Search USGS⌕ Search

Geology topics

Ashley R. Streig

Publications and source records attributed to Ashley R. Streig.

6 recordsLinked to original sources

The geologic history of the Chehalis Forearc Basin, Washington State, USA

The Chehalis basin is located between the Cascade arc and the Coast Range in southwest Washington State. It consists of sedimentary and volcanic rocks deposited throughout the Cenozoic and is underlain by the Siletzia terrane, a thick, large igneous province accreted in the Eocene. Here, we constrain evolution of the Chehalis basin depocenter using isochore maps derived from isostatic gravity anomalies, borehole data, and stratigraphy for several time periods: the Eocene (47.6–36.8 Ma), the Oligocene (36.8–20 Ma), and the Neogene (20–0 Ma). Our results suggest that local subsidence is driven by deformation on faults that bound and intersect the basin. We see northward depocenter migration, interpreted as a shift in deformation from the northwest striking Cedar Creek fault to the west striking Doty fault. We interpret these data in terms of the long-term north-south shortening and clockwise rotation of the Cascadia forearc. During the Eocene, the Cedar Creek fault was preferentially aligned with north-south shortening, but became less active when clockwise rotation brought the Doty fault into east-west alignment with the stress field. Sediment accumulation rates decreased from 196 m/Myr in the Paleogene (∼40–20 Ma) to 27 m/Myr in the Neogene (∼20–0 Ma) as Miocene uplift of the Coast Range limited accommodation space and shifted the depositional environment from marine to fluvial. Our results are consistent with the geologic evolution of the Portland and Tualatin basins to the south and reveal a depositional and structural history uniquely shaped by clockwise rotation of the Cascadia forearc.

Washington↗

The Mount Hood fault zone, active faulting at the crest of the dynamic Cascade Range, north-central Oregon, USA

The Mount Hood fault zone is a N-trending, ~55-km-long zone of active faulting along the western margin of the Hood River graben in north-central Oregon. The Mount Hood fault zone occurs along the crest of the Cascade Range and consists of multiple active fault segments. It is presently unclear how much Hood River graben extension is actively accommodated on the fault zone, and how Cascade intra-arc extension accommodates regional patterns of clockwise rotation and northwest translation of crustal blocks in the Pacific Northwest region of the United States. Evidence for Holocene activity on the Mount Hood fault zone was discovered in 2009 after acquisition of high-resolution lidar topography of the area. This trip will visit sites displaying evidence of Holocene surface rupture on fault strands within the Mount Hood fault zone. Day 1 starts with a two-hour drive from Portland to Mount Hood, a 3429-m-high glaciated active volcano, where we will visit sites south of the summit along the Twin Lakes fault segment, including several fault scarps and two sites where dating of offset buried soils constrains the timing of the most recent surface-rupturing event to the Holocene. Day 1 includes two hikes of ~1 km and will be partly cross-country. The trip will overnight at the historic Timberline Lodge, an architectural masterpiece from the Civilian Conservation Corps (1933–1942) era, located at tree line on the southern flank of Mount Hood. Day 2 will visit sites north of the summit, stopping along the Blue Ridge fault segment to view the site of 2011 paleoseismic trenches and an offset glacial moraine. We will visit an unusual uphill-facing scarp in coarse talus along the Gate Creek fault segment near the north end of the Mount Hood fault zone. We will conclude Day 2 with a short hike into the Mark O. Hatfield Wilderness along the Gate Creek fault segment to view evidence of a surface-rupturing earthquake that occurred only a few centuries ago, illuminated by a nearby paleoseismic trench hand-dug in 2020. Our neotectonic and paleoseismic data are among the first efforts to document and characterize seismic sources within the Mount Hood fault zone. However, even with our new age data, fault slip rates and earthquake recurrence remain poorly constrained. With our limited earthquake timing data, it is not clear whether all segments of the Mount Hood fault zone rupture together as a ≥ M 7 earthquake, or alternatively, if the fault segments rupture independently in a sequence of smaller ~M 6–sized events.

Oregon↗

An integrated feasibility study of reservoir thermal energy storage in Portland, Oregon, USA

In regions with long cold overcast winters and sunny summers, Deep Direct-Use (DDU) can be coupled with Reservoir Thermal Energy Storage (RTES) technology to take advantage of pre-existing subsurface permeability to save summer heat for later use during cold seasons. Many aquifers worldwide are underlain by permeable regions (reservoirs) containing brackish or saline groundwater that has limited beneficial use due to poor water quality. We investigate the utility of these relatively deep, slow flowing reservoirs for RTES by conducting an integrated feasibility study in the Portland Basin, Oregon, USA, developing methods and obtaining results that can be widely applied to groundwater systems elsewhere. As a case study, we have conducted an economic and social cost-benefit analysis for the Oregon Health and Science University (OHSU), a teaching hospital that is recognized as critical infrastructure in the Portland Metropolitan Area. Our investigation covers key factors that influence feasibility including 1) the geologic framework, 2) heat and fluid flow modeling, 3) capital and maintenance costs, 4) the regulatory framework, and 5) operational risks. By pairing a model of building seasonal heat demand with an integrated model of RTES resource supply, we determine that the most important factors that influence RTES efficacy in the study area are operational schedule, well spacing, the amount of summer heat stored (in our model, a function of solar array size), and longevity of the system. Generally, heat recovery efficiency increases as the reservoir and surrounding rocks warm, making RTES more economical with time. Selecting a base-case scenario, we estimate a levelized cost of heat (LCOH) to compare with other sources of heating available to OHSU and find that it is comparable to unsubsidized solar and nuclear, but more expensive than natural gas. Additional benefits of RTES include energy resiliency in the event that conventional energy supplies are disrupted (e.g., natural disaster) and a reduction in fossil fuel consumption resulting in a smaller carbon footprint. Key risks include reservoir heterogeneity and a possible reduction in permeability through time due to scaling (mineral precipitation). Lastly, a map of thermal energy storage capacity for the Portland Basin yields a total of 87,000 GWh, suggesting tremendous potential for RTES in the Portland Metropolitan Area.

