Search USGSSearch

Geology topics

Dwight Q. Tanner

Publications and source records attributed to Dwight Q. Tanner.

23 records · Page 2Linked to original sources

Data-collection methods, quality-assurance data, and site considerations for total dissolved gas monitoring, lower Columbia River, Oregon and Washington, 2000

Excessive total dissolved gas pressure can cause gas-bubble trauma in fish downstream from dams on the Columbia River. In cooperation with the U.S. Army Corps of Engineers, the U.S. Geological Survey collected data on total dissolved gas pressure, barometric pressure, water temperature, and probe depth at eight stations on the lower Columbia River from the John Day forebay (river mile 215.6) to Camas (river mile 121.7) in water year 2000 (October 1, 1999, to September 30, 2000). These data are in the databases of the U.S. Geological Survey and the U.S. Army Corps of Engineers. Methods of data collection, review, and processing, and quality-assurance data are presented in this report.

Oregon, Washington

The effects of calcium magnesium acetate (CMA) deicing material on the water quality of Bear Creek, Clackamas County, Oregon, 1999

This report presents the results of a study by the U.S. Geological Survey, done in cooperation with the Oregon Department of Transportation (ODOT), to evaluate the effects of the highway deicing material, calcium magnesium acetate (CMA), on the water quality of Bear Creek, in the Cascade Range of Oregon. ODOT began using CMA (an alternative deicer that has fewer adverse environmental effects than road salt) in the mid-1990s and began this study with the USGS to ensure that there were no unexpected effects on the water quality of Bear Creek. Streamflow, precipitation, dissolved oxygen, pH, specific conductance, and water temperature were measured continuously through the 1998?99 winter. There was no measurable effect of the application of CMA to Highway 26 on the biochemical oxygen demand (BOD), calcium concentration, or magnesium concentration of Bear Creek and its tributaries. BOD was small in all of the water samples, some of which were collected before CMA application, and some of which were collected after application. Five-day BOD values ranged from 0.1 milligrams per liter to 1.5 milligrams per liter, and 20-day BOD values ranged from 0.2 milligrams per liter to 2.0 milligrams per liter. Dissolved copper concentrations in a small tributary ditch on the north side of Highway 26 exceeded the U.S. Environmental Protection Agency aquatic life criteria on three occasions. These exceedances were probably not caused by the application of CMA because (1) one of the samples was a background sample (no recent CMA application), and (2) dissolved copper was not detected in Bear Creek water samples to which CMA was added during laboratory experiments.

Oregon

Total dissolved gas, barometric pressure, and water temperature data, lower Columbia River, Oregon and Washington, 1996

Increased levels of total dissolved gas pressure can cause gas-bubble trauma in fish downstream from dams on the Columbia River. In cooperation with the U.S. Army Corps of Engineers, the U.S. Geological Survey collected data on total dissolved gas pressure, barometric pressure, water temperature, and dissolved oxygen pressure at 11 stations on the lower Columbia River from the John Day forebay (river mile 215.6) to Wauna Mill (river mile 41.9) from March to September 1996. Methods of data collection, review, and processing are described in this report. Summaries of daily minimum, maximum, and mean hourly values are presented for total dissolved gas pressure, barometric pressure, and water temperature. Hourly values for these parameters are presented graphically. Dissolved oxygen data are not presented in this report because the quality-control data show that the data have poor precision and high bias. Suggested changes to monitoring procedures for future studies include (1) improved calibration procedures for total dissolved gas and dissolved oxygen to better define accuracy at elevated levels of supersaturation and (2) equipping dissolved oxygen sensors with stirrers because river velocities at the shoreline monitoring stations probably cannot maintain an adequate flow of water across the membrane surface of the dissolved oxygen sensor.

Oregon, Washington

Water quality of the lower Columbia River Basin: Analysis of current and historical water-quality data through 1994

