Search USGS⌕ Search

Geology topics

Debbie W. Gordon

Publications and source records attributed to Debbie W. Gordon.

12 recordsLinked to original sources

Groundwater quality and groundwater levels in Dougherty County, Georgia, April 2020 through January 2023

The Upper Floridan aquifer is the uppermost reliable groundwater source in southwest Georgia. The aquifer lies on top of the Claiborne, Clayton, and Cretaceous aquifers, all of which exhibited water-level declines in the 1960s and 1970s. The U.S. Geological Survey has been working cooperatively with Albany Utilities to monitor groundwater quality and availability in these aquifers since 1977. Flow direction in the Upper Floridan aquifer is to the south and toward the Flint River. During the past 3 years, water levels varied above and below period-of-record median values. Water levels in the Upper Floridan aquifer were primarily above or at median levels during 2020 and 2021 and at or below median levels during 2022. Water levels in the Claiborne aquifer were above median levels, whereas water levels in the Clayton aquifer were at or below median levels, and in the Cretaceous aquifer system were close to median levels. During January 2021, eight wells were sampled for major ions, including nitrate plus nitrite as nitrogen (N). Nitrate plus nitrite as N concentrations ranged from 2.3 to 10.5 milligrams per liter (mg/L). During December 2021, seven wells were sampled for major ions, including nitrate plus nitrite as N. Nitrate plus nitrite as N concentrations ranged from 3.9 to 9.9 mg/L. During November 2022, eight wells were sampled for major ions, including nitrate plus nitrite as N. Nitrate plus nitrite as N concentrations ranged from 3.9 to 10.0 mg/L. Two wells were also sampled for per- and polyfluoroalkyl substances during November 2022.

Georgia↗

Groundwater quality and groundwater levels in Dougherty County, Georgia, April 2019 through March 2020

The Upper Floridan aquifer is the uppermost, reliable aquifer in southwest Georgia. The aquifer lies on top of the Claiborne, Clayton, and Cretaceous aquifers, all of which exhibited water level declines in the 1960s and 1970s. The U.S. Geological Survey has been working cooperatively with Albany Utilities to monitor groundwater quality and availability in these aquifers since 1977. During January 2020, nine wells were sampled—six for anions, metals, and nitrate plus nitrite as nitrogen, and three for anions, metals, and pesticides. Nitrate plus nitrite as nitrogen concentrations ranged from 2.4 milligrams per liter (mg/L) to 10.4 mg/L, and no pesticides were detected. Nitrate plus nitrite as nitrogen concentrations in well 12L277, open to the Upper Floridan aquifer, have been above the U.S. Environmental Protection Agency Maximum Contaminant Level of 10 mg/L for nitrates in drinking water since 2014. Flow direction in the Upper Floridan aquifer is to the south and toward the Flint River. Water levels varied during the past year above and below period of record median values. Water levels in the Upper Floridan aquifer were primarily above median levels. Water levels in the Claiborne aquifer were above median levels, whereas water levels in the Clayton and Cretaceous aquifers were below median levels.

