Search USGSSearch

Geology topics

Andrew J. Massey

Publications and source records attributed to Andrew J. Massey.

12 recordsLinked to original sources

Assessment of the presence of sewage in the Mill River under low-flow conditions, Springfield, Massachusetts, 2010–11

The U.S. Geological Survey, in cooperation with the Pioneer Valley Planning Commission, the U.S. Environmental Protection Agency, and the Massachusetts Department of Environmental Protection Senator William X. Wall Experiment Station, assessed the presence of 14 commonly used human-health pharmaceutical compounds, fecal indicator bacteria, and other man-made compounds indicative of the presence of human sewage in the lower reach of the Mill River near its confluence with the Connecticut River in Springfield, Massachusetts. The study was part of the Tri-State Connecticut River Targeted Watershed Initiative and involved the collection and analysis of raw river water at three sites along the reach, extending from Watershops Pond to the mouth, over the course of a low-flow period, July through November 2010. Previous studies in the region indicated that nonpoint or undocumented sources of wastewater contributed a variety of organic contaminants and potentially harmful bacteria to rivers under both high- and low-flow conditions. Additional samples, including a raw sewage sample collected near a Mill River combined sewer overflow during a non-overflow period, were collected in March 2011. The study was designed to determine if city sewage or other domestic sources of wastewater were entering the river within this reach during low-flow conditions. No definitive evidence of sewage was measured in Mill River water samples collected during the study period. Fecal indicator bacteria, including Escherichia coli ( E. coli ) and enterococci bacteria, were detected in all Mill River water samples. In the DNA analysis of enterococci cultures from the Mill River, samples generally tested negative for the Enterococcus faecium ( esp ) human-specific genetic marker, whereas the raw sewage sample tested positive. Samples also generally tested negative in the human-specific rDNA marker assay for the anaerobic bacterium Bacteroidetes . Samples tested negative in 2010 for two Bacteroidetes human-specific genetic markers, HF134 and HF183, except samples from near the mouth of the Mill River, which tested positive. Samples collected in March 2011 from all three measurement sites tested positive for both markers. The results of bacterial analyses suggest that the fecal bacteria in summer and fall months are most likely of animal origin rather than human. Despite the urban setting, long history of development, and many potential sources of man-made contamination in the Mill River, none of the 12 water samples collected during the study contained targeted pharmaceutical compounds at concentrations greater than the analytical reporting levels. Other man-made compounds, like fluorescent whitening agents, were measured and detected in samples at low concentrations 4 out of 5 times the samples were collected; however, the other lines of evidence do not support a sewer source but rather other nonpoint sources upstream in the watershed. The results of this study do not support the hypothesis that aging sewer lines or combined sewer overflow infrastructure leak into the Mill River as tested during the low-flow conditions during sampling for this study. None of the results from Mill River samples offer conclusive evidence of the presence of sewage. Some low-level detections of pharmaceutical compounds, other man-made chemicals, and bacteria suggest an upstream, nonpoint source. A single raw sewage sample was collected, diluted, and examined for comparison with Mill River water samples and to ensure that the analytical methods could detect typical wastewater constituents. High levels of bacteria were measured, and low levels of three anthropogenic pharmaceutical compounds were detected, confirming the effectiveness of the sub-part-per-million method. The concentration of fluorescent whitening agent-1 in the sewage sample was 90,000 times greater than the median concentration in the Mill River samples.

Massachusetts

The Surge, Wave, and Tide Hydrodynamics (SWaTH) network of the U.S. Geological Survey—Past and future implementation of storm-response monitoring, data collection, and data delivery

After Hurricane Sandy made landfall along the northeastern Atlantic coast of the United States on October 29, 2012, the U.S. Geological Survey (USGS) carried out scientific investigations to assist with protecting coastal communities and resources from future flooding. The work included development and implementation of the Surge, Wave, and Tide Hydrodynamics (SWaTH) network consisting of more than 900 monitoring stations. The SWaTH network was designed to greatly improve the collection and timely dissemination of information related to storm surge and coastal flooding. The network provides a significant enhancement to USGS data-collection capabilities in the region impacted by Hurricane Sandy and represents a new strategy for observing and monitoring coastal storms, which should result in improved understanding, prediction, and warning of storm-surge impacts and lead to more resilient coastal communities. As innovative as it is, SWaTH evolved from previous USGS efforts to collect storm-surge data needed by others to improve storm-surge modeling, warning, and mitigation. This report discusses the development and implementation of the SWaTH network, and some of the regional stories associated with the landfall of Hurricane Sandy, as well as some previous events that informed the SWaTH development effort. Additional discussions on the mechanics of inundation and how the USGS is working with partners to help protect coastal communities from future storm impacts are also included.

