Search USGSSearch

Geology topics

Adam J. Siade

Publications and source records attributed to Adam J. Siade.

4 recordsLinked to original sources

Feasibility and potential effects of the proposed Amargosa Creek Recharge Project, Palmdale, California

Historically, the city of Palmdale and vicinity have relied on groundwater as the primary source of water, owing, in large part, to the scarcity of surface water in the region. Despite recent importing of surface water, groundwater withdrawal for municipal, industrial, and agricultural use has resulted in groundwater-level declines near the city of Palmdale in excess of 200 feet since the early 1900s. To meet the growing water demand in the area, the city of Palmdale has proposed the Amargosa Creek Recharge Project (ACRP), which has a footprint of about 150 acres along the Amargosa Creek 2 miles west of Palmdale, California. The objective of this study was to evaluate the long-term feasibility of recharging the Antelope Valley aquifer system by using infiltration of imported surface water from the California State Water Project in percolation basins at the ACRP. Three monitoring sites were constructed, and geophysical surveys (gravity, seismic, and resistivity) were completed to define the thickness of valley-fill deposits, depth to water, and location of faults that could influence groundwater flow. Data collected at the monitoring sites, and results from the geophysical surveys, were used to identify three northwest-southeast trending faults in the vicinity of the proposed recharge facility; these faults are probably related to the nearby San Andreas fault zone. Water levels collected from wells at the monitoring sites showed water-level altitude differences as much as 230 feet between the upgradient and downgradient sides of the faults, indicating that these faults are barriers to groundwater flow. Lithologic and geophysical logs indicated the presence of a coarse gravel and sand unit extending from land surface to about 150 feet below land surface that did not appear to be disrupted by faulting. Water samples collected from the monitoring wells were analyzed for major ions, nutrients, trace elements, dissolved organic carbon, volatile organic compounds, stable isotopes of oxygen (oxygen-18) and hydrogen (hydrogen-2, or deuterium), and the radioactive isotopes of hydrogen (hydrogen-3, or tritium) and carbon (carbon-14, or 14 C) to determine the water quality of the aquifer system and to help determine the source and age of the groundwater. Results of the water-quality analysis indicated that the source of natural recharge is Amargosa Creek near the ACRP, but that the creek does not provide modern-day recharge downstream of the ACRP. Potential effects of artificial recharge at the ACRP were evaluated by using a local-scale model of groundwater flow. On the basis of geologic samples collected during drilling, the hydraulic conductivity of the sand and gravel unit in the upper 150 feet was assumed to range from 10 to 100 feet per day. To address the goal of minimizing the potential for liquefaction during an earthquake from water-table rise associated with groundwater recharge at the ACRP, simulated water levels were constrained to remain at least 50 feet below land surface, except beneath the proposed artificial-recharge facility. The hydraulic conductivities of faults were estimated on the basis of water-level data and an estimate of natural recharge along Amargosa Creek. With assumed horizontal hydraulic conductivities of 10 and 100 feet per day in the upper 150 feet, the simulated maximum artificial recharge rates to the regional flow system at the ACRP were 3,400 and 9,400 acre-feet per year, respectively. These maximum recharge rates were limited primarily by the horizontal hydraulic conductivity in the upper 150 feet and by the liquefaction constraint. Future monitoring of water-level and soil-water content changes during the proposed project would allow improved estimation of aquifer hydraulic properties, the effect of the faults on groundwater movement, and the overall recharge capacity of the ACRP.

California

Natural recharge estimation and uncertainty analysis of an adjudicated groundwater basin using a regional-scale flow and subsidence model (Antelope Valley, California, USA)

Groundwater has provided 50–90 % of the total water supply in Antelope Valley, California (USA). The associated groundwater-level declines have led the Los Angeles County Superior Court of California to recently rule that the Antelope Valley groundwater basin is in overdraft, i.e., annual pumpage exceeds annual recharge. Natural recharge consists primarily of mountain-front recharge and is an important component of the total groundwater budget in Antelope Valley. Therefore, natural recharge plays a major role in the Court’s decision. The exact quantity and distribution of natural recharge is uncertain, with total estimates from previous studies ranging from 37 to 200 gigaliters per year (GL/year). In order to better understand the uncertainty associated with natural recharge and to provide a tool for groundwater management, a numerical model of groundwater flow and land subsidence was developed. The transient model was calibrated using PEST with water-level and subsidence data; prior information was incorporated through the use of Tikhonov regularization. The calibrated estimate of natural recharge was 36 GL/year, which is appreciably less than the value used by the court (74 GL/year). The effect of parameter uncertainty on the estimation of natural recharge was addressed using the Null-Space Monte Carlo method. A Pareto trade-off method was also used to portray the reasonableness of larger natural recharge rates. The reasonableness of the 74 GL/year value and the effect of uncertain pumpage rates were also evaluated. The uncertainty analyses indicate that the total natural recharge likely ranges between 34.5 and 54.3 GL/year.

