW t .

Geothermics

Changes in thermodynamic conditions of the Ahuachapán reservoir due to production and injection

Since large-scale exploitation of the Ahuachapán reservoir began in 1975 large changes in the reservoir thermodynamic conditions have occurred. Drawdown of up to 15 bars and significant temperature changes have been observed in the wellfield. Temperatures have declined due to boiling in the reservoir in response to the pressure drawdown; localized and minor cooling due to reinjection of spent geothermal fluids have also been observed. There are indications of cold fluid influx deep into the reservoir from the west and north. Reservoir temperatures show that a significant amount of hot fluid recharge comes to the wellfield from the southeast, and temperatures also indicate that the recharge rate has increased with time as pressure declines in the reservoir. Chemical analyses of the produced fluids show that most wells are fed by a mixture of geothermal fluids and cooler, less-saline waters. The cold water inflow has increased due to exploitation, as demonstrated by decreased salinity of the produced fluids.

Geothermics