Connecticut, Delaware, Maine, Maryland, Massachuse

Tropical storm Irene flood of August 2011 in northwestern Massachusetts

A Presidential disaster was declared in northwestern Massachusetts, following flooding from tropical storm Irene on August 28, 2011. During the storm, 3 to 10 inches of rain fell on soils that were susceptible to flash flooding because of wet antecedent conditions. The gage height at one U.S. Geological Survey streamgage rose nearly 20 feet in less than 4 hours because of the combination of saturated soils and intense rainfall. On August 28, 2011, in the Deerfield and Hoosic River Basins in northwestern Massachusetts, new peaks of record were set at six of eight U.S. Geological Survey long-term streamgages with 46 to 100 years of record. Additionally, high-water marks were surveyed and indirect measurements of peak discharge were calculated at two discontinued streamgages in the Deerfield and Hoosic River Basins with 24 and 61 years of record, respectively. This data resulted in new historic peaks of record at the two discontinued streamgages from tropical storm Irene. Peak flows that resulted from tropical storm Irene (August 28, 2011) were determined at the U.S. Geological Survey streamgages by using stage-discharge rating curves and indirect computation methods. For six streamgages, indirect computation methods were used to compute the peak flows. Peak flows from tropical storm Irene had annual exceedance probabilities (AEPs) that ranged from 5.4 percent to less than 0.2 percent at 10 streamgages in northwestern Massachusetts. Discharges calculated for select AEPs as a part of this study were compared with discharges published for the same AEPs in the effective Federal Emergency Management Agency flood insurance studies (FISs) for communities in the study area. Discharges estimated for the 10-, 2-, 1-, and 0.2-percent AEPs at two streamgages on the main stem of the Deerfield River ranged from about 3 percent lower to 14 percent higher than discharges in the FISs. AEP discharges calculated for two streamgages on tributaries to the Deerfield River were 27 to 89 percent higher than the FISs. For the four streamgages in the Hoosic River Basin, the 10-, 2-, 1-, and 0.2-percent AEP discharges calculated ranged from about 33 percent lower to 5 percent higher than the FISs. The simulated 1-percent AEP discharge water-surface elevations (nonregulatory) from recent (2015–16) hydraulic models for river reaches in the study area, which include the Deerfield, Green, and North Rivers in the Deerfield River Basin and the Hoosic River in the Hoosic River Basin, were compared with water-surface profiles in the FISs. The water-surface elevation comparisons were generally done downstream and upstream from bridges, dams, and major tributaries. The simulated 1-percent AEP discharge water-surface elevations of the recent hydraulic studies averaged 2.2, 2.3, 0.3, and 0.7 ft higher than water-surface elevations in the FISs for the Deerfield, Green, North, and Hoosic Rivers, respectively. The differences in water-surface elevations between the recent (2015–16) hydraulic studies and the FISs likely are because of (1) improved land elevation data from light detection and ranging (lidar) data collected in 2012, (2) detailed surveying of hydraulic structures and cross sections throughout the river reaches in 2012–13 (reflecting structure and cross section changes during the last 30–35 years), (3) updated hydrology analyses (30–35 water years of additional peak flow data at streamgages), and (4) high-water marks from the 2011 tropical storm Irene flood being used for model calibration.

Massachusetts

Storm tide monitoring during the blizzard of January 26-28, 2015, in eastern Massachusetts