Oregon↗

Neotectonic and paleoseismic analysis of the northwest extent of Holocene surface deformation along the Meers Fault, Oklahoma

TheMeers fault (Oklahoma) is one of fewseismogenic structures with evidence for Holocene surface rupture in the stable continental region of North America. The 37-kilometer-long southeast section of the full 54-kilometer-long Meers fault is interpreted to be Holocene active. The 17-kilometer-long northwest section is considered Quaternary active, but not Holocene active.We reevaluate surface expression and earthquake timing of the northwest Meers fault to improve seismic source characterization.We use airborne light detection and ranging and historical stereopaired aerial photos to evaluate the fault scarp and local faultzone geomorphology. In the northwest, complex surface deformation includes fault splays, subtle monoclinal warping, and a minor change in fault strike. We interpret that the alongstrike transition from surface faulting on the southeastMeers fault to surface folding on the northwest Meers fault occurs at the lithologic contact between Permian Post Oak conglomerate and Hennessey shale. We excavated a paleoseismic trench to evaluate the timing of surface-deforming earthquakes on the northwest section of the fault. The excavation revealed weathered Permian Hennessey shale and an ∼1–2-meter-thick veneer of Holocene alluvial deposits that were progressively deformed during two surface-folding earthquakes likely related to blind fault rupture beneath the site. Repeated onlapping to overlapping stratigraphic sequences and associated unconformities are intimately related to folding events along the monocline. OxCal paleoearthquake age modeling indicates that earthquakes occurred 4704–3109 yr B.P. and 5955–4744 yr B.P., and that part of the northwest section of the Meers fault is Holocene active. We find the Holocene-active section of the Meers fault should be lengthened 6.1 km to the northwest, to a total Holocene-active fault length of 43 km. Empirical scaling relationships between surface rupture length and magnitude reveal that the fault could generate an Mw 7.0 earthquake.

Oklahoma↗

Photomosaics and event evidence from the Frazier Mountain paleoseismic site, trench 1, cuts 5–24, San Andreas Fault Zone, southern California (2010–2012)

The Frazier Mountain paleoseismic site is located within the northern Big Bend of the southern San Andreas Fault (lat 34.8122° N., lon 118.9034° W.), in a small structural basin formed by the fault (fig. 1). The site has been the focus of over a decade of paleoseismic study due to high stratigraphic resolution and abundant dateable material. Trench 1 (T1) was initially excavated as a 50-m long, fault-perpendicular trench crossing the northern half of the basin (Lindvall and others, 2002; Scharer and others, 2014a). Owing to the importance of a high-resolution trench site at this location on a 200-km length of the fault with no other long paleoseismic records, later work progressively lengthened and deepened T1 in a series of excavations, or cuts, that enlarged the original excavation. Scharer and others (2014a) provide the photomosaics and event evidence for the first four cuts, which largely show the upper section of the site, represented by alluvial deposits that date from about A.D. 1500 to present. Scharer and others (2014b) discuss the earthquake evidence and dating at the site within the context of prehistoric rupture lengths and magnitudes on the southern San Andreas Fault. Here we present the photomosaics and event evidence for a series of cuts from the lower section, covering sediments that were deposited from about A.D. 500 to 1500 (fig. 2).

California↗

Photomosaics and event evidence from the Frazier Mountain paleoseismic site, trench 1, cuts 1–4, San Andreas Fault Zone, southern California (2007–2009)

The Frazier Mountain paleoseismic site is located at the northwest end of the Mojave section of the San Andreas Fault, in a small, closed depression at the base of Frazier Mountain near Tejon Pass, California (lat 34.8122° N., long 118.9034° W.). The site was known to contain a good record of earthquakes due to previous excavations by Lindvall and others (2002). This report provides data resulting from four nested excavations, or cuts, along trench 1 (T1) in 2007 and 2009 at the Frazier Mountain site. The four cuts were excavated progressively deeper and wider in an orientation perpendicular to the San Andreas Fault, exposing distal fan and marsh sediments deposited since ca. A.D. 1200. The results of the trenching show that earthquakes that ruptured the site have repeatedly produced a small depression or sag on the surface, which is subsequently infilled with sand and silt deposits. This report provides high-resolution photomosaics and logs for the T1 cuts, a detailed stratigraphic column for the deposits, and a table summarizing all of the evidence for ground rupturing paleoearthquakes logged in the trenches.

California↗