Search USGSSearch

Geology topics

D.V. Fitterman

Publications and source records attributed to D.V. Fitterman.

At least 19 recordsLinked to original sources

Electrical structure of Newberry Volcano, Oregon

From the interpretation of magnetotelluric, transient electromagnetic, and Schlumberger resistivity soundings, the electrical structure of Newberry Volcano in central Oregon is found to consist of four units. From the surface downward, the geoelectrical units are (1) very resistive, young, unaltered volcanic rock, (2) a conductive layer of older volcanic material composed of altered tuffs, (3) a thick resistive layer thought to be in part intrusive rocks, and (4) a lower-crustal conductor. This model is similar to the regional geoelectrical structure found throughout the Cascade Range. Inside the caldera, the conductive second layer corresponds to the steep temperature gradient and alteration minerals observed in the USGS Newberry 2 test hole. Drill hole information on the south and north flanks of the volcano (test holes GEO N-1 and GEO N-3, respectively) indicates that outside the caldera the conductor is due to alteration minerals (primarily smectite) and not high-temperature pore fluids. On the flanks of Newberry the conductor is generally deeper than inside the caldera, and it deepens with distance from the summit. A notable exception to this pattern is seen just west of the caldera rim, where the conductive zone is shallower than at other flank locations. The volcano sits atop a rise in the resistive layer, interpreted to be due to intrusive rocks. The intrusive material has served as a heat source to produce enhanced hydrothermal alteration and, perhaps in the case of the west-flank anomaly, elevated fluid temperatures. While no public drill hole information is available to confirm this hypothesis, the west-flank anomaly appears to be a good geothermal target. In addition to the possibility that a region on the west side of the volcano could be favorable for prospecting, part of the resistive structure under the center of the volcano could be due to a vapor-dominated environment with temperatures above 300°C. In other parts of the Cascades, pervasive alteration has produced mixed layer clays and zeolites, resulting in low-resistivity anomalies. Low resistivities cannot be assumed to indicate high-temperature pore fluids. The use of electrical methods that measure resistivity as a function of excitation frequency, such as spectral induced polarization, may provide a way of obtaining information about the type and extent of alteration.

Journal of Geophysical Research Solid Earth

Field Demonstrations of Five Geophysical Methods that Could Be Used to Characterize Deposits of Alluvial Aggregate

Personnel from the U.S. Geological Survey and Martin Marietta Aggregates, Inc., conducted field demonstrations of five different geophysical methods to show how these methods could be used to characterize deposits of alluvial aggregate. The methods were time-domain electromagnetic sounding, electrical resistivity profiling, S-wave reflection profiling, S-wave refraction profiling, and P-wave refraction profiling. All demonstrations were conducted at one site within a river valley in central Indiana, where the stratigraphy consisted of 1 to 2 meters of clay-rich soil, 20 to 35 meters of alluvial sand and gravel, 1 to 6 meters of clay, and multiple layers of limestone and dolomite bedrock. All geophysical methods, except time-domain electromagnetic sounding, provided information about the alluvial aggregate that was consistent with the known geology. Although time-domain electromagnetic sounding did not work well at this site, it has worked well at other sites with different geology. All of these geophysical methods complement traditional methods of geologic characterization such as drilling.

Scientific Investigations Report

Examples of transient sounding from groundwater exploration in sedimentary aquifers

Examples of the use of transient electromagnetic soundings for three ground-water exploration problems in sedimentary aquifers are given. The examples include: (1) estimating depths to water table and bedrock in an alluvium-filled basin, (2) mapping a confined fresh-water aquifer in bedrock sediments, and (3) locating a freshwater/salt-water interface in a glacial-outwash aquifer. The technique works quite well for these problems within the limitations imposed by the problem of equivalence. For thin conductive targets (S-equivalence) such as a salt-water lens, the ratio of the layer thickness to its resistivity can be determined, but not the individual layer parameters. The thickness of thin resistive zones (H-equivalence) can be resolved, but the resistivity of such layers is not well determined. The problem of H-equivalence is more severe than the S-equivalence. Equivalence imposes restrictions on the transient sounding method for some ground-water exploration problems. Model studies prior to field work can be used to assess the usefulness of the technique for a particular exploration objective.

Groundwater

Effect of bird maneuver on frequency-domain helicopter EM response

Bird maneuver, the rotation of the coil-carrying instrument pod used for frequency-domain helicopter electromagnetic surveys, changes the nominal geometric relationship between the bird-coil system and the ground. These changes affect electromagnetic coupling and can introduce errors in helicopter electromagnetic, (HEM) data. We analyze these effects for a layered half-space for three coil configurations: vertical coaxial, vertical coplanar, and horizontal coplanar. Maneuver effect is shown to have two components: one that is purely geometric and another that is inductive in nature. The geometric component is significantly larger. A correction procedure is developed using an iterative approach that uses standard HEM inversion routines. The maneuver effect correction reduces inversion misfit error and produces laterally smoother cross sections than obtained from uncorrected data.

Geophysics

The road to flamingo: An evaluation of flow pattern alterations and salinity intrusion in the lower glades, Everglades National Park

Introduction This report describes the history of roads through the Lower Glades of Everglades National Park, Florida and their influence on salinity intrusion. The chronology that lead to this work is interesting. The U.S. Geological Survey flew a series of helicopter electromagnetic surveys over portions of Everglades National Park to map saltwater intrusion starting in 1994 (Fitterman et al., 1995; Fitterman, 1996; Fitterman and Deszcz-Pan, 1998, 2002). These surveys identified variations in the electrical resistivity that were associated with changes in ground-water quality. The patterns of ground-water quality have been traced to natural saltwater intrusion, such as the effect of tidal rivers on lowering hydrologic heads far inland, and the influence of man-made structures, such as canals and roadways on surface water flow. These latter effects are of interest as they represent variations from the natural state of affairs in the park. Previous investigations had been done by Everglades National Park staff on the influence of some roads and canals on the near surface hydrology. This information was scattered through a number of National Park Service publications. In an effort to bring these materials together in an easily located reference, along with new data on flows through culverts beneath the main park road, this report was written.

Florida

Results of time-domain electromagnetic soundings in Everglades National Park, Florida

This report describes the collection, processing, and interpretation of time-domain electromagnetic soundings from Everglades National Park. The results are used to locate the extent of seawater intrusion in the Biscayne aquifer and to map the base of the Biscayne aquifer in regions where well coverage is sparse. The data show no evidence of fresh, ground-water flows at depth into Florida Bay.

Florida

Modeling of self-potential anomalies near vertical dikes

The self-potential (SP) Green's function for an outcropping vertical dike is derived from solutions for the dc resistivity problem for the same geometry. The Green's functions are numerically integrated over rectangular source regions on the contacts between the dike and the surrounding material to obtain the SP anomaly. The analysis is valid for thermoelectrical source mechanisms. Two types of anomalies can be produced by this geometry. When the two source planes are polarized in opposite directions, a monopolar anomaly is produced. This corresponds to the thermoelectrical properties of the dike being in contrast with the surrounding material. When the thermoelectric coefficients change monotonically across the dike, a dipolar anomaly is produced. In either case positive and negative anomalies are possible, and the greatest variation in potential will occur in the most resistive regions. Examples of the effect of changing different model parameters are given for sources that have constant intensity throughout the rectangular source regions. For these patch models the depth to the top of the source region is approximately equal to the distance between the minimum (or maximum) of the anomaly outside of the dike and the edge of the dike. Field data collected over a hot intrusive fissure are presented which have been modeled by the technique described.

Geophysics