The U.S. Geological Survey (USGS) deployed a temporary monitoring network of six storm surge sensors and four barometric pressure sensors along the Atlantic coast in eastern Massachusetts, from Plymouth to Newburyport, before the blizzard of January 26–28, 2015 (Blizzard of January 2015), to record the timing and magnitude of storm tide at select locations where forecasters had predicted the potential for coastal flooding. Additionally, water-level data were recorded and transmitted in near real-time from four permanent USGS tidal stations—three on Cape Cod and one near the mouth of the Merrimack River in Newburyport. The storm surge sensors were deployed at previously established fixed sites outfitted with presurveyed mounting brackets. The mounting brackets were installed in 2014 as part of the USGS Surge, Wave, and Tide Hydrodynamic (SWaTH) Network ( https://water.usgs.gov/floods/STN/ ), which was funded through congressional supplemental appropriations for the U.S. Department of the Interior after the devastating landfall of Hurricane Sandy on October 29, 2012 (Simmons and others, 2014). The USGS received this funding to enable better understanding of coastal flooding hazards in the region, to improve preparedness for future coastal storms, and to increase the resilience of coastal cities, infrastructure, and natural systems in the region (Buxton and others, 2013). The USGS established 163 monitoring locations along the New England coast for the SWaTH Network, including 70 sites in Massachusetts. The Blizzard of January 2015 was a powerful and destructive storm that threatened public safety and led to widespread cancellations and delays at transportation hubs, schools, and businesses in Massachusetts, including, for example, the closure of General Edward Lawrence Logan (Boston-Logan) International Airport and cancellation of all flights on January 27 and a statewide travel ban issued for January 28. A total of 24.6 inches of snowfall and winds up to 45 miles per hour (mi/hr) were recorded at the airport. Several coastal communities were affected and experienced flooding, overwash, and damage to seawalls, dwellings, and other infrastructure. In Scituate, the National Guard was sent to rescue people from flooding, and power was cut to some areas of the town to prevent electrical fires.

Massachusetts

Determination of dilution factors for discharge of aluminum-containing wastes by public water-supply treatment facilities into lakes and reservoirs in Massachusetts

Dilution of aluminum discharged to reservoirs in filter-backwash effluents at water-treatment facilities in Massachusetts was investigated by a field study and computer simulation. Determination of dilution is needed so that permits for discharge ensure compliance with water-quality standards for aquatic life. The U.S. Environmental Protection Agency chronic standard for aluminum, 87 micrograms per liter (μg/L), rather than the acute standard, 750 μg/L, was used in this investigation because the time scales of chronic exposure (days) more nearly match rates of change in reservoir concentrations than do the time scales of acute exposure (hours). Whereas dilution factors are routinely computed for effluents discharged to streams solely on the basis of flow of the effluent and flow of the receiving stream, dilution determination for effluents discharged to reservoirs is more complex because (1), compared to streams, additional water is available for dilution in reservoirs during low flows as a result of reservoir flushing and storage during higher flows, and (2) aluminum removal in reservoirs occurs by aluminum sedimentation during the residence time of water in the reservoir. Possible resuspension of settled aluminum was not considered in this investigation. An additional concern for setting discharge standards is the substantial concentration of aluminum that can be naturally present in ambient surface waters, usually in association with dissolved organic carbon (DOC), which can bind aluminum and keep it in solution. A method for dilution determination was developed using a mass-balance equation for aluminum and considering sources of aluminum from groundwater, surface water, and filter-backwash effluents and losses caused by sedimentation, water withdrawal, and spill discharge from the reservoir. The method was applied to 13 reservoirs. Data on aluminum and DOC concentrations in reservoirs and influent water were collected during the fall of 2009. Complete reservoir volume was determined to be available for mixing on the basis of vertical and horizontal aluminum-concentration profiling. Losses caused by settling of aluminum were assumed to be proportional to aluminum concentration and reservoir area. The constant of proportionality, as a function of DOC concentration, was established by simulations in each of five reservoirs that differed in DOC concentration. In addition to computing dilution factors, the project determined dilution factors that would be protective with the same statistical basis (frequency of exceedance of the chronic standard) as dilutions computed for streams at the 7-day-average 10-year-recurrence annual low flow (the 7Q10). Low-flow dilutions are used for permitting so that receiving waters are protected even at the worst-case flow levels. The low-flow dilution factors that give the same statistical protection are the lowest annual 7-day-average dilution factors with a recurrence of 10 years, termed 7DF10s. Determination of 7DF10 values for reservoirs required that long periods of record be simulated so that dilution statistics could be determined. Dilution statistics were simulated for 13 reservoirs from 1960 to 2004 using U.S. Geological Survey Firm-Yield Estimator software to model reservoir inputs and outputs and present-day values of filter-effluent discharge and aluminum concentration. Computed settling velocities ranged from 0 centimeters per day (cm/d) at DOC concentrations of 15.5 milligrams per liter (mg/L) to 21.5 cm/d at DOC concentrations of 2.7 mg/L. The 7DF10 values were a function of aluminum effluent discharged. At current (2009) effluent discharge rates, the 7DF10 values varied from 1.8 to 115 among the 13 reservoirs. In most cases, the present-day (2009) discharge resulted in receiving water concentrations that did not exceed the standard at the 7DF10. Exceptions were one reservoir with a very small area and three reservoirs with high concentrations of DOC. Maximum permissible discharges were determined for water-treatment plants by adjusting discharges upward in simulations until the 7DF10 resulted in reservoir concentrations that just met the standard. In terms of aluminum flux, these discharges ranged from 0 to 28 kilograms of aluminum per day.