The lower Columbia River Basin includes the river basins draining into the Columbia River below Bonneville Dam&mdash;the largest of which is the Willamette River. This report presents the results of a study by the U.S. Geological Survey, done in cooperation with the Lower Columbia River Bi-State Water- Quality Program, to describe the water-quality conditions in the lower Columbia River Basin by interpreting historical data collected and data collected in 1994. Historical water-quality data spanning more than 50 years and comprising more than 200 parameters were collated for interpretation in this report. The U.S. Geological Survey, the Oregon Department of Environmental Quality, and the Washington Department of Ecology collected water-quality data at 10 sites in the lower Columbia River Basin from January to December of 1994. Water-quality constituents measured in 1994 were screened against U.S. Environmental Protection Agency (EPA) and State guidelines. Arsenic, a human carcinogen, was detected in 15 of 16 samples in the lower Columbia River, but was not detected in any of the sampled tributaries. All 15 arsenic detections had concentrations that exceeded both the EPA ambient water-quality criteria for the protection of human health and the EPA human-health advisories for drinking water. Chromium was detected at all four Columbia River sites&mdash;most frequently in the Columbia River at Hayden Island. None of the chromium concentrations detected, however, exceeded water-quality criteria or guidelines. Measurements of suspended trace-element concentrations (trace-element concentrations associated with the suspended-sediment fraction) showed that the suspended form is the dominant transport phase for aluminum, iron, and manganese, whereas the dissolved form is the dominant transport phase for arsenic, barium, chromium, and copper. On the basis of tributary loads during summer low-flow months, sources of suspended silver, nickel, aluminum, and antimony exist in the lower Columbia River Basin, whereas the sources of suspended zinc and arsenic exist outside of the lower basin. Twenty organic compounds were detected of the 47 compounds analyzed for this study. None of the organic compounds measured exceeded EPA&rsquo;s ambient water-quality criteria or drinking-water guidelines. The Willamette River at Portland had the largest number of detections, and all 20 compounds were detected at one time or another at that site. The largest concentrations of the agricultural pesticides, atrazine, metolachlor, and simazine were detected in the Willamette River, where they were detected in 93, 86, 93 percent, respectively, of the samples collected. The highest concentrations of atrazine in the Willamette River were associated with the spring application and fall runoff periods. Both historical and current data showed that the highest water temperatures in the lower Columbia River Basin are present during August. For water years 1977&ndash;81 in the Columbia River at Bradwood (river mile 38.9), 75 percent of the daily mean water temperatures during August exceeded 20 degrees Celsius, a &ldquo;special condition&rdquo; criterion for the State of Washington. The special condition criterion was exceeded at four sites on the lower Columbia River during July and August, 1994&mdash;a period coinciding with season-high air temperatures and low streamflow. Trend tests using data from 1974 to 1994 showed significant (r < 0.05) upward trends for water temperature at the Columbia River at Warrendale and the Willamette River at Portland. Concentrations of dissolved oxygen and total dissolved gas were above saturation levels during high stormflows in the lower Columbia River and the Willamette River during 1994. The high concentrations of total dissolved gas in the Columbia River exceeded Oregon and Washington State standards of 110 percent of saturation and were caused by spilling water at the Columbia River dams. Aquatic life in the lower Columbia River Basin was not subjected to low dissolved-oxygen concentrations. Comparison of dissolved-oxygen concentrations in the Willamette River from 1949&ndash;58 to 1972&ndash;94 showed a significant increase in dissolved-oxygen concentrations during the low-streamflow months of summer. Trend tests showed significant (r < 0.05) downward trends from 1973 to 1994 for three constituents at the Columbia River at Warrendale: phosphorus in unfiltered water, total dissolved solids, and specific conductance. These trends may be a consequence of more conservative agricultural practices in the area upstream from Warrendale.

Oregon

Assessment of water quality, nutrients, algal productivity, and management alternatives for low-flow conditions, South Umpqua River basin, Oregon, 1990-92

This report is an evaluation of the effects of nutrient loading on water quality in the South Umpqua River Basin. The study was done by the U.S. Geological Survey in cooperation with Douglas County, Oregon. Five wastewater-treatment plants were shown to contribute less than 15 percent of the flow, but more than 90 percent of the nitrogen and phosphorus, in the South Umpqua River during low streamflows in summer. These nutrient inputs were associated with, and largely responsible for, the dense growth of periphytic algae that covered the rocky channel and produced biomass values as large as 340 grams of ash-free dry weight per square meter. The nighttime respiration of periphytic algae caused violations of the Oregon water-quality standard, which requires a dissolved oxygen concentration of at least 90 percent of saturation, at most sites along the South Umpqua River. Photosynthesis by algae during daylight resulted in many exceedances of the Oregon pH standard of 8.5. Net productivity, calculated from hourly measurements of dissolved oxygen concentrations, was as much as 3.8 grams of oxygen per square meter per day. The magnitude of productivity increased with increases in dissolved inorganic nitrogen concentration and load. The large amount of nutrient uptake by algae resulted in lowered nutrient concentrations downstream from nutrient point sources. Management alternatives for the South Umpqua River Basin include several methods to reduce nutrient concentrations and loads. The reduction of dissolved-inorganic-nitrogen and soluble- reactive-phosphorus loads from wastewater- treatment-plant effluent would reduce the frequency of violations of water-quality standards. Flow augmentation probably would decrease water-quality problems in the river, but it is difficult to predict the magnitude of the effects of increased velocity and decreased temperature on algal growth. Land application and storage of wastewater-treatment-plant effluent during the summer months would reduce the input of nutrients from point sources. Three exceedances of the Oregon standard for fecal coliform of 200 colonies per 100 milliliters were associated with large streamflows, suggesting that nonpoint sources affect the river during periods of high runoff. Fecal-streptococcus counts were larger than historical values and require confirmation. Ammonia from wastewater-treatment-plant effluent, high pH values, and high temperatures present a potential for chronic ammonia toxicity in the lower reaches of the South Umpqua River; however, actual violations of standards for chronic concentrations were not detected because of diel fluctuations in pH and water temperature.

Oregon