Georgia↗

Groundwater conditions in Georgia, 2015–16

The U.S. Geological Survey collects groundwater data and conducts studies to monitor hydrologic conditions, define groundwater resources, and address problems related to water supply, water use, and water quality. In Georgia, water levels were monitored continuously at 157 wells during calendar years 2015 and 2016. Because of missing data or short periods of record (less than 5 years) for several of these wells, data for 147 wells are presented in this report. These wells include 15 in the surficial aquifer system, 18 in the Brunswick aquifer system and equivalent sediments, 59 in the Upper Floridan aquifer, 13 in the Lower Floridan aquifer and underlying units, 9 in the Claiborne aquifer, 1 in the Gordon aquifer, 8 in the Clayton aquifer, 16 in the Cretaceous aquifer system, 2 in Paleozoic-rock aquifers, and 6 in crystalline-rock aquifers. Data from the well network indicate that water levels generally rose during the 10-year period from 2007 through 2016, with water levels rising in 105 wells and declining in 31 wells; insufficient data prevented determination of a 10-year trend in 11 wells. Water levels declined over the long-term period of record at 80 wells, increased at 62 wells, and remained relatively constant at 5 wells. In addition to continuous water-level data, periodic water-level data were collected and used to construct potentiometric-surface maps for the Upper Floridan aquifer in the Brunswick–Glynn County area during October 2015 and October 2016 and in the Albany–Dougherty County area during December 2015 and November and December 2016. Periodic water-level measurements were also collected and used to construct potentiometric-surface maps for the Cretaceous aquifer system in the Augusta–Richmond County area during July 2015 and June 2016. In general, water levels in the Upper Floridan aquifer were higher during 2015 than during 2016 in the Brunswick–Glynn County and Albany–Dougherty County areas due to higher precipitation during 2015. Water levels were lower, however, during 2015 than during 2016 in the Cretaceous aquifer system in the Augusta–Richmond County area. In the Brunswick area, maps showing the chloride concentration of water in the Upper Floridan aquifer constructed using data collected from 33 wells during October 2015 and from 30 wells during October 2016 indicate that chloride concentrations remained above the U.S. Environmental Protection Agency’s secondary drinking-water standard in an approximately 2-square-mile area. During calendar years 2015–16, chloride concentrations generally were similar to those measured during 2012–14; however, some wells did show an increase in chloride concentration, likely due to increases in pumping.

Georgia↗

Hydrology of the Claiborne aquifer and interconnection with the Upper Floridan aquifer in southwest Georgia

The U.S. Geological Survey conducted a study, in cooperation with the Georgia Environmental Protection Division, to define the hydrologic properties of the Claiborne aquifer and evaluate its connection with the Upper Floridan aquifer in southwest Georgia. The effort involved collecting and compiling hydrologic data from the aquifer in subarea 4 of southwestern Georgia. Data collected for this study include borehole geophysical logs in 7 wells, and two 72-hour aquifer tests to determine aquifer properties. The top of the Claiborne aquifer extends from an altitude of about 200 feet above the North American Vertical Datum of 1988 (NAVD 88) in Terrell County to 402 feet below NAVD 88 in Decatur County, Georgia. The base of the aquifer extends from an altitude of about 60 feet above NAVD 88 in eastern Sumter County to about 750 feet below NAVD 88 in Decatur County. Aquifer thickness ranges from about 70 feet in eastern Early County to 400 feet in Decatur County. The transmissivity of the Claiborne aquifer, determined from two 72-hour aquifer tests, was estimated to be 1,500 and 700 feet squared per day in Mitchell and Early Counties, respectively. The storage coefficient was estimated to be 0.0006 and 0.0004 for the same sites, respectively. Aquifer test data from Mitchell County indicate a small amount of leakage occurred during the test. Groundwater-flow models suggest that the source of the leakage was the underlying Clayton aquifer, which produced about 2.5 feet of drawdown in response to pumping in the Claiborne aquifer. The vertical hydraulic conductivity of the confining unit between the Claiborne and Clayton aquifers was simulated to be about 0.02 foot per day. Results from the 72-hour aquifer tests run for this study indicated no interconnection between the Claiborne and overlying Upper Floridan aquifers at the two test sites. Additional data are needed to monitor the effects that increased withdrawals from the Claiborne aquifer may have on future water resources.