Massachusetts

Refinement and evaluation of the Massachusetts firm-yield estimator model version 2.0

The firm yield is the maximum average daily withdrawal that can be extracted from a reservoir without risk of failure during an extended drought period. Previously developed procedures for determining the firm yield of a reservoir were refined and applied to 38 reservoir systems in Massachusetts, including 25 single- and multiple-reservoir systems that were examined during previous studies and 13 additional reservoir systems. Changes to the firm-yield model include refinements to the simulation methods and input data, as well as the addition of several scenario-testing capabilities. The simulation procedure was adapted to run at a daily time step over a 44-year simulation period, and daily streamflow and meteorological data were compiled for all the reservoirs for input to the model. Another change to the model-simulation methods is the adjustment of the scaling factor used in estimating groundwater contributions to the reservoir. The scaling factor is used to convert the daily groundwater-flow rate into a volume by multiplying the rate by the length of reservoir shoreline that is hydrologically connected to the aquifer. Previous firm-yield analyses used a constant scaling factor that was estimated from the reservoir surface area at full pool. The use of a constant scaling factor caused groundwater flows during periods when the reservoir stage was very low to be overestimated. The constant groundwater scaling factor used in previous analyses was replaced with a variable scaling factor that is based on daily reservoir stage. This change reduced instability in the groundwater-flow algorithms and produced more realistic groundwater-flow contributions during periods of low storage. Uncertainty in the firm-yield model arises from many sources, including errors in input data. The sensitivity of the model to uncertainty in streamflow input data and uncertainty in the stage-storage relation was examined. A series of Monte Carlo simulations were performed on 22 reservoirs to assess the sensitivity of firm-yield estimates to errors in daily-streamflow input data. Results of the Monte Carlo simulations indicate that underestimation in the lowest stream inflows can cause firm yields to be underestimated by an average of 1 to 10 percent. Errors in the stage-storage relation can arise when the point density of bathymetric survey measurements is too low. Existing bathymetric surfaces were resampled using hypothetical transects of varying patterns and point densities in order to quantify the uncertainty in stage-storage relations. Reservoir-volume calculations and resulting firm yields were accurate to within 5 percent when point densities were greater than 20 points per acre of reservoir surface. Methods for incorporating summer water-demand-reduction scenarios into the firm-yield model were developed as well as the ability to relax the no-fail reliability criterion. Although the original firm-yield model allowed monthly reservoir releases to be specified, there have been no previous studies examining the feasibility of controlled releases for downstream flows from Massachusetts reservoirs. Two controlled-release scenarios were tested—with and without a summer water-demand-reduction scenario—for a scenario with a no-fail criterion and a scenario that allows for a 1-percent failure rate over the entire simulation period. Based on these scenarios, about one-third of the reservoir systems were able to support the flow-release scenarios at their 2000–2004 usage rates. Reservoirs with higher storage ratios (reservoir storage capacity to mean annual streamflow) and lower demand ratios (mean annual water demand to annual firm yield) were capable of higher downstream release rates. For the purposes of this research, all reservoir systems were assumed to have structures which enable controlled releases, although this assumption may not be true for many of the reservoirs studied.

Massachusetts

Pharmaceutical compounds in Merrimack River water used for public supply, Lowell, Massachusetts, 2008-09