California

Groundwater-flow and land-subsidence model of Antelope Valley, California

Antelope Valley, California, is a topographically closed basin in the western part of the Mojave Desert, about 50 miles northeast of Los Angeles. The Antelope Valley groundwater basin is about 940 square miles and is separated from the northern part of Antelope Valley by faults and low-lying hills. Prior to 1972, groundwater provided more than 90 percent of the total water supply in the valley; since 1972, it has provided between 50 and 90 percent. Most groundwater pumping in the valley occurs in the Antelope Valley groundwater basin, which includes the rapidly growing cities of Lancaster and Palmdale. Groundwater-level declines of more than 270 feet in some parts of the groundwater basin have resulted in an increase in pumping lifts, reduced well efficiency, and land subsidence of more than 6 feet in some areas. Future urban growth and limits on the supply of imported water may increase reliance on groundwater. In 2011, the Los Angeles County Superior Court of California ruled that the Antelope Valley groundwater basin is in overdraft—groundwater extractions are in excess of the Court-defined safe yield of the groundwater basin. The Court determined that the safe yield of the adjudicated area of the basin was 110,000 acre-feet per year (acre-ft/yr). Natural recharge is an important component of total groundwater recharge in Antelope Valley; however, the exact quantity and distribution of natural recharge, primarily in the form of mountain-front recharge, is uncertain, with total estimates ranging from 30,000 to 160,000 acre-ft/yr. Technical experts, retained by parties to the adjudication, used 60,000 acre-ft/yr to estimate the sustainable yield of the basin, and this value was used in this study. In order to better understand the uncertainty associated with natural recharge and to provide a tool to aid in groundwater management, a numerical model of groundwater flow and land subsidence in the Antelope Valley groundwater basin was developed using old and new geohydrologic information. The groundwater-flow system consists of three aquifers: the upper, middle, and lower aquifers. The three aquifers, which were identified on the basis of the hydrologic properties, age, and depth of the unconsolidated deposits, consist of gravel, sand, silt, and clay alluvial deposits and clay and silty clay lacustrine deposits. Prior to groundwater development in the valley, recharge was primarily the infiltration of runoff from the surrounding mountains. Groundwater flowed from the recharge areas to discharge areas around the playas where it discharged from the aquifer system as either evapotranspiration or from springs. Partial barriers to horizontal groundwater flow, such as faults, have been identified in the groundwater basin. Water-level declines owing to groundwater development have eliminated the natural sources of discharge, and pumping for agricultural and urban uses have become the primary source of discharge from the groundwater system. Infiltration of return flow from agricultural irrigation has become an important source of recharge to the aquifer system. The groundwater-flow model of the basin was discretized horizontally into a grid of 130 rows and 118 columns of square cells 1 kilometer (0.621 mile) on a side, and vertically into four layers representing the upper (two layers), middle (one layer), and lower (one layer) aquifers. Faults that were thought to act as horizontal-flow barriers were simulated in the model. The model was calibrated to simulate steady-state conditions, represented by 1915 water levels and transient-state conditions during 1915–95, by using water-level and subsidence data. Initial estimates of the aquifer-system properties and stresses were obtained from a previously published numerical model of the Antelope Valley groundwater basin; estimates also were obtained from recently collected hydrologic data and from results of simulations of groundwater-flow and land-subsidence models of the Edwards Air Force Base area. Some of these initial estimates were modified during model calibration. Groundwater pumpage for agriculture was estimated on the basis of irrigated crop acreage and crop consumptive-use data. Pumpage for public supply, which is metered, was compiled and entered into a database used for this study. Estimated annual agricultural pumpage peaked at 395,000 acre-feet (acre-ft) in 1951 and then declined because of declining agricultural production. Recharge from irrigation return flows was assumed to be 30 percent of agricultural pumpage; delays associated with return flow moving through the unsaturated zone were also simulated. The annual quantity of mountain-front recharge initially was based on estimates from previous studies. The model was calibrated using the PEST software suite; prior information from the area was incorporated through the use of Tikhonov regularization. During model calibration, the estimated mountain-front recharge was reduced from the previous estimate of 30,300 acre-ft/yr to 29,150 acre-ft/yr. Results of the simulations using the calibrated model indicate that simulated groundwater pumpage exceeded recharge in most years, resulting in an estimated cumulative depletion in groundwater storage of 8,700,000 acre-ft during the transient-simulation period (1915–2005). About 15,000,000 acre-ft of cumulative groundwater pumpage was simulated during the transient-simulation period (1915–2005), reaching a maximum rate of about 400,000 acre-ft/yr in 1951. Groundwater pumpage resulted in simulated hydraulic heads declining by more than 150 feet (ft) compared to 1915 conditions in agricultural areas. The decline in hydraulic head in the groundwater basin is the result of