Search USGSSearch

Geology topics

D.P. Brown

Publications and source records attributed to D.P. Brown.

3 recordsLinked to original sources

Location and site characteristics of the ambient ground-water-quality-monitoring network in West Virginia

Ground-water-quality-monitoring sites have been established in compliance with the 1991 West Virginia "Groundwater Protection Act." One of the provisions of the "Groundwater Protection Act" is to conduct ground-water sampling, data collection, analyses, and evaluation with sufficient frequency so as to ascertain the characteristics and quality of ground water and the sufficiency of the ground- water protection programs established pursuant to the act (Chapter 20 of the code of West Virginia, 1991, Article 5-M). Information for 26 monitoring sites (wells and springs) which comprise the Statewide ambient ground-water-quality-monitoring network is presented. Areas in which monitoring sites were needed were determined by the West Virginia Division of Environmental Protection, Office of Water Resources in consultation with the U.S. Geological Survey (USGS). Initial sites were chosen on the basis of recent hydrogeologic investigations conducted by the USGS and from data stored in the USGS Ground Water Site Inventory database. Land use, aquifer setting, and areal coverage of the State are three of the more important criteria used in site selection. A field reconnaissance was conducted to locate and evaluate the adequacy of selected wells and springs. Descriptive information consisting of site, geologic, well construction, and aquifer-test data has been compiled. The 26 sites will be sampled periodically for iron, manganese, most common ions (for example, calcium, magnesium, sodium, potassium, sulfate, chloride, bicarbonate), volatile and semivolatile organic compounds (for example, pesticides and industrial solvents), and fecal coliform and fecal streptococcus bacteria. Background information explaining ground-water systems and water quality within the State has been included.

Open-File Report

Hydrogeologic data from a test well in east-central Duval County, Florida

A 2,112-foot test well was drilled in east-central Duval County, Florida, to obtain geologic, hydrologic, and water chemistry data. Drill cuttings and water samples were collected, and water-level measurements and lithologic and geophysical logs were made. Deposits to a depth of 575 feet consist of sand, clayey sand, phosphatic sandy clay, coquina, sandy limestone, and dolostone. Below 575 feet, the deposits consist of fragmented and granular limestone, dolomitic limestone, and massive to finely crystalline dolostone, which comprise the Floridan aquifer system in the area. Water levels were measured near or at the bottom of the drill hole through the drill stem and in the annular space between the drilled hole and drill stem at the well head as drilling progressed from 770 to 2,112 feet in depth. Water levels measured through the drill stem ranged from 1.17 feet above land surface at a depth of 2,107 feet to 15.0 feet above land surface at a depth of 1,574 feet. Water levels measured in the annular space ranged from 7.5 feet above land surface at a depth of 770 feet to 14.9 feet at various depths from 1,574 to 1,721 feet. Chloride concentrations of water sampled through the drill stem from a depth of 711 to 1 ,616 feet ranged from 22 to 150 milligrams per liter at 1,648 feet. Chloride concentrations then ranged from 345 to about 800 milligrams per liter to a depth of 2,071 feet and then increased to a maximum of 5,450 milligrams per liter at 2,107 feet. (USGS)

Open-File Report

Effects of effluent spray irrigation on ground water at a test site near Tarpon Springs, Florida

Secondary-treated effluent was applied to a 7.2-acre test site near Tarpon Springs, Fla., for about 1 year at an average rate of 0.06 million gallons per day and 3 years at 0.11 million gallons per day. Chemical fertilizer was applied periodically to the test site and adjacent areas. Periodic mounding of the water table occurred due to effluent irrigation, inducing radial flow from the test site. Physical, geochemical, biochemical processes effectively reduced total nitrogen concentration 90% and total phosphorous concentration more than 95% in the ground water of the surficial aquifer about 300 feet downgradient from the test site from that of the applied effluent. Downgradient, total nitrogen averaged 2.4 milligrams per liter and total phosphorus averaged 0.17 milligrams per liter. Substantial increases in total phosphorus were observed when the pH of the ground water increased. Total coliform bacteria in the ground water of the surficial aquifer were generally less than 100 colonies per 100 milliliters. Fecal coliform bacteria were generally less than 25 colonies per 100 milliliters at the test site and were not detected downgradient or near the test site. Fecal streptococcal bacteria were generally less than 100 colonies per 100 milliliters at the test site, but were detected on three occasions near the test site. (USGS)

Open-File Report