This report presents results of a study conducted by the U.S. Geological Survey (USGS), in cooperation with the Massachusetts Department of Environmental Protection, to determine the occurrence of 14 commonly used human-health pharmaceutical compounds and fecal-indicator bacteria in Merrimack River water used as a drinking-water source by 135,000 residents in eastern Massachusetts. The study was designed to complement the USGS National Water-Quality Assessment Program's Source Water-Quality Assessment, which identifies patterns of occurrence of 280 primarily unregulated organic wastewater contaminants in source water used by community water systems and determines whether these patterns also occur in treated drinking water prior to distribution. The study involved periodic collection and analysis of raw Merrimack River water and treated drinking water over the course of 1 year. Water samples were collected periodically without regard to flow regime or antecedent weather conditions at the Lowell Regional Water Utility's Merrimack River intake upstream from Lowell, Mass. The same parcel of water was then sampled as finished water following treatment. Despite the presence of many potential sources of contamination in the drinking-water source area, only 2 of the 14 pharmaceutical analytes were detected at reportable concentrations in the source-water samples, and these occurred in only one set of periodic samples. Acetaminophen, a nonprescription analgesic, and caffeine were detected in the September source-water samples at concentrations of 0.084 and 0.068 micrograms per liter, respectively. Three other compounds-carbamazepine, an antiepileptic; cotinine, a metabolite of nicotine; and diphenhydramine, a nonprescription antihistamine-were detected in source-water samples, but at concentrations too low to be reliably quantified. None of the 14 pharmaceuticals was found in the finished water at a reportable concentration, defined as two times the long-term detection limit used by the analytical laboratory. In addition to the pharmaceutical analyses, measurements of fecal-indicator bacteria (Escherichia coli) concentrations and several physical characteristics were made on all source-water samples. Values for these constituents were consistently within State standards. It is possible that the monthly sampling schedule missed hydrologic events that would have transported greater concentrations of sewage contaminants to the sampling site, or that the large flow volume of the river at the study site effectively diluted the contaminant signal, but it is also likely that recent efforts to separate stormwater- and wastewater-discharge systems in the reaches upstream from the Lowell Regional Water Utility have greatly reduced the potential for sewage contamination at the intake.

Scientific Investigations Report

Hydrogeology and Simulation of Groundwater Flow in the Plymouth-Carver-Kingston-Duxbury Aquifer System, Southeastern Massachusetts

The glacial sediments that underlie the Plymouth-Carver-Kingston-Duxbury area of southeastern Massachusetts compose an important aquifer system that is the primary source of water for a region undergoing rapid development. Population increases and land-use changes in this area has led to two primary environmental effects that relate directly to groundwater resources: (1) increases in pumping that can adversely affect environmentally sensitive groundwater-fed surface waters, such as ponds, streams, and wetlands; and (2) adverse effects of land use on the quality of water in the aquifer. In response to these concerns, the U.S. Geological Survey, in cooperation with the Massachusetts Department of Environmental Protection, began an investigation in 2005 to improve the understanding of the hydrogeology in the area and to assess the effects of changing pumping and recharge conditions on groundwater flow in the Plymouth-Carver-Kingston-Duxbury aquifer system. A numerical flow model was developed based on the USGS computer program MODFLOW-2000 to assist in the analysis of groundwater flow. Model simulations were used to determine water budgets, flow directions, and the sources of water to pumping wells, ponds, streams, and coastal areas. Model-calculated water budgets indicate that approximately 298 million gallons per day (Mgal/d) of water recharges the Plymouth-Carver-Kingston-Duxbury aquifer system. Most of this water (about 70 percent) moves through the aquifer, discharges to streams, and then reaches the coast as surface-water discharge. Of the remaining 30 percent of flow, about 25 percent of the water that enters the aquifer as recharge discharges directly to coastal areas and 5 percent discharges to pumping wells. Groundwater withdrawals are anticipated to increase from the current (2005) rate of about 14 Mgal/d to about 21 Mgal/d by 2030. Pumping from large-capacity production wells decreases water levels and increases the potential for effects on surface-water bodies, which are affected by pumping and wastewater disposal locations and rates. Pumping wells that are upgradient of surface-water bodies potentially capture water that would otherwise discharge to these surface-water bodies, thereby reducing streamflow and pond levels. The areas most affected by proposed increases in groundwater withdrawals are in the Towns of Plymouth and Wareham where more than half of the proposed increase in pumping will occur. In response to an increase of about 7 Mgal/d of pumping, groundwater discharge to streams is reduced by about 6 cubic feet per second (ft3/s) (about 4 Mgal/d) from a total of about 325 ft3/s. Reduction in streamflow is moderated by an increase of artificial recharge from wastewater returned to the aquifer by onsite domestic septic systems and centralized wastewater treatment facilities. It is anticipated that about 3 Mgal/d of the 7 Mgal/d of increase in pumped water will be returned to the aquifer as wastewater by 2030. Currently (2005) about 3 percent of groundwater discharge to streams is from wastewater return flow to the aquifer during average conditions. During drought conditions, the component of streamflow augmented by wastewater return flow doubles as wastewater recharge remains constant and aquifer recharge rates decrease. Wastewater return flow, whether as direct groundwater discharge to streams or as an additional source of aquifer recharge, increases the height of the water table near streams, thereby moderating the effects of increased groundwater withdrawals on streamflow. An analysis of a simulated drought similar to the 1960s drought of record indicates that the presence of streams moderates the effects on water levels of reduced aquifer recharge. The area where water-table altitudes were least affected by drought was in the Weweantic River watershed in the Town of Carver. Water levels decreased by less than 2 feet from current average conditions compared to decreases of greater than 5

