Search USGSSearch

Geology topics

Earl P. Truitt

Publications and source records attributed to Earl P. Truitt.

3 recordsLinked to original sources

Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory-Determination of ammonium plus organic nitrogen by a Kjeldahl digestion method and an automated photometric finish that includes digest cleanup by gas diffusion

The National Water Quality Laboratory (NWQL) determined ammonium plus organic nitrogen (Kjeldahl nitrogen) by using semiautomated, block digester methods for filtered and whole-water samples from 1986 until October 1, 1991. During that time, phosphorus was determined by a persulfate digestion method. In 1991, projected increases in demand for both tests by the U.S. Geological Survey?s National Water-Quality Assessment Program led the NWQL to develop and validate methods for determining both analytes in a common digest. This report describes a rapid and accurate method to determine Kjeldahl nitrogen. The batch, high-temperature (block digester), Hg (II)-catalyzed digestion step used in the new methods I-2515-91/4515-91 is similar to U.S. Geological Survey methods I-2552-85/4552-85 and U.S. Environmental Protection Agency method 351.2 except that sample and reagent volumes are halved. Prepared digests are desolvated at 220 degrees Celsius (oC) and digested at 370oC in separate block digesters set at these temperatures, rather than in a single, temperatureprogrammed block digester. This approach permits 40 calibrants, reference materials, and samples to be digested and resolvated in about an hour. Ammonium ions originally present in samples, along with those released during the digestion step, are determined photometrically by an automated, salicylatehypochlorite Berthelot reaction procedure at a rate of 90 tests per hour. About 100 microliters of digest are required per determination. The upper concentration level is 10 milligrams per liter (mg/L) with a method detection level of 0.05 mg/L. Repeatability for a sample containing about 4.1 mg/L of Kjeldahl nitrogen in a high suspended-solids matrix is 3.1 percent. Between-day precision for the same sample is 4.8 percent. A gas diffusion cell in the air-segmented continuous flow analyzer eliminates particulates and ions that otherwise would interfere in the photometric finish. A singlechannel analyzer can process the resolvated digests from two pairs of block digesters each hour. Statistical analysis of paired data for about 1,500 samples determined by U.S. Geological Survey methods I-2552-85/4552- 85 and I-2515-91/4515-91 during method validation revealed a median concentration difference between the former and the latter methods of about 0.1 mg-N/L. This result was expected because digestion blank concentrations (nearly equal to 0.1 mg/L) were not subtracted from concentrations reported by methods I-2552-85/4552-85. A 10-year record of National Water Quality Laboratory Kjeldahl nitrogen blind blank concentration data also supports a step-change decrease in Kjeldahl nitrogen concentrations of about 0.1 mg/L after methods I-2552-85/4552-85 were replaced by methods I-2515-91/4515-91 on October 1, 1991. Somewhat larger concentration differences between the two methods were observed for a subset of about 350 samples with nitrate plus nitrite concentrations greater than 1 mg-N/L.

Open-File Report

U.S. Geological Survey nutrient preservation experiment: Nutrient concentration data for surface-, ground-, and municipal-supply water samples and quality-assurance samples

This report is a compilation of analytical results from a study conducted at the U.S. Geological Survey, National Water Quality Laboratory (NWQL) in 1992 to assess the effectiveness of three field treatment protocols to stabilize nutrient concentra- tions in water samples stored for about 1 month at 4C. Field treatments tested were chilling, adjusting sample pH to less than 2 with sulfuric acid and chilling, and adding 52 milligrams of mercury (II) chloride per liter of sample and chilling. Field treatments of samples collected for determination of ammonium, nitrate plus nitrite, nitrite, dissolved Kjeldahl nitrogen, orthophosphate, and dissolved phosphorus included 0.45-micrometer membrane filtration. Only total Kjeldahl nitrogen and total phosphorus were determined in unfiltered samples. Data reported here pertain to water samples collected in April and May 1992 from 15 sites within the continental United States. Also included in this report are analytical results for nutrient concentrations in synthetic reference samples that were analyzed concurrently with real samples.

Open-File Report

Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory-Determination of the total phosphorus by a Kjeldahl digestion method and an automated colorimetric finish that includes dialysis

A method to determine total phosphorus (TP) in the same digests prepared for total Kjeldahl nitrogen (TKN) determinations is desribed. The batch, high-temperature (block digester), HG(II)-catalyzed digestion step is similar to U.S. Geological Survey methods I-2552-85/I-4552-85 and U.S. Environmental Protection Agency method 365.4 except that sample and reagent volumes are halved. Prepared digests are desolvated at 220 degrees Celsius and digested at 370 degrees Celsius in separate block digesters set at these temperatures, rather than in a single, temperature-programmed block digester. This approach is used in the method escribed here, which permits 40 calibrants, reference waters, and smaples to be digested and resolvated in about an hour. Orthophosphate ions originally present in samples, along with those released during the digestion step, are determined colorimetrically at a rate of 90 tests per hour by an automated version of the phosphoantimonylmolybdenum blue procedure. About 100 microliters of digest are required per determination. The upper concentration limit is 2 milligrams per liter (mg/L) with a method detection limt of 0.01 mg/L. Repeatability for a sample containing approximately 1.6 mg/L of TP in a high suspended-solids matrix is 0.7 percent. Between-day precision for the same sample is 5.0 percent. A dialyzer in the air-segmented continuous flow analyzer provides on-line digest cleanup, eliminated particulates that otherwise would interfere in the colorimetric finish. An single-channel analyzer can process the resolvated digests from two pairs of block digesters each hour. Paired t-test analysis of TP concentrations for approximately 1,600 samples determined by the new method (U.S. Geologial Survey methods I-2610-91 and I-4610-91) and the old method (U.S. Geological Survey methods I-2600-85 and I-4600-85) revealed positive bias in the former of 0.02 to 0.04 mg/L for surface-water samples in agreement with previous studies. Concentrations of total phosphorus detemrined for ground-water samples by both methods were statistically equivalent.

Open-File Report