Georgia↗

Hydrologic conditions, recharge, and baseline water quality of the surficial aquifer system at Jekyll Island, Georgia, 2012-13

An increase of groundwater withdrawals from the surficial aquifer system on Jekyll Island, Georgia, prompted an investigation of hydrologic conditions and water quality by the U.S. Geological Survey during October 2012 through December 2013. The study demonstrated the importance of rainfall as the island’s main source of recharge to maintain freshwater resources by replenishing the water table from the effects of hydrologic stresses, primarily evapotranspiration and pumping. Groundwater-flow directions, recharge, and water quality of the water-table zone on the island were investigated by installing 26 shallow wells and three pond staff gages to monitor groundwater levels and water quality in the water-table zone. Climatic data from Brunswick, Georgia, were used to calculate potential maximum recharge to the water-table zone on Jekyll Island. A weather station located on the island provided only precipitation data. Additional meteorological data from the island would enhance potential evapotranspiration estimates for recharge calculations. Groundwater levels and specific-conductance measurements showed the dependence of freshwater resources on rainfall to recharge the water-table zone of the surficial aquifer system and to influence groundwater flow on Jekyll Island. The unseasonably dry conditions during November 2012 to April 2013 induced saline water infiltration to the water-table zone from the marshland separating the Jekyll River from the island. A strong correlation (R 2 = 0.97) of specific conductance to chloride concentration in water samples from wells installed in the water-table zone provided support for the determination of seasonal directions of groundwater flow by confirming salinity changes in the water-table zone. Unseasonably wet conditions during the late spring to August caused groundwater-flow reversals in some areas. The high dependence of the water-table zone in the surficial aquifer system on precipitation to replenish the aquifer with freshwater underscored the importance of monitoring groundwater levels, water quality, and water use to identify aquifer-discharge conditions that have the potential to promote seawater encroachment and degrade freshwater resources on Jekyll Island.

Georgia↗

Groundwater conditions in Georgia, 2010–2011

The U.S. Geological Survey collects groundwater data and conducts studies to monitor hydrologic conditions, better define groundwater resources, and address problems related to water supply, water use, and water quality. In Georgia, water levels were monitored continuously at 186 wells during calendar year 2010 and at 181 wells during calendar year 2011. Because of missing data or short periods of record (less than 3 years) for several of these wells, a total of 168 wells are discussed in this report. These wells include 17 in the surficial aquifer system, 19 in the Brunswick aquifer system and equivalent sediments, 70 in the Upper Floridan aquifer, 16 in the Lower Floridan aquifer and underlying units, 10 in the Claiborne aquifer, 1 in the Gordon aquifer, 11 in the Clayton aquifer, 14 in the Cretaceous aquifer system, 2 in Paleozoic-rock aquifers, and 8 in crystalline-rock aquifers. Data from the well network indicate that water levels generally declined during the 2010 through 2011 calendar-year period, with water levels declining in 158 wells and rising in 10. Water levels declined over the period of record at 106 wells, increased at 56 wells, and remained relatively constant at 6 wells. In addition to continuous water-level data, periodic water-level measurements were collected and used to construct potentiometric-surface maps for the Upper Floridan aquifer in Camden, Charlton, and Ware Counties, Georgia, and adjacent counties in Florida during May–June 2010, and in the following areas in Georgia: the Brunswick area during August 2010 and August 2011, in the Albany–Dougherty County area during November 2010 and November 2011, and in the Augusta–Richmond County area during October 2010 and August 2011. In general, water levels in these areas were lower during 2011 than during 2010; however, the configuration of the potentiometric surfaces in each of the areas showed little change. Groundwater quality in the Floridan aquifer system is monitored in the Albany, Savannah, and Brunswick areas of Georgia. In the Albany area, nitrate as nitrogen concentrations in the Upper Floridan aquifer during 2011 generally decreased from 2010; however, concentrations in two wells remained above the U.S. Environmental Protection Agency (USEPA) 10-milligrams-per-liter (mg/L) drinking-water standard. In the Savannah area, specific conductance and chloride concentrations were measured in water samples from discrete depths in two wells completed in the Upper Floridan aquifer. Data from the two wells indicate that chloride concentrations in the Upper Floridan aquifer showed little change during calendar years 2010 through 2011 and remained below the 250 mg/L USEPA secondary drinking-water standard. During calendar years 2010 through 2011, chloride concentrations in the Lower Floridan aquifer increased slightly at Tybee Island and Skidaway Island, remaining above the drinking-water standard. In the Brunswick area, maps showing the chloride concentration of water in the Upper Floridan aquifer constructed using data collected from 32 wells during August 2010 and from 30 wells during August 2011 indicate that chloride concentrations remained above the USEPA secondary drinking-water standard in an approximately 2-square-mile area. During calendar years 2010 through 2011, chloride concentrations generally decreased in over 70 percent of the wells sampled during 2011, with a maximum decrease of 200 mg/L in a well located in the north-central part of the Brunswick area.

