Search USGSSearch

Geology topics

B. E. Jones

Publications and source records attributed to B. E. Jones.

8 recordsLinked to original sources

Results to be expected from resistivity‐measurements

The work described in this paper was all done in connection with dam‐site investigations and was not directly connected with hydrology. However, geophysics is coming to have a place in hydrologic investigations, and these results may throw some light on what can be accomplished by resistivity‐measurements. We have found that,for many questions not involving exact determinations of depth, resistivity‐ measurements give conclusive answers. Ordinarily a reliable answer can be expected to the question of the existence of a buried channel if the covering is composed of unconsolidated material with a resistivity differing from that of the rock. For example, topographic surveys were made at two alternative dam‐sites on a river about four miles apart. Examination of the surface‐geology indicated that a channel burled under glacial debris possibly existed at each site, but resistivity‐measurements proved that such a channel existed at one site and not at the other. On the other hand, at another site the geologist suspected there might be an old channel on a steep side hill. Geophysical measurements showed a depth of overburden of 46 feet and showed that if a deeper channel exists it must be narrow; but they did not show positively that no such channel exists. Probably a careful survey with a large number of lines would have given a more definite answer, but the rough topography interfered with the resistivity‐work, and time and money were not available for a detailed survey. After completion of the geophysical work, the geologist located some outcrops which led him to conclude that no old channel exists at this site. At two other dam‐sites in Oregon resistivity‐measurements showed that there were no burled channels.

Eos, Transactions, American Geophysical Union

Statistical evaluation of an inductively coupled plasma atomic emission spectrometric method for routine water quality testing

In an interlaboratory test, inductively coupled plasma atomic emission spectrometry (ICP-AES) was compared with flame atomic absorption spectrometry and molecular absorption spectrophotometry for the determination of 17 major and trace elements in 100 filtered natural water samples. No unacceptable biases were detected. The analysis precision of ICP-AES was found to be equal to or better than alternative methods. Known-addition recovery experiments demonstrated that the ICP-AES determinations are accurate to between plus or minus 2 and plus or minus 10 percent; four-fifths of the tests yielded average recoveries of 95-105 percent, with an average relative standard deviation of about 5 percent.

Applied Spectroscopy