Scientific Investigations Report

Distribution and migration of ordnance-related compounds and oxygen and hydrogen stable isotopes in ground water near Snake Pond, Sandwich, Massachusetts

Explosive compounds, such as RDX (hexahydro-1,3,5-trinitro-1,3,5-triazine) and HMX (octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine), and the propellant compound perchlorate are present in ground water near Snake Pond, a ground-water flow-through glacial kettle pond in the glacial sand and gravel aquifer on western Cape Cod near Camp Edwards on the Massachusetts Military Reservation. The contaminants originate from the J-3 Range ordnance training and testing area. Ground-water samples were collected at 10 sites near the pond to determine the paths of the contaminants as they underflow or completely or partially discharge into the pond. Water-quality profiles were developed for sites on opposite ends of a 200-foot-long intermittent island near the northern, upgradient end of the pond by collecting water samples from two temporary drive-point borings. RDX was detected at both locations between 60 and 90 feet below the pond level. The highest RDX concentration was 0.99 micrograms per liter. Perchlorate was detected at only one location on the island, between 95 and 100 feet below the pond level at a concentration of 0.61 micrograms per liter. Profiles of oxygen and hydrogen stable isotopes were developed for seven sites spaced 300 to 600 feet apart along the southern, downgradient shore of the pond. A transition from heavier to lighter oxygen and hydrogen isotopes was observed at an altitude of about -50 feet. This transition most likely is the boundary between evaporation-affected pond water that is seeping into the aquifer and ground water that has passed beneath the pond. RDX was not detected in the ground-water samples collected south of the pond. Perchlorate was detected only in one sample from a shallow depth in one boring. The results of these analyses indicate that the J-3 Range plume contains low concentrations of RDX and perchlorate (less than 1 microgram per liter) as it passes beneath the northern end of Snake Pond. Results of ground-water-flow modeling indicate that ground water containing these low levels of RDX and perchlorate discharges into the pond south of the island. If the contaminated ground water should travel as far as the southern shore of the pond, it would be overlain near the shore by a zone of pond water seeping into the aquifer that is about 100 feet thick.

Massachusetts

Ground-water levels near the top of the water-table mound, western Cape Cod, Massachusetts, 2002-04

In January 2002 the U.S. Geological Survey began continuous water-level monitoring in three wells in the vicinity of the Southeast Ranges of Camp Edwards, near the Impact Area of the Massachusetts Military Reservation on Cape Cod. The purpose of this effort was to examine how water levels at sites with different unsaturated-zone thicknesses near the top of the water-table mound beneath western Cape Cod are affected by temporally variable recharge from precipitation, which is the sole source of water to the sand and gravel aquifer. The depths to water at the well sites are about 18, 30, and 101 feet below land surface. This report presents the first 3 years of water-level records and an estimate of aquifer recharge calculated from climatological measurements by the Jensen and Haise method and the Thornthwaite method. The water levels in the three wells varied temporally by about 4.5 feet during the study period. A comparison of the water levels with those measured in a nearby monitoring well with about 42 years of monthly measurements indicates that the 3-year monitoring period included the lowest water levels on western Cape Cod since the drought of the 1960's. The response of water levels to recharge was related to the depth to water. Water levels in the two wells with shallow depths to water responded quickly (within hours or days) to recharge, whereas the water-level response in the well with the greatest depth to water often lagged the recharge event by a month or more. The variations in the water levels among the wells changed as the location of the top of the water-table mound moved with the changing water-table altitude.