Georgia↗

Hydrologic conditions, groundwater quality, and analysis of sink hole formation in the Albany area of Dougherty County, Georgia, 2009

The U.S. Geological Survey, in cooperation with the Albany Water, Gas, and Light Commission has conducted water resources investigations and monitored groundwater conditions and availability in the Albany, Georgia, area since 1977. This report presents an overview of hydrologic conditions, water quality, and groundwater studies in the Albany area of Dougherty County, Georgia, during 2009. Historical data also are presented for comparison with 2009 data. During 2009, groundwater-level data were collected in 29 wells in the Albany area to monitor water-level trends in the surficial, Upper Floridan, Claiborne, Clayton, and Providence aquifers. Groundwater-level data from 21 of the 29 wells indicated an increasing trend during 2008–09. Five wells show no trend due to lack of data and three wells have decreasing trends. Period-of-record water levels (period of record ranged between 1957–2009 and 2003–2009) declined slightly in 10 wells and increased slightly in 4 wells tapping the Upper Floridan aquifer; declined in 1 well and increased in 2 wells tapping the Claiborne aquifer; declined in 4 wells and increased in 2 wells tapping the Clayton aquifer; and increased in 1 well tapping the Providence aquifer. Analyses of groundwater samples collected during 2009 from 12 wells in the Upper Floridan aquifer in the vicinity of a well field located southwest of Albany indicate that overall concentrations of nitrate plus nitrite as nitrogen increased slightly from 2008 in 8 wells. A maximum concentration of 12.9 milligrams per liter was found in a groundwater sample from a well located upgradient from the well field. The distinct difference in chemical constituents of water samples collected from the Flint River and samples collected from wells located in the well-field area southwest of Albany indicates that little water exchange occurs between the Upper Floridan aquifer and Flint River where the river flows adjacent to, but downgradient of, the well field. Water-quality data collected during 2008 from two municipal wells located in northern Albany and downgradient from a hazardous waste site indicate low-level concentrations of pesticides in one of the wells; however, no pesticides were detected in samples collected during 2009. Detailed geologic cross sections were used to create a three-dimensional, hydrogeologic diagram of the well field southwest of Albany in order to examine the occurrence of subsurface features conducive to sinkhole formation. Monitored groundwater-level data were used to assess the possible relations between sinkhole formation, precipitation, and water levels in the Upper Floridan aquifer. Although the water levels in well 12L382 oscillated above and below the top of the aquifer on a regular basis between 2007 and 2009, sinkhole development did not appear to correlate directly with either well-field pumping or water levels in the Upper Floridan aquifer. Specifically, two sinkholes formed in each of the years 2003 and 2005 when water levels were almost 20 feet above the top of the aquifer during most of the year. Water-level and sinkhole-formation data continue to be collected to allow further study and analysis.