this depletion of groundwater storage. In turn, the simulated decline in hydraulic head in the groundwater basin has resulted in the decrease in natural discharge from the basin and has caused compaction of aquitards, resulting in land subsidence. The areal distribution of total simulated land subsidence for 2005, after about 90 years of groundwater development, indicates that land subsidence occurred throughout almost the entire Lancaster subbasin, with a maximum of about 9.4 ft in the central and eastern parts of the subbasin. An important objective of this study was to systematically address the uncertainty in estimates of natural recharge and related aquifer parameters by using the groundwater-flow and land-subsidence model with observational data and expert knowledge. After the model was calibrated to the observations and a reasonable parameter set obtained, the parameter null space—parameter values that do not appreciably affect the model calibration but may have importance for prediction—was identified. The effect of parameter uncertainty on the estimation of mountain-front recharge was addressed using the Null-Space Monte Carlo method. The Pareto trade-off method of visualizing uncertainty was also used to portray the reasonableness of larger natural-recharge rates. Results indicate that the total mountain-front recharge likely ranges between 28,000 and 44,000 acre-ft/yr, which is appreciably less than published estimates of 60,000 acre-ft/yr. Additionally, expected errors associated with agricultural pumpage estimates used in this study were found to have relatively little effect on the estimates of mountain-front recharge, reflecting the difficulty in increasing recharge through manipulation of other components of the water budget. The calibrated model was used to simulate the response of the aquifer to potential future pumping scenarios: (1) no change in the distribution of pumpage, or status quo; (2) redistribution of pumpage; and (3) artificial recharge. All three of these scenarios specify a total pumpage throughout the Antelope Valley of 110,000 acre-ft/yr according to the safe yield value ruled by the Los Angeles County Superior Court of California. This reduction in groundwater pumpage is assumed uniform throughout the basin, based on a 10-percent reduction of the total pumpage in 2005 to achieve the 110,000 acre-ft/yr level. The calibrated Antelope Valley groundwater-flow and land-subsidence model was used to simulate the hydrologic effects of the three groundwater-management scenarios during a 50-year period by using the reduced, temporally constant, pumpage distribution. Results from the first scenario indicated that the total drawdown observed since predevelopment would continue, with values exceeding 325 ft near Palmdale; consequently, land subsidence would also continue, with additional subsidence (since 2005) exceeding 3 ft in the central part of the Lancaster subbasin. The second scenario evaluated redistributing pumpage from areas in the Lancaster subbasin where simulated hydraulic-head declines were the greatest to areas where declines were smallest. Neither a formal optimization algorithm nor water-rights allocations were considered when redistributing the pumpage. Results indicated that hydraulic heads near Palmdale, where the pumpage was reduced, would recover by about 200 ft compared to 2005 conditions, with only 30 ft of additional drawdown in the northwestern part of the Lancaster subbasin, where the pumpage was increased. The magnitude of the simulated additional land subsidence decreased slightly compared to the first, status quo, scenario but land subsidence continued to be simulated throughout most of the northern part of the Lancaster subbasin. The third scenario consisted of two artificial-recharge simulations along the Upper Amargosa Creek channel and at a site located north of Antelope Buttes. Results indicate that applying artificial recharge at these sites would yield continued drawdowns and associated land subsidence. However, the magnitudes of drawdown and subsidence would be smaller than those simulated in the status quo scenario, indicating that artificial-recharge operations in the Antelope Valley could be expected to reduce the magnitude and extent of continued water-level declines and associated land subsidence.

California

Stratigraphic controls on seawater intrusion and implications for groundwater management, Dominguez Gap area of Los Angeles, California, USA

Groundwater pumping has led to extensive water-level declines and seawater intrusion in coastal Los Angeles, California (USA). A SUTRA-based solute-transport model was developed to test the hydraulic implications of a sequence-stratigraphic model of the Dominguez Gap area and to assess the effects of water-management scenarios. The model is two-dimensional, vertical and follows an approximate flow line extending from the Pacific Ocean through the Dominguez Gap area. Results indicate that a newly identified fault system can provide a pathway for transport of seawater and that a stratigraphic boundary located between the Bent Spring and Upper Wilmington sequences may control the vertical movement of seawater. Three 50-year water-management scenarios were considered: (1) no change in water-management practices; (2) installation of a slurry wall; and (3) raising inland water levels to 7.6 m above sea level. Scenario 3 was the most effective by reversing seawater intrusion. The effects of an instantaneous 1-m sea-level rise were also tested using water-management scenarios 1 and 3. Results from two 100-year simulations indicate that a 1-m sea-level rise may accelerate seawater intrusion for scenario 1; however, scenario 3 remains effective for controlling seawater intrusion.

Hydrogeology Journal