Massachusetts

Pushpoint sampling for defining spatial and temporal variations in contaminant concentrations in sediment pore water near the ground-water/surface-water interface

During four periods from April 2002 to June 2003, pore-water samples were taken from river sediment within a gaining reach (Mill Pond) of the Sudbury River in Ashland, Massachusetts, with a temporary pushpoint sampler to determine whether this device is an effective tool for measuring small-scale spatial variations in concentrations of volatile organic compounds and selected field parameters (specific conductance and dissolved oxygen concentration). The pore waters sampled were within a subsurface plume of volatile organic compounds extending from the nearby Nyanza Chemical Waste Dump Superfund site to the river. Samples were collected from depths of 10, 30, and 60 centimeters below the sediment surface along two 10-meter-long, parallel transects extending into the river. Twenty-five volatile organic compounds were detected at concentrations ranging from less than 1 microgram per liter to hundreds of micrograms per liter (for example, 1,2-dichlorobenzene, 490 micrograms per liter; cis-1,2-dichloroethene, 290 micrograms per liter). The most frequently detected compounds were either chlorobenzenes or chlorinated ethenes. Many of the compounds were detected only infrequently. Quality-control sampling indicated a low incidence of trace concentrations of contaminants. Additional samples collected with passive-water-diffusion-bag samplers yielded results comparable to those collected with the pushpoint sampler and to samples collected in previous studies at the site. The results demonstrate that the pushpoint sampler can yield distinct samples from sites in close proximity; in this case, sampling sites were 1 meter apart horizontally and 20 or 30 centimeters apart vertically. Moreover, the pushpoint sampler was able to draw pore water when inserted to depths as shallow as 10 centimeters below the sediment surface without entraining surface water. The simplicity of collecting numerous samples in a short time period (routinely, 20 to 30 per day) validates the use of a pushpoint sampler as a highly effective tool for mapping the extent of contaminated subsurface plumes, determining their constituents and loadings, and performing technical studies that may be relevant to bioremediation and other activities.

Massachusetts

Field tests of nylon-screen diffusion samplers and pushpoint samplers for detection of metals in sediment pore water, Ashland and Clinton, Massachusetts, 2003

Efficient and economical screening methods are needed to detect and to determine the approximate concentrations of potentially toxic trace-element metals in shallow groundwater- discharge areas (pore water) where the metals may pose threats to aquatic organisms; such areas are likely to be near hazardous-waste sites. Pushpoint and nylon-screen diffusion samplers are two complementary options for use in such environments. The pushpoint sampler, a simple well point, is easy to insert manually and to use. Only 1 day is required to collect samples. The nylon-screen diffusion sampler is well suited for use in sediments that do not allow a pump to draw water into a pushpoint sampler. In this study, both types of devices were used in sediments suitable for the use of the pushpoint sampler. Sampling with the nylon-screen diffusion sampler requires at least two site visits: one to deploy the samplers in the sediment, and a second to retrieve the samplers and collect the samples after a predetermined equilibration period. Extensive laboratory quality-control studies, field testing, and laboratory analysis of samples collected at the Nyanza Chemical Waste Dump Superfund site along the Sudbury River in Ashland, Massachusetts, and at a Superfund site-assessment location on Rigby Brook in Clinton, Massachusetts, indicate that these two devices yield comparable results for most metals and should be effective tools for pore-water studies. The nylon-screen diffusion samplers equilibrated within 1-2 days in homogeneous, controlled conditions in the laboratory. Nylon-screen diffusion samplers that were not purged of dissolved oxygen prior to deployment yielded results similar to those that were purged. Further testing of the nylon-screen diffusion samplers in homogeneous media would help to resolve any ambiguities about the data variability from the field studies. Comparison of data from replicate samples taken in both study areas shows that even samples taken from sites within a half-meter radius of one another have distinct differences in pore-water trace-element concentrations. Sequential replicate samples collected with the pushpoint sampler yield consistent results; moving the pushpoint sampler even 5 to 10 centimeters, however, generally produces a second set of data that differs enough from the first set of data to indicate a heterogeneous environment. High concentration biases for barium and zinc in laboratory and field samples collected with nylon-screen diffusion samplers, however, may make their use inappropriate for studies of these metals. Analyzing samples with high iron concentrations required sample dilution by factors of 2 or 10. Because these dilutions caused increases in the reporting levels by the same proportion, a substantial fraction of the data was censored. The results from undiluted samples, however, indicate that both devices should be useful for sampling ground water with metal concentrations close to reporting limits.

Scientific Investigations Report