Georgia↗

Hydrologic and water-quality conditions in the lower Apalachicola-Chattahoochee-Flint and parts of the Aucilla-Suwannee-Ochlockonee River basins in Georgia and adjacent parts of Florida and Alabama during drought conditions, July 2011

As part of the U.S. Department of the Interior sustainable water strategy, WaterSMART, the U.S. Geological Survey documented hydrologic and water-quality conditions in the lower Apalachicola-Chattahoochee-Flint and western and central Aucilla-Suwannee-Ochlockonee River basins in Alabama, Florida, and Georgia during low-flow conditions in July 2011. Moderate-drought conditions prevailed in this area during early 2011 and worsened to exceptional by June, with cumulative rainfall departures from the 1981-2010 climate normals registering deficits ranging from 17 to 27 inches. As a result, groundwater levels and stream discharges measured below median daily levels throughout most of 2011. Water-quality field properties including temperature, dissolved oxygen, specific conductance, and pH were measured at selected surface-water sites. Record-low groundwater levels measured in 12 of 43 surficial aquifer wells and 128 of 312 Upper Floridan aquifer wells during July 2011 underscored the severity of drought conditions in the study area. Most wells recorded groundwater levels below the median daily statistic, and 7 surficial aquifer wells were dry. Groundwater-level measurements taken in July 2011 were used to determine the potentiometric surface of the Upper Floridan aquifer. Groundwater generally flows to the south and toward streams except in reaches where streams discharge to the aquifer. The degree of connection between the Upper Floridan aquifer and streams decreases east of the Flint River where thick overburden hydraulically separates the aquifer from stream interaction. Hydraulic separation of the Upper Floridan aquifer from streams located east of the Flint River is shown by stream-stage altitudes that differ from groundwater levels measured in close proximity to streams. Most streams located in the study area during 2011 exhibited below normal flows (streamflows less than the 25th percentile), substantiating the severity of drought conditions that year. Streamflow and springflow measured at 202 sites along 2,122 stream miles during July 20-24, 2011, identified about 286 miles of losing streams, about 1,230 miles of gaining streams, and about 606 miles of streams with no flow. Water-quality field properties measured at 123 stream and 5 spring sites during July 2011 yielded water temperatures ranging from 20.6 to 31.6 degrees Celsius, dissolved oxygen ranging from 0.47 to 9.98 milligrams per liter, specific conductance ranging from 13 to 834 microsiemens per centimeter at 25 degrees Celsius, and pH ranging from 3.6 to 8.03.

Alabama, Florida, Georgia↗

Stream base flow and potentiometric surface of the Upper Floridan aquifer in south-Central and southwestern Georgia, November 2008

An investigation to document groundwater levels and stream base flow in the lower Chattahoochee-Flint and western and central Aucilla-Suwanee-Ochlockonee River basins during low-flow conditions was conducted by the U.S. Geological Survey in November 2008. During most of 2008, moderate to severe drought conditions prevailed throughout southwestern Georgia. Groundwater levels were below median daily levels throughout most of 2008; however, in some wells, groundwater levels rose to median daily levels by November. Discharge in most of the streams in the study area also had risen to median levels by November. The potentiometric surface of the Upper Floridan aquifer was constructed from water-level measurements collected in 21 counties from 376 wells during November 1-10, 2008. The potentiometric surface indicates that groundwater in the study area generally flows to the south and toward streams except in reaches discharging to the Upper Floridan aquifer. The degree of connection between the Upper Floridan aquifer and streams decreases east of the Flint River where the overburden is thicker. Decreased connectivity between ground and surface water is evident from the stream-stage altitudes measured in November 2008 east of the Flint River, which are not similar to water-level altitudes measured in the Upper Floridan aquifer. Stream-stage measurements were collected at 111 sites-26 U.S. Geological Survey streamgaging sites and 85 additional synoptic sites without gages. Streamflow measurements were made at 87 of the sites during November 2008 and were used to estimate base flow. The measurements indicate that stream reaches range from losing up to 10 cubic feet per second to gaining up to 4,559 cubic feet per second; five stream reaches were determined to be losing stream reaches. Of the 11 stream reaches in the Alapaha River subbasin, 7 were dry when measured in November 2008.

Georgia↗

Groundwater Conditions and Studies in the Albany Area of Dougherty County, Georgia, 2008

The U.S. Geological Survey has been working cooperatively with the Albany Water, Gas, and Light Commission to monitor groundwater quality and availability since 1977. This report presents an overview of groundwater conditions and studies in the Albany area of Dougherty County, Georgia, during 2008. Historical data also are presented for comparison with 2008 data. Ongoing monitoring activities include continuous water-level recording in 24 wells and periodic water-level measurements in 5 wells. During 2008, water levels in 10 of the continuous-recording wells were below normal, corresponding to lower than average rainfall. Groundwater samples collected from 25 wells in the Upper Floridan aquifer indicate that nitrate levels during 2008 were similar to values from 2007, with a maximum of 12.5 milligrams per liter at one well. Water samples collected from the Flint River and wells at the Albany well field were analyzed and plotted on a trilinear diagram to show the percent composition of selected major cations and anions. Groundwater constituents (major cations and anions) of the Upper Floridan aquifer at the Albany well field remain distinctly different from those in the water of the Flint River. To improve the understanding of the groundwater-flow system and nitrate movement in the Upper Floridan aquifer, the U.S. Geological Survey is developing a groundwater-flow model in the Albany area of southwestern Georgia. The model is being calibrated to simulate periods of dry (October 1999) hydrologic conditions. Preliminary results of particle tracking indicate that water flows to the well field from the northwest.

Georgia↗

Ground-Water Conditions and Studies in the Albany Area of Dougherty County, Georgia, 2007

The U.S. Geological Survey (USGS) has been working with the Albany Water, Gas, and Light Commission to monitor ground-water quality and availability since 1977. This report presents an overview of ground-water conditions and studies in the Albany area of Dougherty County, Georgia, during 2007. Historical data are also presented for comparison with 2007 data. Ongoing monitoring activities include continuous water-level recording in 24 wells and monthly water-level measurements in 5 wells. During 2007, water levels in 21 of the continuous-recording wells were below normal, corresponding to lower than average rainfall. Ground-water samples collected from the Upper Floridan aquifer indicate that nitrate levels have decreased or remained about the same since 2006. Water samples were collected from the Flint River and wells at the Albany wellfield, and data were plotted on a trilinear diagram to show the percent composition of selected major cations and anions. Ground-water constituents (major cations and anions) of the Upper Floridan aquifer at the Albany wellfield are distinctly different from those in the water of the Flint River. To improve the understanding of the ground-water flow system and nitrate movement in the Upper Floridan aquifer, the USGS is developing a ground-water flow model in the southwestern Albany area of Georgia. The model is being calibrated to simulate periods of dry (October 1999) and relatively wet (March 2001) hydrologic conditions. Preliminary water-level simulations indicate a generally good fit to measured water levels.

Georgia↗

U.S. Geological Survey Georgia Water Science Center and Albany Water, Gas, and Light Commission Cooperative Water Program— Summary of activities, July 2005 through June 2006

The U.S. Geological Survey (USGS) has been working with the Albany Water, Gas, and Light Commission to monitor ground-water quality and availability since 1977. This report presents the findings for July 2005 through June 2006 and summarizes the ground-water and surface-water conditions for 2005. Water levels in 14 wells were continuously monitored in Dougherty County, Georgia. Water levels in 12 of those wells were above normal, one was normal, and one was below normal. Ground-water samples collected from the Upper Floridan aquifer indicate that nitrate levels have increased in 13 wells and decreased in two wells from a year earlier. A sample also was collected from the Flint River. A trilinear diagram showing the percent composition of selected major cations and anions indicates that the ground-water quality of the Upper Floridan aquifer at the Albany wellfield is distinctly different from the water quality of the Flint River. To improve the understanding of the ground-water flow system and nitrate movement in the Upper Floridan aquifer, the USGS is developing a ground-water flow model in the southwest Albany area, Georgia.

Georgia↗